User manual TOSHIBA RAV-161-AHP SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-161-AHP. We hope that this TOSHIBA RAV-161-AHP user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAV-161-AHP.


Mode d'emploi TOSHIBA RAV-161-AHP
Download
Manual abstract: user guide TOSHIBA RAV-161-AHPSERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outdoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation Characteristic Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Is resistance value of TE sensor normal?YES Correct sensor mounting. NO Correct connector. Sensor error Replace NO Correct connector. Sensor error Replace Check outdoor P. C. Defect Replace ­ 71 ­ Check code [F31] Outdoor LED display <Display 1> <Display 2> Check and troubleshooting (Item without special mention Indicates part of outdoor unit. ) [EEPROM error] ¡ ¡ ¡ ¡ l l ¡ ¥ ¥ ¥ ¥ ¥ ¡ Check outdoor P. C. Defect Replace [H01] <Display 1> <Display 2> ¡ ¡ ¡ [Compressor break down] NO l l l ¥ l l l l Is power supply voltage normal?AC342 to 457V YES Is wire connection normal?Compressor lead (Board side, Compressor side), Reactor lead, Power supply lead YES Is it not abnormal overload?NO Correct power supply line. NO Check wire connection and correct it. YES Correct and clear the cause. Check outdoor P. C. Defect Replace [H02] <Display 1> <Display 2> ¡ ¡ ¡ ¡ [Compressor lock] l l l ¥ l l l l Is power supply voltage normal?AC342 to 457V YES Is wire connection normal?Confirm LED on outdoor P board to judge which error it is. (2) power supply error (Vdc), (3) high-pressure protective operation, (4) case thermo operation. <Display 1> <Display 2> ¡ ¡ ¡ ¡ ¡ ¡ l ¥ l l l l [High pressure SW system error] Power supply error (Vdc), High pressure protective operation, Case thermostat operation. Doesn't high pressure switch operate?YES Are parts of high pressure switch normal?YES Reset the power supply and then do a trial operation according to the season. B Cooling operation C Heating operation Open service valve fully. NO Parts check Defective Replace NO Is circuit wiring normal?YES B Cooling operation. Check Comp. IPDU PC board Defective Replace Does cooling outdoor fan normally operate?YES NO Is there no fan breakage or coming-off?Connection of connectors, Fan IPDU, Fan motor, Wiring. [. . . ] 43058288 43154177 43158207 43153006 43050425 43150319 43160565 43160579 43060859 4316V416 4316V391 4316V417 4316V398 43063325 43160590 43282001 43183020 43063248 43060700 Description Reactor, CH-56-4Z Relay, 480V, 20A Reactor, CH-68 PTC-Thermistor, ZPROYCE101A500 Sensor Ass'y, TC (F6) Sensor Ass'y, TD (F4) Terminal Block, 3P, 20A, AC250A Terminal, 30A, 4P Fuse Block, 30A, 250V, FH153-PB P Board Ass'y, MCC-1596, . C. Comp. -IPDU P Board Ass'y, MCC-1597, Fan-IPDU . C. Holder, Sensor Fuse, 6. 3A, AC250V Bushing Collar Supporter Ass'y Fuse, 10A, 250V 1104AT8-E 1104AT8-TR 1104AT7 1 1 1 1 3 2 1 1 1 1 1 1 1 1 3 5 5 2 1 RAV-SP 1104AT8ZG-E 1104AT8ZG-TR 1104AT7ZG 1 1 1 1 3 2 1 1 1 1 1 1 1 1 3 5 5 2 1 1104AT8Z-E 1104AT8Z-TR 1104AT7Z 1 1 1 1 3 2 1 1 1 1 1 1 1 1 3 5 5 2 1 ­ 133 ­ Outdoor Unit RAV-SP1404AT8-E, RAV-SP1404AT8Z-E, RAV-SP1404AT8ZG-E RAV-SP1404AT8-TR, RAV-SP1404AT8Z-TR, RAV-SP1404AT8ZG-TR RAV-SP1404AT7, RAV-SP1404AT7Z, RAV-SP1404AT7ZG 41, 42, 43 38, 39, 40 16 21 48 1 25 23 18 20 32, 33 29, 30 44, 45 22 17 47 46 37 27 34 31, 36 3, 28 26 19 7, 9, 35 15 13 6 14 8 2 24 4, 10 5, 11, 12 ­ 134 ­ Location No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Model name Part No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-161-AHP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-161-AHP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag