User manual TOSHIBA RAS-107SKV-E SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-107SKV-E. We hope that this TOSHIBA RAS-107SKV-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-107SKV-E.


Mode d'emploi TOSHIBA RAS-107SKV-E
Download
Manual abstract: user guide TOSHIBA RAS-107SKV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-08020 SERVICE MANUAL SPLIT TYPE Indoor Unit <High Wall, Heat Pump Type> Outdoor Unit <Heat Pump Type> RAS-107SKV-E RAS-107SAV-E R410A March, 2008 FILE NO. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The indoor unit shall be installed so that the top of the indoor unit is positioned at least 2m in height. Also, avoid putting anything on the top of the indoor unit. 10-3-2. Drilling a Hole and Mounting Installation Plate Drilling a hole When install the refrigerant pipes from the rear. Pipe hole 65 mm CAUTION Direct sunlight on the indoor unit wireless receiver should be avoided. The microprocessor in the indoor unit should not be too close to r-f sources. (For details, see the owner's manual. ) Fig. 10-3-2 100 mm Remote controller Should be placed where there are no obstacles, such as curtains, that may block the signal. Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. Keep the remote controller at least 1 m away from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) The location of the remote controller should be determined as shown below. 1. After determining the pipe hole position on the installation plate ( ) drill the pipe hole (65 mm) at a slight downward slant to the outdoor side. NOTE : When drilling into a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. Mounting the installation plate Anchor bolt holes Hook 62 82. 5 Indoor unit (Side view) (Top view) Indoor unit 170 85 Reception range Remote controller Reception range Remote controller Pipe hole Hook Indoor unit Hook Thread Weight Pipe hole Installation plate 1 7 Mounting screw Fig. 10-3-3 49 2 m or more from floor FILE NO. SVM-08020 When the installation plate is directly mounted on the wall 1. Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out. To mount the installation plate on a concrete wall use anchor bolts. Drill the anchor bolt holes as illustrated in the above figure. Install the installation plate horizontally and level. 10-3-3. The supply voltage must be the same as the rated voltage of the air conditioner. Prepare a power source for the exclusive use of the air conditioner. NOTE : Wire type : More than 1. 5 mm2 H07RN-F or 60245IEC66. CAUTION When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage. CAUTION This appliance can be connected to a main circuit breaker in either of the following two ways. Connection to fixed wiring: A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring. An approved circuit breaker or switch must be used. Connection with power supply plug: Attach power supply plug with power cord and plug it into wall outlet. An approved power supply cord and plug must be used. Anchor bolt Projection 15mm or less Fig. [. . . ] 2) Cut the protective tube after pulling out it (200 mm). 3) Move the protective tube toward the thermal sensor side and tear the tip of lead wire in two then strip the covering part. 4) Pass the stripped part through the thermal constringent tube. 5) Cut the old sensor 100 mm length on the connector side, and recycle that connector. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-107SKV-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-107SKV-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag