User manual TRITON T40I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRITON T40I. We hope that this TRITON T40I user guide will be useful to you.

Lastmanuals help download the user guide TRITON T40I.


Mode d'emploi TRITON T40I
Download
Manual abstract: user guide TRITON T40I

Detailed instructions for use are in the User's Guide.

[. . . ] T40i booster pump Installation and operating instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180209H November 2004 T40i CONTENTS Important safety information Introduction Specifications Key to main components Site requirements ­ water Site requirements ­ electrical Fitting to the wall Hose connections Electrical connections Replacing the cover and testing Operating Maintenance Spare parts Fault finding Guarantee, service policy etc. Page 1 2 2 3 4 5 6 7 8 9 10 10 11 12 rear cover To check the product suitability for commercial and multiple installations, please contact Triton's specification advisory service before installation. Telephone: 0870 067 3767 Facsimile: 0870 067 3334 E mail: technical@tritonshowers. co. uk T40i PLEASE READ THIS IMPORTANT SAFETY INFORMATION 1 GENERAL 2 ELECTRICAL 1. 1 Products manufactured by Triton are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. 1. 2 DO NOT operate the unit if it is frozen, or suspected of being frozen. 1. 3 Switch off the electrical supply at the mains before removing the cover. [. . . ] Decide on the cable entry position, either top or rear. If top entry position is chosen, the cut-out in the backplate must be removed (fig. 7). Loosely connect the flexible hose supplied to the T40i inlet connection and the mixer valve outlet. Using the backplate as a template, hold it against the wall, making sure there is some slack in the hose and mark the position of the fixing holes (fig. 8). Remove the flexible hose from the T40i and mixer valve. Drill and plug to suit the fixing screws supplied. (The wallplugs provided are suitable for most brick walls ­ use an appropriate masonry drill, but if the wall is plasterboard or a soft building block, you must use special wallplugs and an suitable drill bit). Screw the top fixing screw into position leaving the base of the screw head protruding 6mm out from the wall. Hook the backplate over the top screw and fit the bottom fixing screw into position. The bottom fixing hole is elongated to allow for out of square adjustment. Tighten both screws when correctly positioned. Fig. 8 6 T40i HOSE CONNECTIONS Fitting to: Bath tap/mixer valve (fig. 2) Mixer valve (fig. 3) Push on with blender valve (fig. 4) Remove the existing sprayhead flexible hose from bath tap/mixer valve/blender mixer arrangement. Screw one end of the flexible hose supplied, to the T40i inlet connection using one of the sealing washers to seal the joint. Screw the other end of the flexible hose to the mixer outlet using the washer provided to seal the joint. Screw the sprayhead flexible hose to the outlet of the T40i pump using the washer provided to seal the joint. Hold the end of the hose to waste and turn the water on to flush the system and to check for leaks. Replace the sprayhead and turn the water on again. Leave running to waste until a smooth (even if poor) flow of water is obtained. Turn off the water. Fig. 9 Existing hose Hose supplied Fitting to: Push-on type connection (fig. 5) and (fig. 9) Unscrew the sprayhead from the existing hose then connect the hose to the T40i inlet. Note: This is only possible if the hose terminates with a ½" BSP connection. Connect the hose supplied to the T40i outlet using the washer provided to seal the joint. Hold the end of the hose to waste and turn the water on to flush the system and to check for leaks. [. . . ] 3 If a service call is required it will be booked and the date of call confirmed. In order to expedite your request, please have your postcode available when booking a service call. 4 It is essential that you or an appointed representative (who must be a person of 18 years of age or more) is present during the service engineer's visit and receipt of purchase is shown. 5 A charge will be made in the event of an aborted service call by you but not by us, or where a call under the terms of guarantee has been booked and the failure is not product related (i. e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TRITON T40I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TRITON T40I will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag