User manual VOKERA THE LINEA RANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VOKERA THE LINEA RANGE. We hope that this VOKERA THE LINEA RANGE user guide will be useful to you.

Lastmanuals help download the user guide VOKERA THE LINEA RANGE.


Mode d'emploi VOKERA THE LINEA RANGE
Download
Manual abstract: user guide VOKERA THE LINEA RANGE

Detailed instructions for use are in the User's Guide.

[. . . ] The Linea 24 q Linea 28 Range Installation & Servicing Instructions British Gas Service Listed G. C. 47 094 29 (Linea Plus) THESE INSTRUCTIONS TO BE RETAINED BY USER CONTENTS Section Subject Section 1 Introduction General Layout Page no 1 1 Section Subject Concluding Operations Instructing The User Page no 20 20 21 21 21 21 22 22 23 23 23 24 24 24 25 25 26 26 26 27 27 27 28 28 29 29 29 29 29 29 30 Section 7 Section 8 Section 2 Design Principles & Operating Principles Schematic Diagram Central Heating Mode Domestic Hot Water Mode Safety Devices Frost Thermosat Technical Data Dimensions & Contents Connection Sizes Installation Requirements Electrical Details Performance & Limitations Working Pressure (H/W & C/H) Flow Rates Central Heating Pump Duty General Requirements Related Documents Location of Appliance Gas Supply Flue System Air Supply Water Circulation (C/H) Pipework By-Pass System Design Filling Point Electrical Supply Showers Installation Delivery Unpacking Preparing For Mounting Mounting The Appliance Fitting The Flue (Horizontal) Fitting The Flue (Vertical) Fitting The Flue (Twin) Connecting Gas & Water Supplies Electrical connections Commissioning Gas Installation Initial Flushing of Pipework Initial Filling of System System Design Pressure Checking Electrical supply Lighting The Boiler Checking Burner Pressures Range Rating C/H Checking The Flue System Checking The Heating Thermistor Regulating The C/H System Final Flushing The C/H System Filling & Testing H/W System Final Checks For Operation 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 5 5 5 5 5 6 6 6 6 6 8 8 8 Section 9 9 9 9 9 10 10 11 12 15 15 17 17 17 17 17 17 17 18 19 19 19 19 19 19 20 Section 3 Section 4 Servicing Instructions General Recommended Routine Servicing Replacement Of Parts To Gain General Access To Remove: Room Sealed Chamber Front Cover Main Burner & Electrode Main Burner Injectors Main Heat Exchanger Fan DAPS Combustion Chamber Insulation Panel Ignition PCB Gas Control Valve Pump Domestic Flow Switch Diverter Valve Domestic Heat Exchanger Diverter Valve Main Expansion Vessel Safety Valve Pressure Switch Motorised Valve Printed Circuit Board Display Printed Circuit Board Safety Thermostat Thermistor Sensors Pressure Gauge Setting Gas Pressures Operational Checks & Wiring Sequence of Functions Diagnostic Error Codes Fault Finding Guides Section 5 32 32 33 34-43 Section 6 Section 10 Appendix 44 Internal Time Clock Installation 44 External Time Clock Installation 46 S & Y Plan Installations 47 Exploded Diagrams 48-52 Abling & Disabling Controls 53 Functional Flow Diagram 54 Illustrated Wiring Diagram 55 Preliminary Electrical System Checks 56 LPG Instructions 57-58 Linea 24 & 28 SECTION 1 INTRODUCTION These appliances are designed for use with a sealed heating system only and are not intended for use on an open vented system. The provision of stored domestic hot water is possible by the addition of an indirect cylinder with 'S' or 'Y' plan controls. An automatic range-rating facility is incorporated in the boiler for the central heating system in conjunction with the electronic burner modulation. [. . . ] Inform the user of the location of all drain cocks and air vents. Explain how to turn the appliance off for both short and long periods and advise on the precautions necessary to prevent damage should the appliance be inoperative when freezing conditions may occur. Show the user the filling loop position its function and how to repressurise the system using the filling/inlet valve. Advise the user that, for continued safe and efficient operation, the appliance must be serviced by a competent person at least once a year. 7. 2 6. 14 6. 14. 1 7. 3 7. 4 6. 14. 2 6. 14. 3 6. 15 Hinge up the control fascia and secure using the two screws. (fig. 26) Disconnect filling loop, fit filling loop cap. Leave filling loop in a safe and accessible place. Supplementary Instructions for Fitting & Removing Optional Time Clock and for Wiring to External Controls. Section 10 Appendices A and B at the rear of this manual provides full instruction for fitting and wiring the optional built-in time switches and for wiring to external controls. 7. 5 7. 6 Fig. 26 Case Screws Case screws (one either side) 20 Linea 24 & 28 SECTION 8 8. 1 SERVICING INSTRUCTIONS 6. Gain general access as described in 8. 4. Lightly clean with a soft brush and inspect for damage. If during initial inspection any combustion irregularity was suspected, remove injectors and clean or replace (see 8. 7). Place cloth below combustion chamber to catch debris. Clean heat exchanger using suitable brushes and rods if necessary. The insulating material is easily damaged. If any panels are damaged these should be replaced (see 8. 11). Replace all parts in reverse order but leave the controls fascia open and outer casing off. 11. Undertake a complete commissioning check as detailed in section 6. 12. Close up control fascia and refix front casing. 13. Clean off casing using soft cloth and dilute detergent. 14. Complete details of service undertaken in the boiler log book. NOTE: there is a flue gas analysis test point incorporated in the flue outlet. [. . . ] Switch on the electricity supply, the boiler will now light at the minimum setting. When low flame is established the pressure reading should be : 24 5. 1mbar (Plus or minus 0. 5mbar) 28 4. 3mbar (Plus or minus 0. 43mbar) If it is different adjustment should be made in accordance with the instructions in 8. 23. 11. 11 If the reading is incorrect it should be adjusted as follows: Identify the minimum adjustment potentiometer on the PCB (fig. With the boiler still in central heating mode and the burner at the minimum rate, using a small screwdriver turn the potentiometer clockwise to increase & anti-clockwise to decrease the gas pressure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VOKERA THE LINEA RANGE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VOKERA THE LINEA RANGE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag