User manual TOSHIBA MMY-MAP0802FT DATA BOOK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA MMY-MAP0802FT. We hope that this TOSHIBA MMY-MAP0802FT user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA MMY-MAP0802FT.


Mode d'emploi TOSHIBA MMY-MAP0802FT
Download
Manual abstract: user guide TOSHIBA MMY-MAP0802FTDATA BOOK

Detailed instructions for use are in the User's Guide.

[. . . ] Super-HRM (2 series) Super Heat Recovery Engineering Data Book Multi System 1 Foreword Foreword 1 The engineering data book details all specific data, charts and drawings to enable you to get the best performance from the Toshiba Super Heat Recovery Multi System (2 Series) for the various different applications. The information is aimed to assist you with greater detail of the system and the wider applications that the system will cover. It is recommended the use of the data book is used in accordance with the following as references. Design manual : File No. A04-017 Installation manual : File No. A05-018 1 2 2 1 2 3 4 5 6 7 8 9 Contents Foreword Forward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] IPDU No. 1 MCC-1502 MGSW CN03 T CN02 S CN01 R BLK WHI RED CN08 WHI Reactor CN07 WHI Parts name CM1, CM2 Compressor PMV1, PMV2, PMV3 Pulse motor valve SV2, SV41, SV42, SV51, SV3A, SV3B, SV3C, SV3D, SV3E, SV61, SV11, SV12 2-way valve coil 4WV1 4-way valve coil COMP1, COMP2 Compressor case thermo. sensor HEATER1, HEATER2, ACCUM HEATER Case heater, 230V, 26W FM Fan motor (DC) PS Low pressure sensor PD High pressure sensor 63H1, 63H2 High pressure switch MG-SW Magnet switch OCR Overcurrent relay Comp. The two-dot chain line indicates the wiring on the local site, and the dashed line indicates accessories sold separately and service cables. , , and indicate the terminal blocks and the numbers represents the actual terminal number. * Ensure fixing of the electric parts cover with the supplied two screws. (Otherwise water will enter the box resulting in possible failure). 3. FS Unit (Flow Selector Unit) Model: RBM-Y1122FE, Y1802FE Connection Wiring Diagram Flow Selector Unit RBM-Y1802FE Only Earth Screw Indoor Unit Connection Cable (Control Wiring) SVD SVS SVS SVSS SVDD 1 1 3 3 1 1 3 3 5 5 7 7 9 9 11 COM SVD SVS SVDD SVSS BRW BLU YEL WHI ORN CN01 CN10 (RED) (WHI) Control P. C. Board MCC-1431 CN02 (GRN) 12345 12345 Control P. C. Board for Indoor unit 33 CN67 (BLK) 1 234 5 1 234 5 CN81 (BLK) R(L) S(N) Power Supply Indoor Unit Earth Screw Single Phase 220-240V 50Hz Connection (Control Wiring) Model: RBM-Y2802FE Connection Wiring Diagram Flow Selector Unit Earth Screw Indoor Unit Connection Cable (Control Wiring) SVD SVD SVS SVS SVS SVSS SVDD 1 1 3 3 1 1 3 3 5 5 7 7 9 9 11 COM SVD SVS SVDD SVSS BRW BLU YEL WHI ORN CN01 CN10 (RED) (WHI) Control P. C. Board MCC-1431 CN02 (GRN) 12345 12345 Control P. C. Board for Indoor unit 33 CN67 (BLK) 1 234 5 1 234 5 CN81 (BLK) R(L) S(N) Power Supply Indoor Unit Earth Screw Single Phase 220-240V 50Hz 11 Connection (Control Wiring) 105 106 12 Controls 107 108 LONWORKS Touch screen controller Super Modular Multi Outdoor Unit BMS-LSV2E Intelligent server TCS-Net Interface BMS-IFLSV1E LON Gateway · Monitoring · Remote control · Schedule operation · Error code indication · Alarm list indication · Monthly report · Energy monitoring data etc. Super Digital Inverter Digital Inverter Power peak-cut control board TCB-PCDM2E "1:1model" connection interface TCB-PCNT30TLE 12 Controls External master ON/OFF board TCB-PCDMO2E Energy meter relay Interface BMS-IFWH3E I/F Error output control board TCB-PCIN2E Outline of application Control Local supply Alarm Status output Remote location ON/OFF control board TCB IPCB-4E ON/OFF Command Energy monitoring Batch drive, error output Foreword Power peak-cut control signal Master ON/OFF signal Master ON/OFF signal Control remote controller TCB-SC642TL2 Network adapter TCB-PCNT20E Error/operation output Side remote controller Master remote controller AI-NETWORK Wired remote controller RBC-AMT21E Simple remote controller Wireless remote RBC-AMT31E RBC-AS21E2 controller Weekly timer RBC-EXW21E2 AI-NET Central control devices Weekly timer RBC-EXW21 2 Air-conditioning Management System on site 1 BACnetTM : ANSl/ASHRAE135­1995, A Data CommuniCation Protocol for Bulding Automation and ControI Networks. 2 LoNWoRKS®, Resisterd trademark of Echelon Corporation 109 12 1. Applications for indoor remote controller Basic function System diagram Main remote controller Wireless remote controller Model Wired remote controller RBC-AMT21E RBC-AMT31E Simple remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21U(W)-E2 RBC-AX22CE2 TCB-AX21E2 Individual control 1-1 Air conditioner is individually operated at a distance. Indoor unit Possible up to Max. total length 500m Remote controller Indoor unit Wireless Remote controller Max. 8 indoor units ((( Receiver unit GROUP control 1-2 One remote controller can control a group of up to a maximum. 8 indoor units. Operating on the same setting Indoor unit Indoor unit Indoor unit Indoor unit Wired remote controller RBC-AMT21E RBC-AMT31E Simple remote controller RBC-AS21E2 Remote controller Possible up to Max. total length 500m Wired system Wireless system Indoor unit Indoor unit Two remote control 1-3 Air conditioner is controlled by two remote controllers in two locations. Remote controller Master Remote controller Side Wireless remote controller 1 Master Wireless remote controller 2 Side Wired remote controller RBC-AMT21E RBC-AMT31E Simple remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21U(W)-E2 RBC-AX22CE2 TCB-AX21E2 ((( (( ( 12 Possible up to Max. total length 500m Indoor unit Wired & Wireless combination control (Either one of the two controllers can be set as side control). (( Remote controller Wireless remote controller Weekly timer function · Setting of ON-OFF 3 times par day · Timer operation time is displayed. · Holiday period ( Control by weekly timer 1-4 Weekly schedule operation Indoor unit Wired remote controller RBC-AMT21E RBC-AMT31E + Weekly timer RBC-EXW21E2 Remote controller Weekly timer 110 2. Application controls for central remote controller Basic function Header unit System diagram Super MMS Outdoor unit Line-3 Indoor unit U5, U6 Model U3, U4 Zone 4 U1, U2 Header unit Indoor remote controller Outdoor unit U5, U6 Line-2 Super MMS Indoor unit U3, U4 Zone 3 U1, U2 Zone 2 Header unit Indoor remote controller Outdoor unit Line-1 Super HRM Indoor unit U3, U4 Central remote controller TCB-SC642TLE2 Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E Simple remote controller RBC-AS21E2 Zone 1 U1, U2 FS unit 2-1 Central management controller for 64 units Indoor remote controller Power Central supply remote controller Single phase 220/230/240V Function of central remote controller Individual control for up to 64 indoor units. (Up to 16 indoor units for each zone. ) Up to 16 outdoor header units are connectable. 4 specific central control settings to restrict individual operation by remote controller are selectable. Different settings for one of 1 to 4 zones. Usable with other central control devices (Up to 10 central control devices in one control circuit) Two selectable control modes Central controller mode/Remote controller mode Setting of simultaneous ON/OFF 3 times per day when a controller is combined with using a weekly timer. 12 U3, U4 Outdoor unit Indoor unit U1, U2 2-2 Central remote controller + Weekly timer Weekly operation schedule can be set by connecting a weekly timer to the central remote controller Central remote controller TCB-SC642TLE2 + Weekly timer RBC-EXW21E2 Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E or Simple remote controller RBC-AS21E2 FS unit Indoor remote controller Single phase 220/230/240V Power supply Weekly timer Central remote controller 111 Basic function U3, U4 System diagram Model Outdoor unit U1, U2 Power supply Single phase 220/230/240V Indoor unit FS unit Central remote controller Even when grouping operation is performed by connecting multiple indoor units to 1 line, the indoor remote controller is required. [. . . ] Sound Characteristics (NC Curve) MMD-AP0071SPH/SH , MMD-AP0091SPH/SH Measuring location Rear air intake Air outlet Center 1. 5m Microphone 2m 1m Duct Duct Air inlet External static pressure 10Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 20Pa M L 24 Fan tap Sound pressure level (dB(A)) 70 H 28 H 29 M 27 L 25 26 60 60 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 50 NC-50 50 NC-50 40 NC-40 40 NC-40 30 30 NC-30 NC-30 20 Approximate threshold of hearing for continuous noise H M L NC-20 H M 20 L Approximate threshold of hearing for continuous noise NC-20 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 50Pa M L 26 Fan tap Sound pressure level (dB(A)) 70 H 30 H 32 M 29 L 27 28 60 60 Octave band sound pressure level (dB) 50 Octave band sound pressure level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 30 H 20 Approximate threshold of hearing for continuous noise NC-30 30 H M NC-30 M L 20 L NC-20 Approximate threshold of hearing for continuous noise NC-20 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 18 A-44 7. Sound Characteristics (NC Curve) MMD-AP0121SPH/SH Measuring location Air outlet 2m 1m Duct Duct Air inlet Center 1. 5m Microphone Rear air intake External static pressure 10Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 20Pa M L 25 Fan tap Sound pressure level (dB(A)) 70 H 29 H 30 M 28 L 26 27 60 60 Octave band sound pressure level (dB) 50 Octave band sound pressure level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 30 H M NC-30 30 H M L NC-30 20 Approximate threshold of hearing for continuous noise L NC-20 20 Approximate threshold of hearing for continuous noise NC-20 10 63 125 250 500 1000 2000 4000 8000 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 50Pa M L 27 Fan tap Sound pressure level (dB(A)) 70 H 31 H 32 M 30 L 28 29 60 60 Octave band sound pressure level (dB) 50 Octave band sound pressure level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 30 H M L NC-30 H 30 M L NC-30 20 20 NC-20 Approximate threshold of hearing for continuous noise NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) A-45 19 7. Sound Characteristics (NC Curve) MMD-AP0151SPH/SH Measuring location Air outlet 2m 1m Duct Duct Air inlet Center 1. 5m Microphone Rear air intake External static pressure 10Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 20Pa M L 28 Fan tap Sound pressure level (dB(A)) 70 H 32 H 33 M 31 L 29 30 60 60 Octave band sound pressure level (dB) 50 Octave band sound pressure level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 30 H M NC-30 30 H M NC-30 20 L NC-20 Approximate threshold of hearing for continuous noise 20 L NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 50Pa M L 30 Fan tap Sound pressure level (dB(A)) 70 H 34 H 35 M 33 L 31 32 60 60 50 Octave band sound pressure level (dB) Octave band sound pressur level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 30 H M L NC-30 30 H M L NC-30 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) 20 A-46 7. Sound Characteristics (NC Curve) MMD-AP0181SPH/SH Measuring location Air outlet 2m 1m Duct Duct Air inlet Center 1. 5m Microphone Rear air intake External static pressure 10Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 20Pa M L 29 Fan tap Sound pressure level (dB(A)) 70 H 33 H 34 M 32 L 30 31 60 60 50 Octave band sound pressure level (dB) Octave band sound pressure level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 30 H M L H 30 NC-30 M NC-30 L 20 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) 70 External static pressure 50Pa M L 31 Fan tap Sound pressure level (dB(A)) 70 H 35 H 36 M 34 L 32 33 60 60 Octave band sound pressure level (dB) 50 Octave band sound pressure level (dB) NC-50 50 NC-50 40 NC-40 40 NC-40 H 30 H 30 NC-30 M L 20 M L 20 NC-30 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 10 63 125 250 500 1000 2000 NC-20 Approximate threshold of hearing for continuous noise 4000 8000 Octave band center fequency (Hz) Octave band center frequency (Hz) A-47 21 7. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA MMY-MAP0802FT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA MMY-MAP0802FT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag