User manual TOSHIBA HWS-802XWHM3-E DATA BOOK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA HWS-802XWHM3-E. We hope that this TOSHIBA HWS-802XWHM3-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA HWS-802XWHM3-E.


Mode d'emploi TOSHIBA HWS-802XWHM3-E
Download

You may also download the following manuals related to this product:

   TOSHIBA HWS-802XWHM3-E SERVICE MANUAL (10670 ko)

Manual abstract: user guide TOSHIBA HWS-802XWHM3-EDATA BOOK

Detailed instructions for use are in the User's Guide.

[. . . ] E09-371 Engineering Data Book Air to Water Heat Pump Hydro Unit HWS-802XWHM3-E HWS-802XWHT6-E HWS-1402XWHM3-E HWS-1402XWHT6-E HWS-1402XWHT9-E Outdoor Unit HWS-802H-E HWS-1102H-E HWS-1402H-E Hot Water Cylinder HWS-1501CSHM3-E HWS-2101CSHM3-E HWS-3001CSHM3-E HWS-1501CSHM3-UK HWS-2101CSHM3-UK HWS-3001CSHM3-UK 8 kw 11/14 kw <Hydro unit> <Outdoor unit> <Hot water cylinder> Air to Water Heat Pump Engineering Data Book Contents 1. INTRODUCTION 2 1. INTRODUCTION Engineering Data book to ate Heat Pump System World-leading energy efficiency ­­ COP of 4. 66* Comfortable heating and hot water supply Versatile installation and operation * 11 kW model Welcome Estía to your home!Air-to-water Heat Pump System Introducing Toshiba's super-efficient space heating and hot water supply system for homes and businesses. Estía represents breakthrough thinking in intelligent heat pump and inverter technologies, by efficiently transferring ambient thermal heat from outside air to heat water indoors. [. . . ] Check DIP switch setting on the Hydro Unit board. Check the setting with the function code table. Release air completely according to the procedure. Set hydraulic pressure considering pipe height, and replenish water until manometer shows a value of set hydraulic pressure or more. Widen water path to the hydro unit or adopt a bypass valve. Set hydraulic pressure considering pipe height, and replenish water until manometer shows a value of set hydraulic pressure or more. Check expansion tank capacity compared to total water Insufficient capacity of expansion tank amount. If it is insufficient, install another expansion tank. Expansion tank failure Check the air pressure. Alarm indication E03 Alarm description and generation/reset conditions Regular communication error between hydro unit and remote controller (system controller) If there is no regular communication from the remote controller for three minutes, the hydro unit regards it as no remote controller. If there is no communication from both sides, alarm E03 occurs. Auto-reset: When successful regular communication is made Regular communication error between hydro unit and outdoor unit When serial signal from the outdoor unit cannot be received though normal serial signal is sent to the outdoor unit 1) When serial signal cannot be received continuously for 60 seconds (S code communication) 2) Communication is still not successful for 80 seconds through three retries if serial signal cannot be received for 20 seconds after new communication (f code) starts When the remote controller starts operation, serial transmission starts with the new communication format. Auto-reset: When successful regular communication is made Condensing temperature TC sensor defect If short-circuit or open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed Hydraulic heat exchanger inlet temperature TWI sensor defect If short-circuit or open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed Hydraulic heat exchanger outlet temperature TWO sensor defect If short-circuit or open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed 7 E04 F03 F10 F11 ­ 102 ­ 40-EN 7. HYDRO UNIT INSTALLATION MANUAL Engineering Data Book Alarm indication F14 Alarm description and generation/reset conditions Hot water cylinder temperature TTW sensor defect If short-circuit or open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed Floor inlet temperature TFI sensor defect If short-circuit or open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed Internal heater outlet temperature TWO sensor defect If short-circuit or open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed Floor inlet temperature TFI sensor disconnection or wrong installation (This alarm is reset by stopping operation and is checked again. ) Low-pressure sensor defect If open-circuit state continues for two seconds, an alarm occurs. Auto-reset: When normal value is confirmed Hydraulic heat exchanger EEPROM defect One mismatch is detected if there is no verification ACK after data write to the EEPROM Reset condition: This alarm is inhibited while the unit is not working. (When EEPROM1K is mounted, this alarm cannot be reset. ) Onboard expansion IC defect This alarm is not reset automatically. Group line in an hydro unit This alarm is checked during initial communication immediately after power-on. This alarm occurs immediately after operation start. [. . . ] When the " " mark appears on the remote controller for 4 seconds, the setting is completed. 2 Set STEP. · Select a STEP to be set with the STEP button, and press the SET button to determine the selected STEP. · 1 to 8: Operation program STEP number · C (Copy): Set s the operation mode for a day (0:00 to 23:59) simultaneously. · L (Deletion): Deletes all the current program operation settings (for entire week). 9 ­ 140 ­ 10-EN 9. OWNER'S MANUAL Engineering Data book 4 5 USER MAINTENANCE AIR TO WATER HEAT PUMP OPERATIONS AND PERFORMANCE Periodic maintenance (once a year) is necessary for this product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA HWS-802XWHM3-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA HWS-802XWHM3-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag