User manual TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204. We hope that this TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204.


Mode d'emploi TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204
Download
Manual abstract: user guide TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204

Detailed instructions for use are in the User's Guide.

[. . . ] C 02/04 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com VERSION X. 04 INCLUDES NEW UC1 UNIVERSAL CONTROL MODEL SS1C INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important Safety Information! OWNER INSTRUCTIONS, DO NOT DESTROY NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 301oC (575oF) AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] Connect #4 on UC1 terminal block to W on internal control terminal strip of furnace/boiler. Connect 115 VAC supply voltage to L & N terminals on UC1. Installer must supply overload and disconnect protection. Crimp ground wire to grounding spade in SS1C electrical box. Make sure RED voltage jumper on UC1 is on 24V. NOTE: If burner primary control goes out on lockout, the SideShot will continue to run as long as a call for heat is present. SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED TO AN OIL-FIRED FURNACE WITH A HONEYWELL T87 OR EQUIVALENT NON-POWERED THERMOSTAT IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. HONEYWELL T87 OR EQUIVALENT NON-POWERED THERMOSTAT 115V DRY 24V PRIMARY CONTROL BLACK FACTORYWIRED ORANGE WHITE B O F W F T T SUPPLY 115 VAC 50/60 Hz R IMPORTANT: REMOVE JUMPER TO AVOID BACKFEEDS OR SHORT CIRCUITS. J2 J1 XL XN UNIVERSAL CONTROLLER LEGEND: 115 VAC LOW VAC 5 VDC BOARD-GENERATED POWER. DO NOT SUPPLY POWER! D/N 9183047-1 HONEYWELL R8184 SERIES OR EQUIVALENT GROUND IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. IMPORTANT: Remove J1 & J2 Call Jumper on UC1 to avoid backfeeds or short circuits. Connect T87 or Equivalent non-powered thermostat to A and B terminals on UC1. Remove T T Jumper from R8184 or equivalent Primary Control. Connect #3 on UC1 terminal block to T terminal of Primary Control. Connect #4 on UC1 terminal block to remaining T terminal of Primary Control. Connect 115 VAC supply voltage to L & N terminals on UC1. Installer must supply overload and disconnect protection. Crimp Ground wire to grounding spade in SS1C electrical box. Make sure RED voltage jumper on UC1 is on DRY. NOTE: If burner safety control goes out on lockout, the SideShot will continue to run as long as a call for heat is present. 15 SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A HONEYWELL R8184 SERIES OR EQUIVALENT PRIMARY CONTROL AND A BURNER MOTOR POST-PURGE CONNECT TO L1 OR B1 BLACK ORANGE WHITE THERMOSTAT B O W T T F 115V DRY 24V F HONEYWELL R8184 SERIES OR EQUIVALENT J2 UNIVERSAL CONTROL IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. CALL JUMPER J1 CONNECT TO L2 OR B2 OIL VALVE SUPPLY 115 VAC 50/60 Hz GROUND LEGEND: 115 VAC D/N 9183047-4 10/16/03 XL XN N M MTR BURNER MOTOR IGNITION TRANS VENTER MOTOR IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. Separate the burner motor wire and ignition transformer from the Orange wire of R8184. Connect the Orange of R8184 to #1 on UC1 terminal block. Connect #2 on UC1 terminal block to White on R8184 and L2 or B2. [. . . ] Proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under two years. All receipts should include the date code of the SideShot to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 1. ) Follow troubleshooting guide to determine defective component. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504103 REV C 0204 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag