User manual TOSHIBA REMOTEYE II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA REMOTEYE II. We hope that this TOSHIBA REMOTEYE II user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA REMOTEYE II.


Mode d'emploi TOSHIBA REMOTEYE II
Download
Manual abstract: user guide TOSHIBA REMOTEYE II

Detailed instructions for use are in the User's Guide.

[. . . ] RemotEye II ® User Manual Document Number: 50024-008 November, 2005 About This Manual This manual was written by the TOSHIBA Engineering and Marketing Groups. These groups are tasked with providing technical documentation for the RemotEye II system. Every effort has been made to provide accurate and concise information to you, our customer. This manual provides information on how to safely install, operate, and maintain your RemotEye II system. [. . . ] When the wires are closed to 'loopback' (the signal for the sensor), the sensor will detect the state as closed. The sensor will NOT activate the alarm for 'Normal Close' in this case, although the alarm will be activated if configured as 'Normal Open'. 'High Active' and 'Low Active' can be configured when a 'contact closure' type detector is attached. The administrator should connect the wire to the right side of the alarm (marked as arrow-in), and 8 to 12 VDC should be able to be detected by the EMD as 'high' state. Device Status The EMD can be configured as 'Disabled' or 'Auto'. The setup should be configured as 'Disabled' if an EMD is not attached to the port. The EMD type will be auto detected by the EMD if configured as 'Auto' and if the EMD is plugged into the port. 67 RemotEye II Management This menu allows the administrator to view the RemotEye II control parameters. Users have read-only privileges, whereas the administrators have read/write access. RemotEye II System Date and System Time This page shows the options on setting RemotEye II date and time. Date and Time These two fields show the current Date and Time of the RemotEye II. This can be changed to synchronize with a computer, an enquiry from a timeserver (NTP) or can be set manually. The date value is displayed in the MM/DD/YYYY format (i. e. , Jan 18, 2005 is 01/18/2005). The time value is displayed in the hh:mm:ss 24-hour format (i. e. , 8:30 p. m. Synchronize with computer time This field allows the administrator to synchronize the RemotEye II date and time to the computer clock, which the end user is using. Synchronize with NTP server NTP server IP and correct time zone must be selected to activate this option. After configuration, the RemotEye II will synchronize its time with the server periodically. If Daylight Saving Time is enabled, the time will be one hour earlier than NTP server time. Set Manually This field allows the administrator to configure the RemotEye II date and time manually. 68 RemotEye II Configuration This page allows the administrator to set the RemotEye II local network configuration parameters. Within the parameters, the Primary Time Server and the Secondary Time Server can only send out the correct time information to a client that has the Shutdown program installed. RemotEye II IP Address This field allows the administrator to set the IP address of the RemotEye II or to view the current setting (i. e. , 192. 9. 60. 229). RemotEye II Gateway Address This field allows the administrator to set the IP address of the gateway or to view the current setting (i. e. , 192. 9. 60. 10). RemotEye II Network Mask This field allows the administrator to set the subnet mask of the RemotEye II or to view the current setting (i. e. , 255. 255. 255. 0). [. . . ] When the transfer is complete the RemotEye II will reboot. 129 Upgrading RemotEye II Firmware from Windows via Serial Figure 29: Tugrade, RemotEye II Upgrade Utility via Serial The RemotEye II firmware may be upgraded from a Windows platform by performing the following procedure. A PC with a Windows 95/98, 2000, or NT operating system installed will be required for this procedure. On the PC, create a directory named Upgrade and copy the contents of the RemotEye II Upgrade CD-ROM to the Upgrade directory. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA REMOTEYE II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA REMOTEYE II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag