User manual VAISALA HMT360N BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA HMT360N. We hope that this VAISALA HMT360N user guide will be useful to you.

Lastmanuals help download the user guide VAISALA HMT360N.


Mode d'emploi VAISALA HMT360N
Download
Manual abstract: user guide VAISALA HMT360NBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] +358 9 894 91 Fax: +358 9 8949 2485 Email: industrialsales@vaisala. com www. vaisala. com/HMT360N HMT360 Series Dewpoint and Temperature Transmitters for Natural Gas Moisture Features/Benefits · · · · · · · · · The HMT362, HMT364 and HMT368 are innovative and reliable instruments for measuring moisture in natural gas. Vaisala HUMICAP® Sensor features high accuracy, excellent long-term stability, and negligible hysteresis Excellent performance in harsh conditions; tolerates glycol and water spikes Measures dewpoint of water, also outputs lb/MMscf, ppmv and T Safe operation with the entire transmitter in hazardous areas: Division 1 and 2 (USA, Canada), Category 1 / Zone 0 (EU) One-year maintenance interval saves lifetime costs Interchangeable probes Direct pipeline installation possible Sampling cell option NIST traceable (certificate included) The Vaisala HUMICAP® Dewpoint and Temperature Transmitter Series HMT360 is a reliable instrument for measuring moisture in natural gas. An accurate moisture measurement is critical for preventing pipeline failures and ensuring the quality of the gas. be sent to Vaisala. [. . . ] 320 mg/Nm3 parts per million by volume 0 . . . 500 ppmv Canada (CSA) Class I, Division 1 and Division 2, Groups A, B, C, D; Class II, Division 1 and Division 2, Groups G and Coal Dust; Class III CSA File No: 213862 0 000, CSA Report: 1300863 Safety factors: Tamb= 60 °C, T4, Intrinsically safe when connected as per Installation Drawing DRW213478. Russia (STV) Ex ia IIC T4 Certificate No. ROSS FI. GB04. V00634 Safety factors Ui = 28 V, Ii = 100 mA, Pi = 700 mW Ci = 1 nF, Li = 0 H, Tamb= -20 °C . . . +60 °C Mechanics Connections Operating environment Temperature range operating storage Pressure range -20 . . . 158 °F) see probe specifications screw terminals, 0. 33 . . . 2. 0 mm2 wires (AWG 14-22) Cable bushing for 7. 5. . 12mm or 10. . 15mm cable diameters (M20x1, 5) Conduit fitting NPT 1/2" (M20) Housing material G-AlSi10Mg (DIN 1725) Housing classification IP66 (NEMA 4X) Housing weight 950 g Complies with EMC standard EN61326-1, Electrical equipment for measurement, control and laboratory use EMC requirements; Industrial environment. IEC 1000-4-5 complies only when using external EXi approved surge arrester on safe area. Options and accessories Inputs and outputs Operating voltage 12 . . . 28 VDC with serial port (service mode) 15 . . . 20 mA, one standard, one optional Typical accuracy of analog outputs at +20 °C ±0. 05% full scale Typical temperature dependence of analog outputs 0. 005% / °C (0. 005% / °F) full scale Analog outputs connection via safety barriers RS232C serial output for service use connector type RJ45 Display two-line LCD character size (1st line/2nd line) 12 mm/10 mm Additional analog output 4 . . . 20 mA Ball valve ISO 1/2 with welding joint ( for HMP368) BALLVALVE-1 pressure range at +20 °C (+68 °F): 0 . . . 10 bar (145 psia) Serial interface cable for PC connectors RJ45 - D9 female 25905ZZ Sampling cell for HMP362 HMP302SC Rain shield 215109 Calibration adapter for HMK15 211302 Sintered stainless steel filter HM47280 Galvanic isolator (EU) 212483 Zener Barrier (USA & Canada) 210664 Classification with current outputs Europe / CENELEC (PTB) EU (94/9/EC, ATEX100a) Safety factors Environmental specifications Tamb Pamb EEx ia IIC T4 PTB 00 ATEX 2112 X Ui = 28 V, Ii = 100 mA, Pi = 0. 7 W Ci = 1 nF, Li = 0 H -20 . . . [. . . ] 13. 5 mm (0. 53'') Installation 17225 Fitting body ISO 1/2 solid structure DRW212076SP Fitting body NPT 1/2 solid structure NPTFITBODASP Ball valve ISO 1/2 with welding joint BALLVALVE-1 Pressure range Probe cable length Probe length Probe diameter 41 (1. 61) Ø13. 5 (0. 53) Technical Data R ½ ISO 7/1 or NPT½" 41 - 149/371 (1. 61 - 5. 87/14. 6)* 194/416 (7. 64/16. 4) 232/454 (9. 13/17. 9) M22×1. 5 or NPT 1/2" ø12. 5 (0. 49) The HMP362 probe is designed for flange mounting and the sampling cell. The HMP362 has the highest pressure tolerance of the optional probes. 58. 7 (2. 31) 45° ø24 45° 1/8"-27 NPT . 5 71 (2. 80) 14 (0. 55) The HMP368 probe enables flexible installation in pressurized pipelines through the ball valve set. Length for standard / optional probes *freely user adjustable length HMP368 probe 22 Vaisala Instruments Catalog 2009 Ref. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMT360N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMT360N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag