User manual TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705. We hope that this TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705.


Mode d'emploi TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705
Download
Manual abstract: user guide TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com IMPORTANT!!!UC1 BOARD VERSION X. 06 UPDATES NEW X. 06 VERSION UC1 BOARD FEATURES IMPORTANT: This upgraded circuit board features: A new #6 power LED Constant red when 115 VAC is supplied to L & N. A new color for the #2 LED Constant blue when fan prover safety circuit is closed. A revised #5 LED With no call for heat present, flashes 3 seconds on / 3 seconds off if microcontroller is working properly. New LED # 6 RED 115V power supplied to UC1 L & N terminals P1 P2 C GND F LED 6 (RED) POWER LED (1 9) LED # 2 now BLUE (previously GREEN) LED # 5 RED With no call for heat, flashes 3 seconds on / 3 seconds off if microcontroller is working properly. LED 1 (AMBER) LED 2 (BLUE) LED 3 (GREEN) LED 4 (RED) LED 5 (RED) DRY 24 V 115 V J1 J2 XL XN N M MTR APPLIANCE INTERLOCK RELAY VENTER MOTOR RELAY AB 1 2 3 4 LN IMPORTANT: For 950-8804 UC1 Replacement Board Kits: If this is a 950-8804 UC1 board kit and you are replacing an existing UC1 board with this new board, note Dip Switch settings on existing UC1 circuit board so that those same settings can be positioned on this replacement circuit board. [. . . ] IMPORTANT: Remove J1 & J2 Call Jumper on UC1 to avoid backfeeds or short circuits. Connect T87 or Equivalent non-powered thermostat to A and B terminals on UC1. Remove T T Jumper from R8184 or equivalent Primary Control. Connect #3 on UC1 terminal block to T terminal of Primary Control. Connect #4 on UC1 terminal block to remaining T terminal of Primary Control. Connect 115 VAC supply voltage to L & N terminals on UC1. Installer must supply overload and disconnect protection. Crimp Ground wire to grounding spade in SS1 electrical box. Make sure RED voltage jumper on UC1 is on DRY. NOTE: If burner safety control goes out on lockout, the SideShot will continue to run as long as a call for heat is present. SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A HONEYWELL R8184 SERIES OR EQUIVALENT PRIMARY CONTROL AND A BURNER MOTOR POST-PURGE CONNECT TO L1 OR B1 BLACK ORANGE WHITE THERMOSTAT B O W T T F 115V DRY 24V F HONEYWELL R8184 SERIES OR EQUIVALENT J2 UNIVERSAL CONTROL IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. CALL JUMPER J1 CONNECT TO L2 OR B2 OIL VALVE SUPPLY 115 VAC 50/60 Hz GROUND LEGEND: 115 VAC D/N 9183047-4 10/16/03 XL XN N M MTR BURNER MOTOR IGNITION TRANS VENTER MOTOR IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. Separate the burner motor wire and ignition transformer from the Orange wire of R8184. Connect the Orange of R8184 to #1 on UC1 terminal block. Connect #2 on UC1 terminal block to White on R8184 and L2 or B2. Connect the HOT wire of oil solenoid valve to #4 on UC1 terminal block and neutral wire to White or N. Connect burner motor and ignition transformer HOT wires to M terminal on UC1 and neutrals to White or N. Connect 115 VAC supply voltage to L & N terminals on UC1. Installer must supply overload and disconnect protection. Crimp ground wire to grounding spade in SS1 electrical box. Make sure RED voltage jumper on UC1 is on 115V. 15 SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A SINGLE ZONE 24 VAC THERMOSTAT IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. THERMOSTAT Y R G R C J1 Y W INTERNAL CONTROL OF FURNACE SUPPLY 115 VAC 50/60 Hz R 115V DRY 24V W G J2 XL XN UNIVERSAL CONTROLLER CALL JUMPER LEGEND: 115 VAC 24 VAC D/N 9183046-5 GROUND IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. Connect W from t-stat to #1 on terminal block of UC1. Connect #2 on UC1 terminal block to C on internal control terminal strip of furnace/boiler. [. . . ] Proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under two years. All receipts should include the date code of the SideShot to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 1. ) Follow troubleshooting guide to determine defective component. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504102 REV D 0705 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag