User manual TOSHIBA RAV-160UH-P SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-160UH-P. We hope that this TOSHIBA RAV-160UH-P user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAV-160UH-P.


Mode d'emploi TOSHIBA RAV-160UH-P
Download
Manual abstract: user guide TOSHIBA RAV-160UH-PSERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1. Outdoor unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1. 3-2 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-3 Dimension. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-5 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Sound characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Capacity variation ratio according to temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 3 RAV-SM802BT-E (Round duct) 140 Standard air volume 780m3/h Standard air volume 1140m3/h 120 120 Hig 100 h st atic High s pres sure 2H tap Static pressure (Pa) 100 tatic p ressu U Static pressure (Pa) 80 le l sab t imi re 2H Hig hs U le l sab t imi tap tati cp High res static sur e1 80 press ure 1 60 Air volume limit (Max. ) H ta H tap Air volume limit (Min. ) p Sta 60 tap 40 Low 40 Air volume limit (Min. ) p sta tic p Low s tatic p res sur ressure eH H tap 20 tap Sta 20 nda Standa rd L ta p rd L tap 780 3 0 500 700 900 0 800 1000 1140 3 1200 Air volume m /h Air volume m /h Fig. 2 RAV-SM562BT-E (Square duct) 140 Fig. 4 RAV-SM802BT-E (Square duct) 140 Standard air volume 780m3/h 120 108 100 Us le ab li t mi High stat ic p ress ure 2H 120 High sta it lim tic pres sure 2H tap 100 tap Hig hs tati Us abl e cp res High s sur tatic pre e1 ssure 1 Static pressure (Pa) 80 Static pressure (Pa) H ta H tap p Air volume limit (Max. ) 80 Air volume limit (Min. ) rd H Air volume limit (Min. ) 60 tap Standa 60 rd H tap Low sta tic p Low s 40 res tatic p sur ressure eH tap 40 H tap Stand Sta ard L nda tap 20 rd L tap 20 0 500 700 780 3 900 0 800 1000 1140 3 1200 1300 Air volume m /h Air volume m /h 2-24 Air volume limit (Max. ) Sta nda Air volume limit (Max. ) 1300 nda rd H Standa rd H ta Fig. 7 RAV-SM1402BT-E (Round duct) 140 Standard air volume 1620m3/h 140 Standard air volume 1980m3/h 120 120 High 100 stati c pr Us Static pressure (Pa) 80 el abl t imi essu re 2 H ta p 100 c pr essu Static pressure (Pa) High stati U l sab e li mit Hig hs tati cp res sur e2 H ta p Hig hs tati cp res sur e1 H ta p Sta nda rd H re 1 H ta 80 p Air volume limit (Max. ) Air volume limit (Min. ) 60 60 Sta Low nda rd H tap tap 40 stat 40 ic p ress ure H ta 20 Stan p Low sta tic p res sur eH Sta nda rd L tap tap dard 20 L ta p 0 1200 0 1200 1620 2000 3 1800 1980 3 2200 Air volume limit (Max. ) 2400 Air volume limit (Min. ) Air volume m /h Air volume m /h Fig. 8 RAV-SM1402BT-E (Square duct) 140 Standard air volume 1620m3/h High 140 Standard air volume 1980m3/h static 120 press U 100 le l sab t imi ure 2 H tap 120 High static High static 100 U le l sab t imi pres sure 2H t ap press High ure 1 Static pressure (Pa) 80 Static pressure (Pa) H tap Air volume limit (Max. ) static pres sure 1H t ap Air volume limit (Max. ) 2400 80 Air volume limit (Min. ) Stand Air volume limit (Min. ) 60 ard H Stan tap dard 60 H ta p 40 Low static press ure H tap Stan dard L tap Low stat ic pr 40 essu re H tap Stan dard L tap 20 20 0 1200 1620 2000 3 0 1200 1800 1980 3 2200 Air volume m /h Air volume m /h 2-25 2-2-8. Sound Characteristics RAV-SM562BT-E RAV-SM802BT-E Fan tap Sound pressure level (dB(A)) H 40 M 37 L 33 Fan tap Sound pressure level (dB(A)) H 40 M 37 L 34 Octave band sound pressure level (dB) (Standard pressure 0. 0002 bar) 60 Octave band sound pressure level (dB) (Standard pressure 0. 0002 bar) 60 50 NC-50 NC-50 50 NC-40 40 NC-40 40 NC-30 30 NC-30 30 20 EH H M L NC-20 Audifility limits of continous white level 20 EH H M L NC-20 Audifility limits of continous white level 10 20~75 75~150 150~300 300~600 600~1200 1200~2400 2400~4800 4800~9600 10 20~75 75~150 150~300 300~600 600~1200 1200~2400 2400~4800 4800~9600 Octave band frequency (Hz) Octave band frequency (Hz) RAV-SM1102BT-E Fan tap Sound pressure level (dB(A)) H 42 M 39 L 36 RAV-SM1402BT-E Fan tap Sound pressure level (dB(A)) H 44 M 41 L 38 Octave band sound pressure level (dB) (Standard pressure 0. 0002 bar) 60 Octave band sound pressure level (dB) (Standard pressure 0. 0002 bar) 60 NC-50 50 NC-50 50 NC-40 40 NC-40 40 NC-30 30 NC-30 30 20 EH H M L NC-20 Audifility limits of continous white level 20 EH H M L NC-20 Audifility limits of continous white level 10 20~75 75~150 150~300 300~600 600~1200 1200~2400 2400~4800 4800~9600 10 20~75 75~150 150~300 300~600 600~1200 1200~2400 2400~4800 4800~9600 Octave band frequency (Hz) Octave band frequency (Hz) 2-26 2-3. Single system Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Twin system specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimension. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Refrigerant cycle diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O B / Modulating (PMV) (SKV-18D26) Ps TS sensor TD sensor Strainer 4-way valve (STF-0213Z) Muffler O 25 / O 25 / TE sensor Heat exchanger O 8 / 1 row 30 stages FP1. 3 flat fin Accumulator (1500cc) x L210 x L160 Capillary O 3x O2x / / L530 Rotary compressor (DA220A2F-20L) R410A 2. 1 kg Cooling Heating Pressure (MPa) Pd Standard Cooling Overload Low load Standard Heating Overload Low load 2. 72 3. 57 1. 89 2. 58 3. 49 2. 30 Ps 0. 93 1. 10 0. 74 0. 68 1. 22 0. 25 Discharge (TD) 74 80 34 72 79 91 Pipe surface temperature (oC) Suction (TS) 12 21 7 4 19 - 17 Indoor heat exchanger (TC) 11 17 2 41 55 37 Indoor/Outdoor temp. Compressor conditions revolutions per Indoor Outdoor heat second (rps) (DB/WB) (oC) fan exchanger Indoor Outdoor (TE) * 40 52 12 2 16 ­19 55 47 24 62 28 90 HIGH HIGH LOW HIGH LOW HIGH 27/19 32/24 18/15. 5 20/30/15/35/43/-5/7/6 24/18 -15/(70%) * 4 poles are provided to this compressor. The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor. 2-33 RAV-SM1102CT-E / RAV-SP1102AT-E Indoor unit TCJ sensor Strainer Air heat exchanger TC sensor Outer diameter of refrigerant pipe Distributor (Strainer incorporated) Gas side OA / 15. 9mm Liquid side OB / 9. 5mm * The refrigerating cycle of the indoor units differs according to the models to be combined. For the refrigerating cycles of the other indoor units, refer to the corresponding Service Manuals described in the list on the cover. Refrigerant pipe at gas side Outer dia. O A / Strainer Check joint TO sensor TD sensor TE sensor 4-way valve (STF-0401G) Muffler O 25 / O 25 / Outdoor unit Refrigerant pipe at liquid side Outer dia. O B / PMV (UKV-25D22) TS sensor Strainer x L210 x L180 Accumulator Rotary (2500cc) compressor (DA420A3F -21M) Heat exchanger 2 row 52 stages Outside : O 8 FP1. 3 flat fin / Inside : O 9. 52 FP1. 5 flat fin / Distributor R410A 2. 95kg Cooling Heating Pressure (MPa) Pd Standard Cooling Overload Low load Standard Heating Overload Low load 2. 55 3. 28 1. 76 2. 58 3. 43 2. 10 Ps 0. 98 1. 08 0. 76 0. 73 1. 18 0. 32 Discharge (TD) 69 82 47 68 75 88 Pipe surface temperature (oC) Suction (TS) 12 17 8 3 20 -14 Indoor heat exchanger (TC) 10 16 5 40 56 34 Outdoor heat exchanger (TE) 40 48 27 3 16 -13 Indoor/Outdoor temp. Compressor conditions revolutions per Indoor (DB/WB) (oC) second (rps) fan * 40 50 24 44 24 63 HIGH HIGH LOW HIGH LOW HIGH Indoor 27/19 32/24 18/15. 5 20/30/15/- Outdoor 35/43/-5/7/6 24/18 -15/(70%) * 4 poles are provided to this compressor. The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor. 2-34 RAV-SM1402CT-E / RAV-160UH-P Indoor unit TCJ sensor Strainer Air heat exchanger TC sensor Outer diameter of refrigerant pipe Distributor (Strainer incorporated) Gas side OA / 15. 9mm Liquid side OB / 9. 5mm * The refrigerating cycle of the indoor units differs according to the models to be combined. For the refrigerating cycles of the other indoor units, refer to the corresponding Service Manuals described in the list on the cover. Refrigerant pipe at gas side Outer dia. O A / Strainer Check joint TO sensor TD sensor TE sensor 4-way valve (STF-0401G) Muffler O 25 / O 25 / Outdoor unit Refrigerant pipe at liquid side Outer dia. O B / PMV (UKV-25D22) TS sensor Strainer x L210 x L180 Accumulator Rotary (2500cc) compressor (DA420A3F -21M) Heat exchanger 2 row 52 stages Outside : O 8 FP1. 3 flat fin / Inside : O 9. 52 FP1. 5 flat fin / Distributor R410A 2. 95kg Cooling Heating Pressure (MPa) Pd Standard Cooling Overload Low load Standard Heating Overload Low load 2. 76 3. 46 1. 77 2. 65 3. 33 2. 50 Ps 0. 91 1. 03 0. 78 0. 69 1. 08 0. 22 Discharge (TD) 74 82 48 75 74 98 Pipe surface temperature (oC) Suction (TS) 11 17 9 3 19 -22 Indoor heat exchanger (TC) 9 16 6 43 55 43 Outdoor heat exchanger (TE) 39 48 27 3 15 -18 Indoor/Outdoor temp. Compressor conditions revolutions per Indoor (DB/WB) (oC) second (rps) fan * 53 51 24 55 24 73 HIGH HIGH LOW HIGH LOW HIGH Indoor 27/19 32/24 18/15. 5 20/ 30/ 15/- Outdoor 35/43/-5/7/6 24/18 -15/(70%) * 4 poles are provided to this compressor. The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor. 2-35 2-3-6. Sensible Capacity Table RAV-SM562CT-E, SM802CT-E, SM1102CT-E, SM1402CT-E unit size outdoor air temp. [. . . ] Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 5-4 5-2. Drain up kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5-5 5-3. Twin kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5-1 5. Accessories line up 4-way Cassette Type Air discharge direction kit Auxiliary fresh air Flange TCB-FF101URE2 Super Long Life Filter TCB-LF1601UE2 TCB-BC1601UE High Efficiency Filter 65 TCB-UFM1601UE High Efficiency Filter 90 TCB-UFH1601UE Fresh air inlet Box TCB-GB1601UE2 Fresh air and Filter Chamber TCB-GFC1601UE2 Spacer for height adjustment TCB-SP1601UE Ceiling panel RBC-U21PG(W)-E2 Parts Name Ceiling panel Model name RBC-U21PG(W)-E2 Required accessory Notes Remarks Super Long Life Filter TCB-LF1601UE2 Dust collecting effect : 50% (Weight method) *Not valid in combination with TCB-FM1601UE, TCB-UFH1601UE and TCB-BC1601UE Dust collecting effect : 65% (NBS Colorimentric method) *Not valid in combination with TCB-LF1601UE2, TCB-UFH1601UE, TCB-FF101URE2 and TCB-BC1601UE Dust collecting effect : 90% (NBS Colorimentric method) *Not valid in combination with TCB-LF1601UE2, TCB-UFM1601UE, TCB-FF101URE2 and TCB-BC1601UE For fresh air intake by using the knockout hole of Fresh air and filter chamber. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-160UH-P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-160UH-P will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag