User manual TOSHIBA RAS-16NKV-E SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-16NKV-E. We hope that this TOSHIBA RAS-16NKV-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-16NKV-E.


Mode d'emploi TOSHIBA RAS-16NKV-E
Download
Manual abstract: user guide TOSHIBA RAS-16NKV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-05027 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13NKV-E / RAS-13NAV-E RAS-13NKV-A / RAS-13NAV-A RAS-16NKV-E / RAS-16NAV-E RAS-16NKV-A / RAS-16NAV-A May, 2005 FILE NO. SPECIFICATIONS 1-1 1-2 1-3 Specifications Operation Characteristic Curve Capacity Variation Ratio According to Temperature Safety During Installation/Servicing Refrigerant Piping Installation Tools Recharging of Refrigerant Brazing of Pipes Indoor Unit Outdoor Unit Indoor Unit (For 13NKV) Indoor Unit (For 16NKV) Outdoor Unit Indoor Unit (For 13NKV) Indoor Unit (For 16NKV) Outdoor Unit (For 13NAV) Outdoor Unit (For 16NAV) Refrigerant Cycle Diagram Operation Data Indoor Unit Outdoor Unit (Inverter Assembly) Outlined of Air Conditioner Control Description of Operation Circuit Temporary Operation Auto Restart Function Filter Check Lamp Remote Control and its Functions Safety Cautions Indoor Unit Outdoor Unit 2. REFRIGERANT R410A 2-1 2-2 2-3 2-4. 2-5. 3. CONSTRUCTION VIEWS 3-1 3-2 4. WIRING DIAGRAM 4-1 4-2 4-3 5. SPECIFICATION OF ELECTRICAL PARTS 5-1 5-2 5-3 5-4 6. REFRIGERANT CYCLE DIAGRAM 6-1 6-2 7. CONTROL BLOCK DIAGRAM 7-1 7-2 8. OPERATION DESCRIPTION 8-1 8-2 8-3 8-4 8-5 8-6 9. INSTALLATION PROCEDURE 9-1 9-2 9-3 - 1- FILE NO. HOW TO DIAGNOSE THE TROUBLE 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-9 First Confirmation Primary Judgment Judgment by Flashing LED of Indoor Unit Self-Diagnosis by Remote Control (Check Code) Judgment of Trouble by Every Symptom Check Code 1C (Miswiring in indoor/outdoor units) and 1E How to Diagnose Trouble in Outdoor Unit How to Check Simply the Main Parts How to Simply Judge Whether Outdoor Fan Motor is Good or Bad 11. [. . . ] Take out the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm from the front. Insert the connecting cable fully into the terminal block and secure it tightly with screws. Tightening torque : 1. 2 Nm (0. 12 kgfm) 7. Secure the connecting cable with the cord clamp. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor unit. Piping and drain hose installation <Piping and Drain Hose Forming> * Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) Rear right Left Bottom right Right Fig. Die-cutting Front panel slit Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers. Changing drain hose For left connection, bottom-leftward connection and rear-leftward connection's piping, it is necessary to change the drain hose and drain cap. <How to remove the Drains Cap> Clip drain cap by needle-nose pliers, and pull out. CAUTION Be sure to refer to the wiring system diagram labeled inside the front panel. Check local electrical cords and also any specific wiring instructions or limitations. Fig. 9-2-9 <How to install the Drain Hose> Firmly insert drain hose connecting part until hitting on a heat insulator. Heat insulator NOTE : Use stranded wire only. 9-2-7 Stripping length of connecting cable Fig. 9-2-10 50 Die-cutting Front panel slit Bottom left Drain hose Changing drain hose Rear left Piping preparation FILE NO. SVM-05027 <How to fix the Drains Cap> <Left-hand connection with piping> 1) Insert hexagonal wrench (4 mm) in a center head. Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use a spring bender so 4 mm as not to crush the pipe. Bend the connection pipe within a radius of 30 mm (6. 35) 40 mm (9. 52). Fig. 9-2-11 2) Firmly insert drains cap. To connect the pipe after installation of the unit (figure) (To the forefront of flare) 270 mm No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Application causes deterioration and drain leakage of the plug. 43 mm Liquid side Gas side 170 mm Outward form of indoor unit R 30 mm or less (6. 35) R 40 mm or less (9. 52) (Use polisin (polyethylene core) or the like for bending pipe. ) Insert a hexagon wrench (4 mm) Fig. 9-2-12 80 CAUTION Firmly insert the drain hose and drain cap; otherwise, water may leak. Use the handle of screwdriver, etc. Fig. 9-2-15 NOTE: If the pipe is bent incorrectly, the indoor unit may <In case of right or left piping> After scribing slits of the front panel with a knife or a unstably be set on the wall. [. . . ] Attachment 1) Insert claw of the fan guard in the hole of the front cabinet. Push the hooking claws (10 positions) by hands and fix the claws. Check that all the hooking claws are fixed to the specified positions. Minus screwdriver Hooking claw 88 FILE NO. SVM-05027 No. " Part name Replacement of temperature sensor for servicing only Procedures 1) Cut the sensor 100 mm longer than old one. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-16NKV-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-16NKV-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag