User manual TJERNLUND VP-2,3 8504025 REV A 0100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND VP-2,3 8504025 REV A 0100. We hope that this TJERNLUND VP-2,3 8504025 REV A 0100 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND VP-2,3 8504025 REV A 0100.


Mode d'emploi TJERNLUND VP-2,3 8504025 REV A 0100
Download
Manual abstract: user guide TJERNLUND VP-2,3 8504025 REV A 0100

Detailed instructions for use are in the User's Guide.

[. . . ] Patented TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODELS VP-2 For Millivolt Water Heaters up to 60, 000 BTU/hr VP-3 For Millivolt Water Heaters from 60, 000 to 120, 000 BTU/hr THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT OWNERS INSTRUCTIONS DO NOT DESTROY ALWAYS FOLLOW WATER HEATER MANUFACTURER'S INSTRUCTIONS FOR PROPER OPERATION OF HEATER AND RE-LIGHTING OF PILOT WATER HEATER VENT PACKAGE For Natural Gas or LP NOTE: The VP-2 and VP-3 Water Heater Vent Packages use a solenoid valve as part of the safety interlock circuit. The solenoid valve is installed in the gas supply piping to the water heater's thermostat/valve. To save installation time, do not pipe gas to water heater before installing the gas solenoid valve. OPTIONAL PILOT SAVER KIT AVAILABLE The optional Pilot Saver Kit (P/N: 950-2061) allows for Solenoid Valve to be installed in 1/2" burner gas line from water heater gas valve to burner, eliminating pilot outages caused by power interruptions. Rev. [. . . ] If installing the VP-3, 4" vent pipe may be used from the water heater to the Power Venter. If the flue outlet is larger than 4", install a tapered reducer directly after the draft hood of the water heater. NOTE: All reducers and vent pipe are to be supplied by the installer and are available from your local heating wholesaler. The equivalent vent pipe length of elbows and straight pipe must be calculated. The total equivalent length must not exceed 75 feet with no more than 25 equivalent feet in elbows. TAPERED REDUCER 6" CLEARANCE FROM VENTER HOUSING 6 MOUNTING POWER VENTER 1. To facilitate installation and reduce vibration, we have included 2 mounting brackets, 2 rubber isolators and 2 rubber grommets. One of the brackets may be used temporarily as a "third hand" to support the Power Venter while positioning it for permanent installation. NOTE: The Power Venter may be mounted in any position as long as the shaft of the motor remains horizontal. VP-2 MOUNTING VP-3 MOUNTING 2. Connect outlet of Power Venter to inner sleeve of vent hood. Sections of vent pipe are permitted between Power Vent and Vent Hood but all connections after the Power Venter will be under a positive pressure during operation. These connections must be sealed with high temperature silicone sealant or aluminum vent pipe tape supplied by installer. Using the holes as a guide, attach vent pipe to inlet collar using sheet metal screws. Install properly sized vent pipe sections from Power Venter inlet to appliance outlet avoiding elbows wherever possible and using only tapered transitions. Support vent pipe in accordance with vent manufacturer's instructions. ELECTRICAL Route the 25' control cable supplied with the Power Venter back to the water heater controls along the ceiling joists, taking care not to come closer than 6" to the vent pipe or any other potentially hot surface. In most cases, the gas supply line may be used as a routing path from the ceiling to the water heater controls, the supplied nylon straps may be used to secure the cable. NOTE: If the distance between the Power Venter and the heater controls is greater than the length of the cable, splice a section of 3 conductor PVC sheathed, 105 degree C thermostat cable to the supplied cable. Make sure the color coded leads remain consistent. An NEC approved accessible junction box must be used to contain the splice. Splices shall be made mechanically secure and insulated with tape or fixture type splicing connectors may be employed. Strain relief hardware contained within the NEC approved junction box shall be utilized. The Power Venter operates on 110/115 VAC, therefore a grounded outlet must be within reach of the six foot power cord supplied with Power Venter. The flexible power cord supplied with the unit may only be used where local codes permit. [. . . ] 45 second non-adjustable delay) 950-0014 Post Purge Relay/Timer (1 to 10 minute adjustable delay) 950-1067 Linear Limit Spill Switch 950-2064 25' Control Cable 950-2060 Pilot Saver Kit (Optional) 950-2061 Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND VP-2,3 8504025 REV A 0100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND VP-2,3 8504025 REV A 0100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag