User manual TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198. We hope that this TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198.


Mode d'emploi TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198
Download
Manual abstract: user guide TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198

Detailed instructions for use are in the User's Guide.

[. . . ] 1 11/98 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com 56826 MODEL SS2G INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important safety information! OWNER INSTRUCTIONS, DO NOT DESTROY NOTE: MAXIMUM FLUE GAS TEMPERATURES MUST NOT EXCEED 650oF. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. DO NOT DESTROY. [. . . ] If wiring the SS2G to an appliance not equipped with the controls shown on the following diagrams, determine which terminals of the gas valve are considered "HOT" and "COMMON" and follow the steps on page 9. When wiring Power Venter to the gas valve wire all thermostats, zones, circulators and limits as would normally be done if venting into a chimney. NAT T PROCEDURES WIRING SS2G WITH SINGLE ZONE THERMOSTAT SEQUENCE OF OPERATION WITH SINGLE ZONE THERMOSTAT: Adjust the furnace thermostat to call for heat. After a slight delay, the furnace burner should fire. The delay is caused by the Power Venter fan proving switch. The delay will be no more than 4 seconds. If you are unable to detect a slight delay, contact Tjernlund Products, Inc. When the fan proving switch closes, the furnace combustion relay is energized. Normal combustion sequence for the furnace begins: induced draft furnace blower starts, its proving switch makes energizing ignition control and/or gas valve. DO NOT OPERATE THE FURNACE WITHOUT THE FAN PROVING SWITCH WIRED INTO THE 24V FURNACE CIRCUIT!NOTE: When Power Venter is interlocked with a thermostat wire all zones, circulators and limits as would normally be done if venting into a chimney. If you are unable to wire the SS2G as outlined in these instructions, call Tjernlund's Customer Service Department toll free at 1-800-255-4208 for assistance. WIRING SS2G WITH THERMOSTAT SS2G WIRED TO 24V GAS VALVE SS2 SEQUENCE OF OPERATION WIRED TO GAS VALVE: As the thermostat/aquastat senses a need for heat, the internal switch of the thermostat/aquastat will close. The Switch closure completes the 24V electrical circuit to the internal controls of the appliance. Before the 24V signal reaches the appliance gas valve, it is interrupted by the Power Venter Relay/Timer and Fan Proving Switch. When the Power Venter Relay/Timer receives the 24V signal, the contact side closes completing the 115V circuit to the Power Venter motor. The air movement generated by the Power Venter closes the Fan Proving Switch and completes the circuit to the appliance gas valve. The appliance gas valve will only receive power when the appliance thermostat/aquastat is calling for heat and the Power Venter is operating. When the appliance thermostat/aquastat is satisfied, 24V will be discontinued to the Relay/Timer and the Power Venter will continue to operate for a nonadjustable post purge period of approximately 45 seconds. 8 9 DRAFT ADJUSTMENT PROCEDURE The SS2G Vent System will properly vent a wide range of BTU/hr. To compensate for different burner capacities, vent connector lengths, types and sizes, it features a draft adjustment located on the back of the venter assembly. Turning this draft adjustment knob clockwise will increase draft and raise the BTU capacity. [. . . ] All receipts should include the date code of the SideShot to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 1. ) Follow troubleshooting guide to determine defective component. If unable to determine faulty component, contact your Tjernlund distributor or Tjernlund Products Technical Customer Service Department at 1-800-255-4208 for troubleshooting assistance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag