User manual VDO RESSURE GAUGE INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VDO RESSURE GAUGE. We hope that this VDO RESSURE GAUGE user guide will be useful to you.

Lastmanuals help download the user guide VDO RESSURE GAUGE.


Mode d'emploi VDO RESSURE GAUGE
Download
Manual abstract: user guide VDO RESSURE GAUGEINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] _ LED Illumination _ Flush mount possibility _ High reliability Picture: Ammeter Concept Housing Bezel Lens Dial Pointer Illumination Warning LED Mounting Connection PC; flame retarding (UL94) PC or ABS; several colors and shapes (see table) PMMA; double lens backlit; different colors (see table) backlit, white on black dials; red on white dials Dial: LED amber (605nm) Pointer: LED red (632nm) red (632nm) spinlock Nut; locking height 0, 5mm ­ 20mm, optional Studs and Bracket; locking height 2 ­ 15mm 8 pin MQS connector system VDO ­ A trademark of the Continental Corporation Viewline Ammeter gauges Technical Data Installation depth Installation diameter Deflection angle Operating Voltage Accuracy Current consumption Operating temperature Storage temperature 50mm 52mm 240° 8 ­ 32 Volt < 2, 5 % of the full scale reading < 140 mA, including Warning LED -30°C to +80°C; plated bezels (chrome) -30°C to +70°C -40°C to +80°C for 48h; plated bezels (chrome) -40°C to +70°C +90°C for 1h Range Transformation time Retention time Range Rel. [. . . ] _ LED Illumination _ Flush mount possibility _ High reliability Picture: Ammeter Concept Housing Bezel Lens Dial Pointer Illumination Warning LED Mounting Connection PC; flame retarding (UL94) PC or ABS; several colors and shapes (see table) PMMA; double lens backlit; different colors (see table) backlit, white on black dials; red on white dials Dial: LED amber (605nm) Pointer: LED red (632nm) red (632nm) spinlock Nut; locking height 0, 5mm ­ 20mm, optional Studs and Bracket; locking height 2 ­ 15mm 8 pin MQS connector system VDO ­ A trademark of the Continental Corporation Viewline Ammeter gauges Technical Data Installation depth Installation diameter Deflection angle Operating Voltage Accuracy Current consumption Operating temperature Storage temperature 50mm 52mm 240° 8 ­ 32 Volt < 2, 5 % of the full scale reading < 140 mA, including Warning LED -30°C to +80°C; plated bezels (chrome) -30°C to +70°C -40°C to +80°C for 48h; plated bezels (chrome) -40°C to +70°C +90°C for 1h Range Transformation time Retention time Range Rel. Humidity DIN_EN 61000-6-3 DIN_EN 61000-6-1 DIN_EN 61000-6-4 DIN_EN 61000-6-2 EN 60945 GL, Category C, F (under preparation) Sinus 2g; 10-500Hz; duration 16h Noise 3g; 10-1000Hz, duration 8h continuous Single shock Free fall 25g; 6ms; 1Hz 100g; 11ms 1m; 3 times -40°C to +85°C; plated bezels (chrome) -40°C to +70°C 10 seconds 2h +25°C to +55°C 95% Temperature shock Climatic test EMC in conformity with Standards Vibration Mechanical shock Chemical resistance against - preservative agent - preservative agent remover - cold cleaner - methylated spirit - interior cleaner - drinks containing caffeine and tannin Nominal position Protection class NL 0 to NL 85 (DIN16257) according to IEC 60529 Front: IP67 (in Nominal position) Rear: IP52 (in Nominal position) Reverse polarity protection yes, 5 minute Short circuit protection yes, 1 minute Technische Änderungen vorbehalten 12/09 Technical details subject to change 2-3 The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. Offenders will be held liable for the payment of damages. All right reserved in the event of the grant of a patent, utility model or design. [. . . ] Offenders will be held liable for the payment of damages. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VDO RESSURE GAUGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VDO RESSURE GAUGE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag