[. . . ] HighVac Series Vacuum Pumps High Vacuum Venturi Pump up to 29. 5"Hg with Silencer HighVac Series: HVP 100, 200, 300 Ideal Applications: · Process control · Vessel evacuation · HVAC applications · Degassing Features/Benefits: · High performance ­ powerful vacuum up to 29. 5"Hg [999mbar] · Fast response time ­ no delay due to long plumbing lines; mounts in-line and installs close to vacuum point · Efficient minimal air consumption · Compact, lightweight and modular ­ easy to install HVP-100 degassing viscous liquids such as silicone and other mold compounds · Safe operation ­ no electricity needed at the pump · Reliable, trouble-free operation ~ No moving parts to wear ~ No flap valves to stick open ~ No maintenance ~ No downtime HVP Series Standard Pump: The HighVac Series of air-powered venturi vacuum pumps generate vacuum levels up to 29. 5" Hg [999mbar] and offer a wide range of vacuum flow rates. The high vacuum level and compact size of the HVP pump allows you to incorporate smaller and more efficient components in your design. [. . . ] When complete, simply download the CAD drawing in any one of 13 different CAD formats and insert it right into your design. VACUUM PUMP VACCON MEDFIELD, MA 800-848-8788 L F AIR FLOW M E D F I E L D, M A 800 -848 -8788 ST-8A AIR FLOW ØS U ST SERIES SILENCER ST-8A E "A" AIR SUPPLY PORT K M N R 3X Ø D MOUNTING HOLES T Get the pump you need, in the format you like! Vacuum Pumps - High Vacuum 158 HVP-100 HVP-200 HVP-300 Specifications: Weight Noise Level 9oz [255g] 71 dB Specifications: Weight Noise Level 1 lb 11 oz [765g] 74 dB Imperial Dimensions (in. ) Specifications: Weight Noise Level 2 lb [907g] 79 dB Model # HVP-100 HVP-200 HVP-300 A 1/4 NPTF 1/4 NPTF 3/8 NPTF B 1/8 NPTF 1/4 NPTF 1/4 NPTF C 1/4 NPTF 1/2 NPTF 1/2 NPTF D 0. 12 0. 21 0. 21 E 0. 38 0. 50 0. 50 F 0. 38 0. 75 0. 75 H 2. 28 4. 02 4. 02 J 0. 75 1. 00 1. 00 K 0. 09 0. 20 0. 20 L 0. 67 N/A N/A M 1. 78 2. 20 2. 50 N N/A 3. 70 4. 00 P 3. 20 4. 00 5. 00 R 5. 06 7. 57 9. 81 S 0. 75 1. 00 1. 25 HVP Pump Standard Specifications: Pump Material: Cartridge Material: Medium: Operating Temperature: Operating Pressure: Anodized Aluminum (For silencer material, see Silencer section ­ page 235. Nylon, Buna-N (Other materials available, see page 7) Filtered (50 Micron) un-lubricated, noncorrosive dry gases -30°~250° F [-34°~121°C] 80 PSI [5. 5 BAR] standard or 60 PSI [4. 0 BAR] ­ Consult Factory for other operating pressures HVP Pump Installation Instructions: Vacuum Line & Supply Line ­ HVP100/200: 3/8" O. D. [10mm] tube recommended Vacuum Line Filtration ­ HVP100/200: Vacuum Line & Supply Line ­ HVP300: Vacuum Line Filtration ­ HVP300: Mounting Holes: Typically filters are not required, if desired Vaccon recommends ­ VF250. [16mm] tube recommended Typically filters are not required, if desired Vaccon recommends ­ VF375. HVP-100 = 4-40 [M3], HVP-200/300 = #10-32 [M5] screws Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon. com HighVac Series Vacuum Pumps HVP Series - Performance Data Model # HVP-100 HVP-200 HVP-300 Model # HVP-100 HVP- 200 HVP-300 Air Consumption SCFM 4. 90 8. 60 22. 00 O"Hg 1. 30 3. 45 6. 00 O"Hg 0. 00 0. 00 0. 00 3"Hg 1. 20 3. 25 5. 10 3"Hg 6. 50 2. 30 1. 20 6"Hg 1. 10 3. 05 Imperial ­ Vacuum Flow (SCFM) vs. Vacuum Level ("Hg) 9"Hg 12"Hg 15"Hg 18"Hg 21"Hg 1. 00 2. 75 0. 90 2. 45 0. 90 2. 05 0. 90 1. 90 0. 80 1. 60 24"Hg 0. 60 1. 30 27"Hg 0. 30 0. 90 0. 90 27"Hg 135. 50 67. 50 39. 50 29. 5"Hg 0. 00 0. 00 0. 00 29. 5"Hg 281. 30 125. 00 98. 10 4. 70 4. 40 4. 10 3. 60 3. 00 2. 60 1. 80 Evacuation Time in Seconds based on 1 Cubic Foot Volume/"Hg 6"Hg 9"Hg 12"Hg 15"Hg 18"Hg 21"Hg 24"Hg 12. 30 3. 80 2. 10 18. 90 6. 50 3. 40 32. 50 10. 20 5. 20 40. 00 14. 10 7. 70 52. 50 20. 00 11. 50 72. 50 29. 50 16. 30 98. 00 44. 00 24. 00 Note 1: Standard operating pressure for Vaccon pumps is 80 PSI [5. 5BAR]. Pumps can be factory modified to run at other operating pressures i. e. The values shown in the performance chart will remain the same for all operating pressures. Note 2: Evacuation speed is linear with volume, a 2 cu. volume will take twice as long to evacuate as a one cu. [. . . ] volume. Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon. com 159 Vacuum Pumps - High Vacuum Air Consumption L/min O mbar Metric ­ Vacuum Flow (L/min) vs. Vacuum Level (mbar) 102 mbar 203 mbar 305 mbar 406 mbar 508mbar 609 mbar 711 mbar 813 mbar 914 mbar 999 mbar HighVac Series Vacuum Pumps Vacuum Pumps - High Vacuum 160 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VACCON HVP-300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VACCON HVP-300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag