User manual VAISALA PTB210 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA PTB210. We hope that this VAISALA PTB210 user guide will be useful to you.

Lastmanuals help download the user guide VAISALA PTB210.


Mode d'emploi VAISALA PTB210
Download
Manual abstract: user guide VAISALA PTB210DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. vaisala. com PTB210 Digital Barometer The PTB210 paired with the SPH10 Static Pressure Head. The Vaisala BAROCAP® Digital Barometer PTB210 is a reliable outdoor barometer that withstands harsh conditions. For harsh environments The Vaisala BAROCAP® Digital Barometer PTB210 is ideal for outdoor installations and harsh environments. The barometers are designed to operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water. The PTB210 barometers are ideal for use in applications such as weather stations, data buoys and ships, airports, and agrology. [. . . ] 1100 hPa pressure ranges with serial output Different scalings between 500 . . . 1100 hPa with analog output Electronics housing IP65 protected against sprayed water Accurate and stable measurement NIST traceable (certificate included) Accurate and stable measurement All the PTB210 barometers are digitally adjusted and calibrated by using electronic working standards. A higher accuracy barometer, that is fine-tuned and calibrated against a Technical data Operating range (1hPa=1mbar) Pressure range (order specified) serial output analog output 500 . . . +140 °F) non-condensing General (· Factory setting) Serial output Operating temperature range Humidity range Current consumption normal mode power down mode shutdown mode Shutdown Settling time at power up Serial I/O (factory setting·) Accuracy Serial output (units in hpa) Pressure range Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F)*** Temperature dependence**** Total accuracy*** -40 . . . +140 °F) Long term stability (hPa/year) analog output 500 . . . 1100 Class A Class B ± 0. 10 ± 0. 15 ± 0. 05 ± 0. 05 ± 0. 05 ± 0. 05 ± 0. 07 ± 0. 15 ± 0. 15 ± 0. 20 ± 0. 20 ± 0. 20 ± 0. 25 ± 0. 30 ± 0. 10 ± 0. 10 50 . . . 1100 ± 0. 20 ± 0. 10 ± 0. 10 ± 0. 20 ± 0. 35 ± 0. 40 ± 0. 50 ± 0. 20 parity data bits stop bits Baud rate Response time Resolution analog output < 15 mA· < 0. 8 mA 0. 2 mA ON/OFF 2s RS232C RS232C /TTL (optional) RS485, non isolated (optional) none, even·, odd 7·, 8 1·, 2 1200, 2400, 4800, 9600·, 19200 1 s· 0. 01 hPa (1 measurement/s) 0. 03 hPa (10 measurements/s) 0 . . . 2. 5 VDC (order specified) < 8 mA 0. 2 mA ON/OFF 500 ms 300 µV 3 measurements/s Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F)*** Temperature dependence**** Total accuracy*** -40 . . . +140 °F) Long term stability * ± 0. 20 hPa ± 0. 05 hPa ± 0. 05 hPa ± 0. 15 hPa ± 0. 30 hPa ± 0. 50 hPa ± 0. 60 hPa ± 0. 10 hPa/year Outputs Current consumption normal mode shutdown mode Shutdown Response time Resolution Measurement rate all modelS Defined as the ±2 standard deviation limits of end point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of end point non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. Supply voltage (reverse polarity protected) with RS232/TTL output 5 . . . 28 VDC with RS485 or analog output 8 . . . Pressure connector M5 (10-32) internal thread Pressure fitting barbed fitting for 1/8" I. D. [. . . ] any logos and/or product names are trademarks of Vaisala or its individual partners. the reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. all specifications -- technical included -- are subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA PTB210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA PTB210 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag