User manual TOSHIBA BMS-TP0640ACE INSTALLATION MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA BMS-TP0640ACE. We hope that this TOSHIBA BMS-TP0640ACE user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA BMS-TP0640ACE.


Mode d'emploi TOSHIBA BMS-TP0640ACE
Download
Manual abstract: user guide TOSHIBA BMS-TP0640ACEINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION MANUAL TOUCH SCREEN CONTROLLER for Air Conditioning Control System BMS-TP0640ACE BMS-TP5120ACE BMS-TP0640PWE BMS-TP5120PWE · Thank you very much for purchasing the TOSHIBA Touch Screen Controller. · Please read this manual carefully beforehand for proper installation of the controller. CONTENTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Precautions for Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Outline of Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Accessory parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Description Possible causes Remedy 1 Nothing is displayed on the Touch Screen Controller screen. Touch Screen Controller is not powered on. Backlight turns off automatically due to no touch-screen operation for 10 minutes. Air Conditioning Control System malfunctioned or stopped after local prohibition is set by the system. Operation mode range selection is set by the Air Conditioning Control System. 2 3 4 Remote controller does not work. (Central control in progress) Remote controller does not work. (Operation switchover control in progress) Scheduled operation of air conditioners is disabled. Power on the Touch Screen Controller. Touch the Touch Screen Controller screen. Power off and on the Touch Screen Controller. Check the operation mode range selection setting, and correct it if wrong. Perform setting for scheduled operation. Air Conditioning Control System is not working. Scheduled operation is not set or nonoperation date/special day setting is not updated. (The setting must be updated every year. ) Scheduled operation is not set correctly. Improper connection between power meter and BMS-IFWH3E Charging schedule is not set correctly. Non-operation date/special day setting is not updated. (The setting must be updated every year. ) 5 Air conditioner stops (out of control). Power distribution result is incorrect. 6 Check the scheduled operation setting, and correct it if wrong. Check the charging schedule setting, and correct it if wrong. Fault judgment by Intelligent Server No. Indication Possible causes Remedy 1 An LED other than "RN" LED at the upper left is lighting or flashing after 10 minutes passed from power on of Intelligent Server. No Relay Interface is powered on. Communication with any Relay Interface fails due to improper RS-485 connection or disconnection of connector. Malfunction of Intelligent Server. Check whether every Relay Interface is powered on (shown by LED1 lighting red), and turn on them if powered off. Correct the connection. Power off and on the Intelligent Server. Faults of Relay Interface No. Indication Possible causes Remedy 1 LED2 (green) does not light. (RS-485 communication error) LED3 (orange) does not light. 2 Intelligent Server is not powered on. Improper RS-485 connection or disconnection of connector. [. . . ] During initial communication, 7-segment display section is as follows as follows. Display [A] --- [U1], flashing Display [B] --- [ - - 0] --> [ - - i] flashing After initial communications, [U1] are displayed in 7-segment display section. (If error code is displayed in display section [B], remove the cause reffering to "trouble shooting" of installation or service manual. ) Rotary switch setup SW01 SW02 SW03 1 2 3 1 3 3 1 6 4 1 to 16 4 1 to 3 7-segment display [A] [B] [No. of outdoor units] [Indoor unit address] [ ] 2 Display check 3 System information check (Outdoor side) System capacity No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA BMS-TP0640ACE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA BMS-TP0640ACE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag