User manual VAISALA GMW116 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA GMW116. We hope that this VAISALA GMW116 user guide will be useful to you.

Lastmanuals help download the user guide VAISALA GMW116.


Mode d'emploi VAISALA GMW116
Download

You may also download the following manuals related to this product:

   VAISALA GMW116 QUICK REFERENCE GUIDE (1060 ko)

Manual abstract: user guide VAISALA GMW116DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. vaisala. com GMW116 Carbon Dioxide and Temperature Transmitter for Ventilation Control The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116. Features/Benefits Compact dual-parameter transmitter: measures both CO2 and T Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing Advanced, single-beam, dual wavelength measurement with no moving parts Excellent long-term stability Ideal for ventilation control in all types of occupied spaces including those with aroundthe-clock occupancy No need for temperature compensation The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116 is the compact-size transmitter that measures both carbon dioxide and temperature. [. . . ] The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements. The GMW116 Transmitter is designed especially for demand controlled ventilation applications with CO2 measurement range of 0 . . . With GMW116 there is no need for temperature compensation. The ideal gas temperature behaviour is taken into account automatically. Technical data Performance CO2-measurement range Temperature measurement range Accuracy (including repeatability, nonlinearity and calibration uncertainty) Long-term stability Response time T90 Temperature dependence Pressure dependence, typical Temperature measurement accuracy Warm-up time Product lifetime 0 . . . +50 °C ± (2 % of range + 2 % of reading ± 5 % of range/5 years 1 min compensated +0. 15 % of reading/hPa ± 0. 7 °C at 25 ° 1 min, 10 min for full. specification > 10 years Dimensions Operating environment Temperature 0 . . . 1200 hPa Electromagnectic compatibility Complies with EMS standard EN61326-1, Generic Environment Inputs and outputs Operating voltage Power consumption Outputs 24 V (±20 %) AC/DC <2 W 0 . . . 10 V Housing Material Weight Cover and base colour Fire resistance Ingress protection ABS/PC blend plastics 120 g white RAL 9003 UL94 V0 IP30 For more information, visit www. vaisala. com or contact us at sales@vaisala. com Ref. [. . . ] All specifications -- technical included -- are subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA GMW116

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA GMW116 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag