User manual TOSHIBA RBC-LG1 APPLICATION CONTROL MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RBC-LG1. We hope that this TOSHIBA RBC-LG1 user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RBC-LG1.


Mode d'emploi TOSHIBA RBC-LG1
Download
Manual abstract: user guide TOSHIBA RBC-LG1APPLICATION CONTROL MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] TCC-NET installation should follow Toshiba installation specifications. Terminals R1-R2 connect to fault monitoring or indication equipment according to the specified rating of the relay. The FDP2 is powered from the TCC-NET and requires no extra power supply. 18. 60 Indoor Unit 63. 00 87. 00 Fault Monitoring + Locked Cooling Preset 18 8 Units max ALL DIMENSIONS IN MM NOT TO SCALE FDP2 Description The FDP2-F is a monitoring and control interface for the Toshiba Digital Inverter and SMMS range of air-conditioners. TCC-NET TCC-NET D-BUS RELAY A B D1 D2 C R1 R2 Fault Reporting The FDP2-F Interface detects all indoor and outdoor faults occurring in TCC-NET compatible Toshiba air-conditioners and reports them by closing relay contacts R1-R2. [. . . ] The FDP2-F is connected on the TCC-NET network with or without a standard remote controller and detects any faults that can be displayed on the controller for up to 8 units. Red and Green LEDs Indicate Fault/No Fault state. A B To fault monitoring Fault Monitoring + Locked Heating Preset 23 Toshiba Remote Controller 8 Units max Control Functions GROUP CONTROL. Multiple FDP2 Interfaces can be connected to form large groups of units controlled from a single remote controller. Remote controller operation can be locked and various different preset run conditions can be sent from the FDP2. Pairs of FDPs can operate duty/standby control with 24 hour alternating duty, and changeover on fault. In conjuntion with an FDP2-BMS unit control can be achieved through potentiometer and volt-free contact inputs as well as via BMS integration. FDP2 interfaces can be supplied in custom configurations to suit specific applications. LED Functionality Normal Operation R G Key: OFF FLASHING ON Power-Up sequence Factory Configuration Power-Up sequence Custom Configuration R G R G No Fault State R G R G Unit Fault TCC-NET Holdoff. Address 1 to 15 are FDP2 SLAVE addresses that can be used to create large control groups. NETWORK INSTALLATION The D-Bus network requires a twisted pair cable connecting terminals D1 and D2 on each FDP2 as shown below. Terminal D1 must be connected to all other D1 terminals. Terminal D2 must be connected to all other D2 terminals. In addition the common terminal C on all devices must be connected together. If a shielded cable is used then the shield can be used for this purpose. The network must be installed as a point to point BUS configuration, Star and Ring connections must NOT be used. Address 0 (MASTER) 21 8 Units max 8 Units max D-BUS 16 FDP2 max Address 1 (SLAVE) D-BUS 16 FDP2 max Address 1 (SLAVE) The MASTER FDP2 can be configured using SW1 and SW2 to operate using one of the three preset modes Heat, Cool or Auto. [. . . ] The network must be installed as a point to point BUS configuration, Star and Ring connections must NOT be used. Address 0 (MASTER) 21 8 Units max 8 Units max D-BUS 16 FDP2 max Address 1 (SLAVE) D-BUS 16 FDP2 max Address 1 (SLAVE) The MASTER FDP2 can be configured using SW1 and SW2 to operate using one of the three preset modes Heat, Cool or Auto. Alternatively the MASTER can be configured for local control, in which case the remote controller attached to the MASTER FDP2 can be used to set the operating settings during master duty. ADDRESS 0 ADDRESS 1 TCC-NET D-BUS RELAY TCC-NET D-BUS RELAY A B D1 D2 C R1 R2 A B D1 D2 C R1 R2 PRESET CONTROL If the master is configured for Heat, Cool or Auto preset control then the FDP2 slave units will operate to the same settings as the master. The diagram below shows the system configured for the Cool preset. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RBC-LG1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RBC-LG1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag