User manual TRANSCEND TS2GCF45I-D QUICK INSTRUCTION GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRANSCEND TS2GCF45I-D. We hope that this TRANSCEND TS2GCF45I-D user guide will be useful to you.

Lastmanuals help download the user guide TRANSCEND TS2GCF45I-D.


Mode d'emploi TRANSCEND TS2GCF45I-D
Download
Manual abstract: user guide TRANSCEND TS2GCF45I-DQUICK INSTRUCTION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] TSxGMSA300 Built-in 15-bit/512Byte ECC (Error Correction Code) functionality ensures highly reliable of Placement · data transfer. Global wear-leveling algorithm eliminates excessive write operation and extends product life. · Support StaticDataRefresh & EarlyRetirement technology to monitor error bit level and react before data is corrupted. · · · Support S. M. A. R. T (Self-defined) Support Security Command Fully compatible with devices and OS that support the SATA 3Gb/s standard Non-volatile SLC/MLC Flash Memory for outstanding data retention · Dimensions Side W L H Millimeters 29. 85 50. 80 3. 5 Inches 1. 175 2. 000 0. 137 Transcend Information Inc. 1 V1. 3 TS2G~16GMSA500 TS16G~64GMSA300 Specifications Physical Specification Form Factor Storage Capacities Length Dimensions (mm) Width Height Input Voltage Weight Connector MO-300 2GB~64GB 50. 8 ± 0. 15 29. 85 ± 0. 15 3. 5 ± 0. 1 3. 3V ± 5% 9g PCI Express Mini Card Connector mSATA SSD Environmental Specifications Operating Temperature Storage Temperature Humidity Operating Non-Operating 0 to 70 -40 to 85 0% to 95% (Non-condensing) 0% to 95% (Non-condensing) Regulations Compliance CE, FCC and BSMI Performance Model P/N TS2GCF45I-D TS4GMSA500 TS2GCF45I-D TS16GMSA500 Read 50 MB/s 50 MB/s 100 MB/s 100 MB/s Write 25 MB/s 45 MB/s 80 MB/s 90 MB/s Random Read 50 MB/s 50 MB/s 80 MB/s 80 MB/s Random Write 8 MB/s 12 MB/s 15 MB/s 15 MB/s Performance Model P/N TS16GMSA300 TS32GMSA300 TS64GMSA300 Read 95 MB/s 95 MB/s 95 MB/s Write 15 MB/s 20 MB/s 30 MB/s 2 V1. 3 Random Read 55 MB/s 70 MB/s 55 MB/s Random Write 5 MB/s 5 MB/s 9 MB/s Transcend Information Inc. TS2G~16GMSA500 TS16G~64GMSA300 ® mSATA SSD Note:25 , Typical value, test on ASUS P4S800-MX, 1GB RAM, Windows XP Version 2002 SP2, benchmark utility HDBENCH (version 3. 4006), copied file 1GB Actual Capacity Model P/N TS2GCF45I-D TS4GMSA500 TS2GCF45I-D TS16GMSA500 TS16GMSA300 TS32GMSA300 TS64GMSA300 User Max. LBA 3, 865, 680 7, 732, 368 15, 465, 344 30, 932, 992 30, 932, 992 61, 865, 984 123, 731, 968 Cylinder 3, 835 7, 671 15, 343 16, 383 16, 383 16. 383 16, 383 Head 16 16 16 15 15 15 15 Sector 63 63 63 63 63 63 63 Power Requirements Input Voltage Mode Write(peak) Power Consumption Read(peak) Idle(peak) 3. 3V ± 5% Max. [. . . ] The host should allow for at least 873. 8 us (32768 nominal Gen1 Dword times) after detecting the release of COMWAKE to receive the first ALIGNP. This ensures interoperability with multi-generational and synchronous designs. If no ALIGNP is received within 873. 8 us (32768 nominal Gen1 Dword times) the host restarts the power-on sequence ­ repeating indefinitely until told to stop by the Application layer. Device locks ­ the device locks to the ALIGN sequence and, when ready, sends SYNCP indicating it is ready to start normal operation. Upon receipt of three back-to-back non-ALIGNP primitives, the communication link is established and normal operation may begin. Transcend Information Inc. 10 V1. 3 TS2G~16GMSA500 TS16G~64GMSA300 COMINIT mSATA SSD COMINIT always originates from the drive and requests a communication initialization. It is electrically identical to the COMRESET signal except that it originates from the device and is sent to the host. The device uses it to request a reset from the host in accordance to the sequence shown in Figure 6, below. Figure 6: cominit sequence Description: 1. Host/device are powered and operating normally with some form of active communication. Some condition in the device causes the device to issues a COMINIT 3. Device responds ­ The device detects the COMWAKE sequence on its RX pair and calibrates its transmitter (optional). Following calibration the device sends a six burst COMWAKE sequence and then sends a continuous stream of the ALIGN sequence starting at the device's highest supported speed. Parameter Information consists of the arrangement and value as shown in the following table. This command enables the host to receive the Identify Drive Information from the device. Identify Device Information Default Value Word Address 0 1 2 3 4 5 6 7-8 9 10-19 20 21 22 23-26 27-46 47 Default Value 044Ah XXXXh 0000h 00XXh 0000h 0240h XXXXh XXXXh 0000h aaaa 0002h 0002h 0004h aaaa aaaa 8001h Total Bytes 2 2 2 2 2 2 2 4 2 20 2 2 2 8 40 2 General configuration Default number of cylinders Reserved Default number of heads Obsolete Obsolete Default number of sectors per track Number of sectors per card (Word 7 = MSW, Word 8 = LSW) Obsolete Serial number in ASCII (Right Justified) Obsolete Obsolete Obsolete Firmware revision in ASCII. Big Endian Byte Order in Word Model number in ASCII (Left Justified) Big Endian Byte Order in Word Maximum number of sectors on Read/Write Multiple command Data Field Type Information Transcend Information Inc. 15 V1. 3 TS2G~16GMSA500 TS16G~64GMSA300 Word Address 48 49 50 51 52 53 54 55 56 57-58 59 60-61 62 63 64 65 66 67 68 69-75 76 77-79 80 81 82 83 84 85-87 88 89 90 91 92 Default Value 0000h 0F00h 4000h 0200h 0000h 0007h XXXXh 00XXh XXXXh XXXXh 01XXh XXXXh 0000h 0007h 0003h 0078h 0078h 0078h 0078h 0000h 0006h 000h 0080h 0000h 742Bh 550Ch 4002h XXXXh 047Fh 0001h 0000h 0000h FFFEh Total Bytes 2 2 2 2 2 2 2 2 2 4 2 4 2 2 2 2 2 2 2 14 2 6 2 2 2 2 2 6 2 2 2 2 2 Reserved Capabilities Capabilities PIO data transfer cycle timing mode Obsolete Field Validity Current numbers of cylinders Current numbers of heads Current sectors per track mSATA SSD Identify Device Information Default Value Data Field Type Information Current capacity in sectors (LBAs)(Word 57 = LSW, Word 58 = MSW) Multiple sector setting Total number of sectors addressable in LBA Mode Reserved Multiword DMA transfer. Supports MDMA Mode 0, 1, and 2 Advanced PIO modes supported Minimum Multiword DMA transfer cycle time per word. In PC Card modes this value shall be 0h Recommended Multiword DMA transfer cycle time. In PC Card modes this value shall be 0h Minimum PIO transfer cycle time without flow control Minimum PIO transfer cycle time with IORDY flow control Reserved Serial ATA capacities Support Serial ATA Gen1 Support Serial ATA Gen2 Reserved Minor version number (ATAPI-7) Minor version number Command sets supported 0 Command sets supported 1 Command sets supported 2 Features/command sets enabled Ultra DMA Mode Supported and Selected Time required for Security erase unit completion Time required for Enhanced security erase unit completion Current Advanced power management value Master Password Revision Code Transcend Information Inc. 16 V1. 3 TS2G~16GMSA500 TS16G~64GMSA300 Word Address 93-127 128 129-159 160 161 162 163 164 165-175 176-255 Default Value 0000h 0001h 0000h 81F4h 0000h 0000h 0000h 0000h 0000h 0000h Total Bytes 70 2 64 2 2 2 2 2 22 140 Reserved Security status Vendor unique bytes Power requirement description Reserved Key management schemes supported mSATA SSD Identify Device Information Default Value Data Field Type Information CF Advanced True IDE Timing Mode Capability and Setting Reserved Reserved Reserved READ DMA (C8h) Read data from sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. A sector count of zero requests 256 sectors. READ MULTIPLE (C4h) This command performs similarly to the Read Sectors command. Interrupts are not generated on each sector, but on the transfer of a block, which contains the number of sectors defined by a Set Multiple command. READ SECTOR(S) (20h) This command reads 1 to 256 sectors as specified in the Sector Count register from sectors that is set by Sector number register. A sector count of 0 requests 256 sectors. The transfer beings specified in the Sector Number register. READ VERIFY SECTOR(S) (40h/41h) This command verifies one or more sectors on the drive by transferring data from the flash media to the data buffer in the drive and verifying that the ECC is correct. [. . . ] Once this command has been executed, the following commands to update a lock result in the Aborted Command error: · SECURITY SET PASSWORD · SECURITY UNLOCK · SECURITY DISABLE PASSWORD · SECURITY ERASE PREPARE · SECURITY ERASE UNIT The drive exits from Frozen mode upon a power-off or hard reset. If the SECURITY FREEZE LOCK command is issued when the drive is placed in Frozen mode, the drive executes the command, staying in Frozen mode. SMART Feature Set Transcend IDE SSD supports the SMART command set and define some vendor-specific data to report spare/bad block numbers in each memory management unit. Individual SMART commands are identified by the value placed in the Feature register. Table shows these Feature register values. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TRANSCEND TS2GCF45I-D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TRANSCEND TS2GCF45I-D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag