User manual TOSHIBA RAS-10JKVP-E PSD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-10JKVP-E. We hope that this TOSHIBA RAS-10JKVP-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-10JKVP-E.


Mode d'emploi TOSHIBA RAS-10JKVP-E
Download
Manual abstract: user guide TOSHIBA RAS-10JKVP-EPSD

Detailed instructions for use are in the User's Guide.

[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate. Hook here a Installation plate Hook Press (unhook) · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places. Push Push Drainage 1. Run the drain hose at a downward sloped angle. NOTE · Hole should be made at a slight downward slant on the outdoor side. Do not route the drain hose upwards. Do not form the drain hose into a waved shape. 50 mm or more Do not put the drain hose end into water. Do not put the drain hose end in a drainage ditch. 2. 3. Put water in the drain pan and make sure that the water is being drained outside. When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe. Shield pipe Drain hose Inside the room Extension drain hose CAUTION Install the drain pipe for proper drainage. Improper drainage can result in water dripping inside the room. This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan. Therefore, do not locate the power cord and other parts at a height above the drain guide. Wall Drain guide Space for pipes ­ 56 ­ 10-4. Installation of Outdoor Unit Installation Location A place which provides enough space around the outdoor unit as shown in the diagram. If a centralized drain is required when installing the unit on a balcony or wall, follow the steps below to drain off the water. Proceed with water-proofing by installing the water-proof rubber caps j in the 2 elongated holes on the base plate of the outdoor unit. [How to install the water-proof rubber caps] 1) Place four fingers into each cap, and insert the caps into the water drain holes by pushing them into place from the underside of the base plate. 2) Press down on the outer circumferences of the caps to ensure that they have been inserted tightly. (Water leaks may result if the caps have not been inserted properly, if their outer circumferences lift up or the caps catch on or wedge against something. ) 2. Install the drain nipple i and a commercially available drain hose (with 16 mm inside diameter), and drain off the water. (For the position where the drain nipple i is installed, refer to the installation diagram of the indoor and outdoor units. ) · Check that the outdoor unit is horizontal, and route the drain hose at a downward sloped angle while ensuring that it is connected tautly. j Water-proof rubber caps (supplied with the outdoor unit) Base plate i Drain nipple Base plate i Drain nipple Commercially available drain hose Do not use ordinary garden hose, which can flatten and prevent water from draining. ­ 57 ­ Refrigerant Piping Connection Flaring 1. Cut the pipe with a pipe cutter. Obliquity Roughness Warp 2. Insert a flare nut into the pipe, and flare the pipe. · Projection margin in flaring: A (Unit: mm) Rigid (Clutch type) Outer diameter of copper pipe 6. 35 9. 52 12. 7 R410A tool used 0 to 0. 5 0 to 0. 5 0 to 0. 5 Imperial (Wing nut type) Outer diameter of copper pipe 6. 35 9. 52 12. 7 R410A 1. 5 to 2. 0 1. 5 to 2. 0 2. 0 to 2. 5 Conventional tool used 1. 0 to 1. 5 1. 0 to 1. 5 1. 0 to 1. 5 Die Pipe 3. Flaring size : B (Unit : mm) Outer diameter of copper pipe 6. 35 9. 52 12. 7 R410A 9. 1 13. 2 16. 6 B +0 ­0. 4 R22 9. 0 13. 0 16. 2 · In case of flaring for R410A with the conventional flare tool, pull it out approx. 0. 5 mm more than that of R22 to adjust to the specified flare size. The copper pipe gauge is useful for adjusting projection margin size. Tighten the connection Align the centers of the connecting pipes and tighten the flare nut as much as possible with your fingers. [. . . ] When there is the heating part near the electric parts box, a fire may generate. Be sure to set the heating part on the outdoor unit base plate at the fan room side or near it. (within 20cm from the outdoor unit base plate) * Be careful that the cord heater does not hit the fan. Fix the cord heater without any loosening or sag. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-10JKVP-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-10JKVP-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag