User manual VAISALA BAROCAP DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA BAROCAP. We hope that this VAISALA BAROCAP user guide will be useful to you.

Lastmanuals help download the user guide VAISALA BAROCAP.


Mode d'emploi VAISALA BAROCAP
Download
Manual abstract: user guide VAISALA BAROCAPDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. vaisala. com Vaisala BAROCAP® Pressure Module Features/Benefits Based on silicon capacitive sensor technology - BAROCAP® Excellent accuracy, repeatability, and long-term stability Wide operating temperature range Calibration traceable to international standards (NIST) An optional barometer module for the Vaisala Data Logger QML201 The Vaisala BAROCAP® Pressure Module has excellent accuracy, repeatibility and long-term stability over a wide range of operating temperatures. [. . . ] The pressure range of the sensor is 500 . . . 1100 hPa and operating temperature range -40 . . . +60 °C. Pressure module located on the central processing unit QML201. Technical data Property Description/value 500 . . . 1100 hPa ± 0. 10 hPa ± 0. 03 hPa ± 0. 03 hPa ± 0. 15 hPa ± 0. 20 hPa ± 0. 10 hPa ± 0. 25 hPa ± 0. 10 hPa/year -40 . . . +60 °C 0. 10 hPa Pressure range Linearity * Hysteresis * Repeatability * Calibration uncertainty ** Accuracy at +20 °C (+68 °F) *** Temperature dependence **** Total accuracy at -40 . . . +140 °F) Long-term stability Operating temperature range Resolution * Defined as ± 2 standard deviation limits of endpoint non-linearity, hysteresis error or repeatability error. ** Defined as ± 2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of endpoint non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ± 2 standard deviation limits of temperature dependence over the operating temperature range. For more information, visit www. vaisala. com or contact us at sales@vaisala. com Ref. [. . . ] All specifications -- technical included -- are subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA BAROCAP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA BAROCAP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag