User manual VAISALA PTU200MIK1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA PTU200MIK1. We hope that this VAISALA PTU200MIK1 user guide will be useful to you.

Lastmanuals help download the user guide VAISALA PTU200MIK1.


Mode d'emploi VAISALA PTU200MIK1
Download
Manual abstract: user guide VAISALA PTU200MIK1

Detailed instructions for use are in the User's Guide.

[. . . ] All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale. _________________________________________________________________________________ Table of contents CHAPTER 1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CHAPTER 2 PRODUCT DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 CHAPTER 3 PTU200MIK1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation when static pressure head is on the right side . 5 Installation when static pressure head is on the left side. . . . 7 Connections in the transmitter box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Probe installations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 HMP45 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 HMP233 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 HMP243 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 CHAPTER 4 PTU200TRIPOD INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 CHAPTER 5 DIMENSIONS in mm (in inches). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Static pressure head on the left side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Static pressure head on the right side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 VAISALA __________________________________________________________________________ 1 USER'S GUIDE_______________________________________________________________________ CHAPTER 1 GENERAL INFORMATION Safety Throughout the manual, important safety considerations are highlighted as follows: WARNING Warning denotes a serious hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in injury to or death of personnel. CAUTION Caution denotes a hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or the entire product. NOTE Note highlights important information. It calls attention to an essential procedure, practice, condition or the like. Warranty Vaisala issues a guarantee for the material and workmanship of this product under normal operating conditions for one (1) year from the date of delivery. [. . . ] Fasten it to the plate with the slot headed screws (M5x16 DIN84, provided) Boom adapter 4. Insert the boom adapter into on support arm. Attach the support arms and fasten with two screws. VAISALA __________________________________________________________________________ 5 USER'S GUIDE_______________________________________________________________________ 7. Attach the pressure hose end to the threaded nipple of the pressure head. 8. Push the installation plate into the support arm. 9. Fasten the static pressure head to the end of the support arm (and installation plate) by using the two screws. 6. Thread the pressure hose through the support arm. 10. Connect the free end of the pressure hose to the hose coupling on backside of the transmitter box. This is to prevent the condense water block the tube as it freezes. 6 ___________________________________________________________________ NOVEMBER 2001 CHAPTER 3___________________________________________________ PTU200MIK1 INSTALLATION Installation when static pressure head is on the left side Boom adapter 3. Mount the support arm on the upper clamp. Fasten it by using the plate, two hex bolts and washers for the attachement as shown in the figure. Insert the boom adapter into on support arm. 2 Join the two support arms by using two screws. 4. Mount the radiation shield as instructed on page 5. Mount the static pressure head and thread the pressure hose as instructed on page 6. 6. Connect the free end of the pressure hose to the hose coupling on backside of the transmitter box. This is to prevent the condense water block the tube as it freezes. VAISALA __________________________________________________________________________ 7 USER'S GUIDE_______________________________________________________________________ Connections in the transmitter box 1. Mount the PTU200 transmitter on the back plate of the transmitter box and attach it with the four Allen screws. 2. Thread the cables through the holes of the box and the gasket body. Allen key for opening the transmitter 3. Thread the cables through the hole in the bottom of the box. (The diameter of the bottom hole is 35 mm) 4. Thread the cables through the different parts of the gasket fitting in the order shown in the figure. Take care that the positions of the parts are correct. There are two alternative rubber sealings, one for the cables of 4 and 6 mm and one for the cables of 6 and 6 mm. Press the cable through the vertical cutting of the rubber sealing. [. . . ] The handle of the screw is under the center of the stand. To release the leg, lift the grip upwards. Adjust the leg to desired length and lock it by pressing the grip downwards. Open Locked Use the clamps without the fitting rings to attach the PTU200MIK to the pole. Certain meteorological standards define the altitude for the pressure measurement. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA PTU200MIK1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA PTU200MIK1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag