User manual WAVECOM FASTRACK SUPREME

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WAVECOM FASTRACK SUPREME. We hope that this WAVECOM FASTRACK SUPREME user guide will be useful to you.

Lastmanuals help download the user guide WAVECOM FASTRACK SUPREME.


Mode d'emploi WAVECOM FASTRACK SUPREME
Download
Manual abstract: user guide WAVECOM FASTRACK SUPREME

Detailed instructions for use are in the User's Guide.

[. . . ] Fastrack Supreme User Guide WA_DEV_Fastrk_UGD_001 Plug and Play Wireless CPU® FASTRACK Supreme User Guide Reference: WA_DEV_Fastrk_UGD_001 Revision: 001e Date: 5 June, 2007 Supports Open AT® embedded ANSI C applications confidential © This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written agreement. Source du renvoi introuvable. -00 Page: 1 / 69 Erreur !Source du renvoi introuvable. Fastrack Supreme User Guide WA_DEV_Fastrk_UGD_001 Document History Revision 001 001a 001b 001c 001d 001e Date 9 February, 07 23 February, 2007 21 May, 07 1 Jun, 07 4 Jun, 07 5 Jun, 07 First Issue Update DC cable GPIO mapping, add AutoShutDown Add detail of IES, RTC and serial port autoshutdown Change to Quad Band Update label/packaging photo Comment List of revisions confidential © This document is the sole and exclusive property of WAVECOM. [. . . ] The FASTRACK Supreme echo function is disabled. To enable the FASTRACK Supreme echo function, enter the ATE1. When sending AT commands to the FASTRACK Supreme by using a communication software, it is recommended: · · to disable the "local echo" parameter of your communication software (such as HyperTerminal), to enable the FASTRACK Supreme echo function (ATE1 command). In a Machine To Machine communication with the FASTRACK Supreme, it is recommended to disable the FASTRACK Supreme echo function (ATE0 command) in order to avoid useless CPU processing. For further information on ATE0 and ATE1 commands, refer to "AT Commands Interface Guide" [6]. confidential © This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written agreement. Source du renvoi introuvable. -00 Page: 35 / 69 Erreur !Source du renvoi introuvable. FASTRACK Supreme User Guide Using the FASTRACK Supreme 5. 5 Verify the Received Signal Strength The FASTRACK Supreme establishes a call only if the received signal is sufficiently strong. To verify the received signal strength, do the following operations: · Using a communication software such as HyperTerminal, enter the AT command AT+CSQ. The response returned has the following format: +CSQ: <rssi>, <ber> with: · · · <rssi> = received signal strength indication, <ber> = channel bit error rate. Verify the <rssi> value returned using the Table 6 below. Table 6: Values of received signal strength Value of received signal strength indication (<rssi>) 0 - 10 11 - 31 32 - 98 99 Interpretation of the received signal strength Insufficient(*) Sufficient(*) Not defined No measure available (*) Based on general observations. For further information on AT commands, refer to "AT Commands Interface Guide" [6]. 5. 6 Check the Pin Code Status To check that the pin code has been entered, use a communication software such as a HyperTerminal, then enter AT+CPIN?The table below gives the main responses returned: Table 7: AT+CPIN Responses AT+CPIN response (*) Interpretation Code PIN has been entered Code PIN has not been entered +CPIN: READY +CPIN: SIM PIN (*)For further information on the other possible responses and their meaning, refer to "AT Commands Interface Guide" [6]. 5. 7 Switch between EU/US Band(s) To switch between EU/US band(s) for the FASTRACK Supreme, use a communication software such as a HyperTerminal, then enter AT+WMBS=<band>[, <param>] command. The table below gives the commands for various band(s) selection: confidential © This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without prior written agreement. Source du renvoi introuvable. -00 Page: 36 / 69 Erreur !Source du renvoi introuvable. FASTRACK Supreme User Guide Using the FASTRACK Supreme Table 8: AT+WMBS Band Selection AT+WMBS response (*) Interpretation Select mono band mode 850MHz. Select mono band mode extended 900MHz Select mono band mode 1800MHz Select mono band mode 1900MHz Select dual band mode 850/1900MHz Select dual band mode extended 900MHz/1800MHz Select dual band mode extended 900MHz/1900MHz AT+WMBS=0, x AT+WMBS=1, x AT+WMBS=2, x AT+WMBS=3, x AT+WMBS=4, x AT+WMBS=5, x AT+WMBS=6, x (*)For further information on the other possible responses and their meaning, refer to "AT Commands Interface Guide" [6]. Remark: x=0 : The Plug & Play will have to be reset to start on specified band(s). x=1 : The change is effective immediately. This mode is forbidden while in communication and during Plug & Play initialization. Refer to "AT Commands Interface Guide" [6] for further information on AT commands. 5. 8 Check the Band(s) Selection To check the band selection for the FASTRACK Supreme, use a communication software such as a HyperTerminal, then enter AT+WMBS?The table below gives the main responses returned: Table 9: AT+WMBS Responses AT+WMBS response (*) Interpretation Mono band mode 850MHz is selected Mono band mode extended 900MHz is selected Mono band mode 1800MHz is selected Mono band mode 1900MHz is selected Dual band mode 850/1900MHz are selected Dual band mode extended 900MHz/1800MHz are selected Dual band mode extended 900MHz/1900MHz are selected +WMBS: 0, x +WMBS: 1, x +WMBS: 2, x +WMBS: 3, x +WMBS: 4, x +WMBS: 5, x +WMBS: 6, x (*)For further information on the other possible responses and their meaning, refer to "AT Commands Interface Guide" [6]. 5. 9 Verify the FASTRACK Supreme Network Registration 1. Make sure a valid SIM card has been previously inserted and locked in the FASTRACK Supreme SIM card holder. confidential © Page: 37 / 69 This document is the sole and exclusive property of WAVECOM. [. . . ] Do not expose the FASTRACK Supreme Plug & Play to any extreme environment where the temperature or humidity is high. Do not use or store the FASTRACK Supreme Plug & Play in dusty or dirty areas. Its moving parts (SIM holder for example) can be damaged. Do not attempt to disassemble the Wireless CPU®. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WAVECOM FASTRACK SUPREME

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WAVECOM FASTRACK SUPREME will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag