User manual TOSHIBA RAS-13SKH-E SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-13SKH-E. We hope that this TOSHIBA RAS-13SKH-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-13SKH-E.


Mode d'emploi TOSHIBA RAS-13SKH-E
Download
Manual abstract: user guide TOSHIBA RAS-13SKH-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] T O S H IB A S E R V IC E M A N U A L F IL E N O . A 0 0 -9 6 2 7 A IR -C O N D IT IO N E R R A S -1 3 S K H -E R A S -1 3 S K H X S P L IT W A L L T Y P E R A S -1 3 S A H -E R A S -1 3 S A H X P R IN T E D IN J A P A N , D e c . , 1 9 9 6 ToM o CONTENTS 1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Wire type:More than H05 RN-F Fig. 8-4-10 <How to install the front cabinet on the indoor unit> Install the front cabinet through the opposite order of "How to remove the front cabinet". When the panel is removed and mounted again, take the following actions: After fastening the two screws, one each at the left and right of the air outlet, be sure to push the upper center 1 right end 2 , left end 3 and the lower center 4 of the air outlet, and confirm that no gap is left between the front cabinet and the rear plate. · If cooling (dry) operation is made without pushing the air outlet, dew can be deposited on the front cabinet surface. In addition a gap between the front cabinet and the rear plate will become wider, spoiling the appearance. Push Earth line CAUTION · Be sure to refer the wiring system diagram labeled inside the front panel. · Check local electrical codes and also any specific wiring instructions or limitation. Terminal block Connecting cable Cord Terminal clamp cover Screw Push 1 Push 2 3 abo ut 1 5cm Screw Screw Connecting cable 4 Push Fig. Piping and Drain Hose Installation <In case of rightward piping> · After scribing slits of the front panel and the rear panel by a knife or a marking-off pin, cut them by a pair of nippers or the like. Slit (front panel) To connect pipe after installation of unit (figure) (To the forefront of flare) 196mm 96mm Side of liquid flow Side of gas flow Outward form of indoor unit 43mm R 30mm (Use polisin or the like for bending pipe. ) 80 ° Use the handle of screwdriver, etc. Slit (rear panel) Fig. 8-4-14 NOTE : If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to auxiliary pipes and wrap the facing tape around them. Fig. 8-4-12 <In case of downward piping> · After scribing the slit of the front panel and slit in the lower part of the rear panel by a knife or a marking-off pin, cut them by a pair of nippers or the like. CAUTION · Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape. Indoor unit Auxiliary pipes Connecting cable Slit (front panel) Slit (rear panel) Fig. 8-4-13 <Left-hand connection with piping> Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use spring bender so as not to crush the pipe. Bend the connection pipe within a radius of 30 mm. Installation plate · Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit. · Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc. · Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) · When bending a pipe, carefully do it not to crush it. ­ 30 ­ 8-4-5. Indoor Unit Installation (1) Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. (2) Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate. (3) While pressing the indoor unit onto the wall by the lower part, hook it up on the installation plate by the lower part. Pull the indoor unit toward you by the lower part to confirm that it is firmly hooked up on the installation plate. (1) 8-4-6. [. . . ] (7- ST1T ø4 x 10 with nylon washer) · Pull the front lower portion toward you, and remove it pulling out upward. Remarks Capacitor for compressor 1) Perform the process above. 2) Remove the fixing screw securing the capacitor band. (1- ST2T ø4 x 8 ) 3) Remove the cable connected to the terminal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-13SKH-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-13SKH-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag