User manual TOSHIBA RAS-24GFP-ES2 SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-24GFP-ES2. We hope that this TOSHIBA RAS-24GFP-ES2 user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-24GFP-ES2.


Mode d'emploi TOSHIBA RAS-24GFP-ES2
Download
Manual abstract: user guide TOSHIBA RAS-24GFP-ES2SERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-06021 SERVICE MANUAL AIR-CONDITIONER UNDER CEILING / CONSOLE TYPE RAS-18GFHP-ES2 / RAS-18GAH-ES2 RAS-18GFP-ES2 / RAS-18GA-ES2 RAS-24GFHP-ES2 / RAS-24GAH-ES2 RAS-24GFP-ES2 / RAS-24GA-ES2 18 Class 24 Class June, 2006 FILE NO. CONSTRUCTION VIEWS 2-1 Indoor Unit 2-2 Outdoor Unit (24 Class) 2-3 Outdoor Unit (18 Class) 3. WIRING DIAGRAM 3-1 3-2 3-3 3-4 4-1 4-2 4-3 4-4 4-5 4-6 5-1 5-2 5-3 5-4 RAS-18GFHP-ES2 / RAS-18GAH-ES2 RAS-24GFHP-ES2 / RAS-24GAH-ES2 RAS-18GFP-ES2 / RAS-18GA-ES2 RAS-24GFP-ES2 / RAS-24GA-ES2 Indoor Unit (RAS-24GFHP-ES2, RAS-18GFHP-ES2) Outdoor Unit (RAS-24GAH-ES2) Outdoor Unit (RAS-18GAH-ES2) Indoor Unit (RAS-24GFP-ES2, RAS-18GFP-ES2) Outdoor Unit (RAS-24GA-ES2) Outdoor Unit (RAS-18GA-ES2) RAS-18GFHP-ES2 / RAS-18GAH-ES2 RAS-18GFP-ES2 / RAS-18GA-ES2 RAS-24GFHP-ES2 / RAS-24GAH-ES2 RAS-24GFP-ES2 / RAS-24GA-ES2 4. CONTROL BLOCK DIAGRAM 6-1 RAS-18GFHP-ES2, RAS-24GFHP-ES2 6-2 RAS-18GFP-ES2, RAS-24GFP-ES2 7. [. . . ] It is therefore necessary to tighten firmly flare pipe connecting sections (which connect the indoor and outdoor units) up to the specified tightening torque. Incorrect connections may not only cause a gas leakage, but also damage the refrigerant cycle. Flare at outdoor unit side Fig. 8-5-4 Half union Externally threaded side Flare nut Internally threaded side Compound pressure gauge Pressure gauge Manifold valve Handle Hi (Keep full closed) Charge hose (For R410A only) Vacuum pump adapter for counter-flow prevention (For R410A only) Vacuum pump ­101 kPa (­76 cmHg) Handle Lo Use a wrench to secure. Use a torque wrench to tighten. Charge hose (For R410A only) Connecting pipe Fig. 8-5-5 CAUTION · KEEP IMPORTANT 4 POINTS FOR PIPING WORK (1) Take away dust and moisture (Inside of the connecting pipes). (2) Tight connection (between pipes and unit). (3) Evacuate the air in the connecting pipes using VACUUM PUMP. ­ 45 ­ Packed valve at liquid side Packed valve at gas side Service port (Valve core (Setting pin)) Fig. SVM-06021 TO CHARGE REFRIGERANT RAS-18GFHP-ES2 / 18GAH-ES2 RAS-24GFHP-ES2 / 24GAH-ES2 RAS-18GFP-ES2 / 18GA-ES2 RAS-24GFP-ES2 / 24GA-ES2 <Stripping length of connecting cable> Terminal block No need to charge refrigerant Need to charge refrigerant L N 1 2 3 15 m or less Over 15 m up to 20 m (20g/m) 15 m or less Over 15 m up to 25 m (20g/m) Terminal screw Cord clamp Earth line Screw Cord clamp <Packed valve handling precautions> · Open the valve stem all the way out; but do not try to open it beyond the stopper. · Securely tighten the valve stem cap with torque in the following table: Pipe side Gas side (12. 70 mm) Liquid side (6. 35 mm) Service port Tightening torque 50 to 62 N·m (5. 0 to 6. 2 kgf·m) 16 to 18 N·m (1. 6 to 1. 8 kgf·m) 9 to 10 N·m (0. 9 to 1. 0 kgf·m) A 4 mm Same as Gas side Power supply cord Connecting cable Fig. 8-5-8 LN 10 12 3 10 10 70 60 10 60 70 Earth line Power supply cord Connecting cable Fig. 8-5-9 RAS-18GFHP-ES2 / 18GAH-ES2 RAS-18GFP-ES2 / 18GA-ES2 RAS-24GFHP-ES2 / 24GAH-ES2 RAS-24GFP-ES2 / 24GA-ES2 · Hexagonal wrench : A (Unit : mm) Hexagonal wrench is required. A Power source Maximum running current Plug socket & fuse rating Power cord 50 Hz, 220 ­ 240 V Single phase 16A 20A 4 mm2 (H07RN-F or 245 IEC 66) or 3. 5 mm2 (AWG-12) 18A Fig. 8-5-7 CAUTION · Wrong wiring connection may cause some electrical parts burn out. · Be sure to comply with local codes on running the wire from indoor unit to outdoor unit (size of wire and wiring method etc). · Every wire must be connected firmly. NOTE: Connecting cable · Wire type : More than 1. 5 mm2 (H07RN-F or 245 IEC66) or 1. 3 mm2 (AWG-16) 8-5-4. Remove the electric parts cover from the outdoor unit. Connect the connecting cable to the terminal as identified with their respective matched numbers on the terminal block of indoor and outdoor unit. When connecting the connecting cable to the outdoor unit terminal, make a loop as shown in the installation diagram of indoor and outdoor unit, to prevent water coming in the outdoor unit. Insulate the unused cords (conductors) from any water coming in the outdoor unit. Proceed them so that they do not touch any electrical or metal parts. ­ 46 ­ FILE NO. How to Set Remote Control Selector Switch When two indoor units ae installed in seperated rooms, there is no need to change the selector switch. <Remote control selector switch> · When two indoor units are installed in the same room or the adjacent two rooms, they may be controlled simultaneously with a single remote control. [. . . ] 43T09379 43T00357 43T00431 43T00432 43T01306 43T79312 43T80302 43T00433 43T00434 43T20303 43T20304 43T20317 43T19309 43T21369 43T72309 43T70311 43T19323 43T09378 43T44318 Description AIR-GRILLE PANEL ARM ASSY FRONT PANEL ASSY (FOR RAS-18, 24GFP-ES2) FRONT PANEL ASSY (FOR RAS-18, 24GFHP-ES2) MARK DRAIN BAND AIR FILTER CAP SCREW C CAP SCREW LR FAN COVER MOTOR BAND ASSY FAN ASSY (MULTIBLADE FAN) SCREW SET (D-T) FAN MOTOR DRAIN PAN ASSY DRAIN HOSE ASSY STEPPING MOTOR HORIZONTAL LOUVER FLOCK REFRIGERATION ASSY (FOR RAS-24GFHP-ES2, GFP-ES2) Location No. 218 219 220 221 222 223 224 225 226 227 228 229 230 231 231 233 234 235 Part No. 43T44319 43T03344 43T09314 43T49303 43T19324 43T19325 43T19328 43T19326 43T19327 43T82308 43T60314 43T62303 43T83003 43T69421 43T69422 43T49326 43T80003 43T00365 Description REFRIGERATION ASSY (FOR RAS-18GFHP-ES2, GFP-ES2) BACK BODY ASSY VERTICAL LOUVER PIPE HOLDER COVER BODY L COVER BODY R COVER BODY LD BUSH BODY R BUSH BODY D INSTALLATION PLATE TERMINAL COVER CONNECTOR COVER HOLDER; REMOTE CONTROLLER WIRELESS-REMOCO (FOR RAS-18, 24GFHP-ES2) WIRELESS-REMOCO (FOR RAS-18, 24GFP-ES2) FLEXIBLE PIPE ASSY FILTER; FRAME ASM-GRILLE-STOPPER ­ 77 ­ FILE NO. Outdoor Unit (RAS-24GAH-ES2) Location No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-24GFP-ES2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-24GFP-ES2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag