User manual TOSHIBA SATELLITE L870-16C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA SATELLITE L870-16C. We hope that this TOSHIBA SATELLITE L870-16C user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA SATELLITE L870-16C.


Mode d'emploi TOSHIBA SATELLITE L870-16C
Download
Manual abstract: user guide TOSHIBA SATELLITE L870-16C

Detailed instructions for use are in the User's Guide.

[. . . ] 11 EQUIPMENT SELECTION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 REFRIGERANT PIPING DESIGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 WIRING DESIGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (7) Arrange the cables so that the electric wires do not come to contact with high-temperature part of the pipe ; otherwise coating melts and an accident may be caused. (8) Do not turn on power of the indoor unit until vacuuming of the refrigerant pipe will finish. 2. For outdoor unit power supply · Select the power supply cabling and fuse of each outdoor unit from the following specifications: Cable 5-core, in conformance with Design 60245 IEC 66 · Do not connect them via the incorporated terminal block (L1, L2, L3, N). L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N Outdoor power supply 3-phase 380-415V, 50Hz 3. Electrical wiring design 3-phase Earth 50Hz 380-415V Earth leakage breaker hand switch Outdoor power source Indoor power source Single phase 50Hz 220-240V Earth leakage breaker power switch FS unit Pull box FS unit FS unit FS unit Indoor unit FS unit Indoor unit FS unit Indoor unit FS unit Indoor unit FS unit Indoor unit Indoor unit Indoor unit Indoor unit · Unit capacities and power supply wire sizes (Reference) Model MMYMAP0802FT8 MAP1002FT8 MAP1202FT8 Power supply wiring Wire size 3. 5 mm² (AWG #10) Max. 27 m Field fuse 30 A 30 A 30 A · Determine the wire size for indoor unit according to the number of connected indoor units downstream. · Observe local regulation regarding wire size selection and installation. 30 4. For Indoor unit power supply (Must be independent from outdoor unit power. ) Item Model All models of indoor units FS unit 2. 0mm² (AWG#14) Max. 20m Power supply wiring Wire size 3. 5mm² (AWG#12) Max. 50m Field fuse 15A Be sure to use the attached cable. If the length between indoor and FS unit exceeds 5 m, connect by using the connection cable kit (RBC-CBK15FE). (Sold separately) NOTE : The connecting length indicated in the table represents the length from the pull box to the outdoor unit when the indoor units are connected in parallel for power, as shown in the above illustration. Remote controller Individual air-conditioning units can be controlled remotely. 3. Network control The Super HRM control system can realize flexible centralized network control facility according to customer's various requirements, for both open network building control in combination with other building apparatus like elevator, fire alarm, lighting, etc. , and also for stand-alone air conditioning central control. These central control scheme is mainly established by advanced local server platform. 1-2. Group control One remote controller can control a maximum of 8 indoor units in group. 1-3. Two remote controller The units can be controlled from two locations using two remote controllers. 3-1. Weekly timer The units can be run on a weekly schedule using a "remote controller with weekly timer". Super HRM open network facility is applicable for major building management global standards. 2. Control via the central remote controller 2-1. Central control + individual control Up to 64 units can be controlled using the central remote controller and/or indoor remote controllers. Central control with Super MMS system is also available. 3-1-1. LONWORKS® The LONWORKS interface manages the Super HRM air conditioning system as a LON device to command a building computer message and to monitor the operation status. [. . . ] 1 pc. Insulator 350 16 Ø 28. 6 49 43 Ø 22. 2 50 58 Ø 34. 9 62 22 Ø 15. 9 50 1 pc. Ø 28. 6 Outer dia. Ø 28. 6 Ø 28. 6 Outer dia. 1 pc. Discharge gas side Accessory socket 70 Ø 28. 6 Insulator 10 Ø 12. 7 52 Ø 22. 2 52 Ø 19. 1 Outer dia. 2 pcs. Ø 22. 2 16 18 16 Ø 19. 1 80 Ø 22. 2 Outer dia. 1 pc. 89 Ø 28. 6 Closed pipe Ø 19. 1 53 Ø 19. 1 Outer dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA SATELLITE L870-16C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA SATELLITE L870-16C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag