User manual WHARTON 4860

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHARTON 4860. We hope that this WHARTON 4860 user guide will be useful to you.

Lastmanuals help download the user guide WHARTON 4860.


Mode d'emploi WHARTON 4860
Download
Manual abstract: user guide WHARTON 4860

Detailed instructions for use are in the User's Guide.

[. . . ] Wharton 4850 / 4860 Master Clock Operating and Installation Instructions Issue 2. 0 4850 / 4860 Master Clock Operating and Installation Instructions © 1999-2006 Wharton Electronics Ltd, All rights reserved. In the interests of improving design, operational function, and/ or reliability, Wharton Electronics Ltd reserves the right to make changes to the products described in this document without notice. Trademarks Wharton Electronics, 4850, 4860, 4860net, net482, 400A and w482 are trademarks of Wharton Electronics Ltd. Mobaline is a registered trademark of Moser Baer AG. [. . . ] Press `^' to select. w482 Zone Setting Mode, zone 2 selected with current location flashing. Use `+' and `-' to change. w482 zone settings 4 - F Note: If you using the IRIG output (4861 and 4850. x. I versions only) or EBU output (4862 and 4850. x. E versions only) and are using it in an application that requires the location setting to be set to a time zone other than the local time zone, w482 zone 2 should be programmed for the local time zone and the slave displays should be configured accordingly. Zone F selected, press `+' and `-' to change current setting, `^' to return to normal time display. Normal time display. Issue 2. 0 6-1 Link RS232/RS485 S3 Data RS232/RS485 S4 10Base-T Net Update RS232/RS485 S2 - + A B A B no nc C IRIG-B GPS Receiver w482 Relay RS232/RS485 S1 MAC Address w482 time code system interconnection xx xx xx xx xx xx Operating and Installation Instructions 4850 / 4860 Master Clock 6-2 Issue 2. 0 4850 / 4860 Master Clock Operating and Installation Instructions 7 - RS232 & RS422/485 Serial Output 4850 / 4860 RS232 & RS485/422 Interface DB9-F Connector RS232 RS232/RS485 S1 Data Formats The serial messages numbered from 01 to 09 are user programmable. This allows the user to program information concerning the baud rate, data bits, parity, stop bits and serial repetition to ensure that the format chosen meets their requirements. Some of the other serial data messages have factory preset transmission formats to ensure that system interconnection is trouble free. Message Format Wharton Format 1 (Code 1) STX Su St Mu Mt Hu Ht Du Dt Mtu Mtt Yu Yt St ETX Wharton Format 2 (Code 4) T Yt Yu : Mtt Mtu : Dt Du : 0 W : Ht Hu : Mt Mu : St Su CR LF Byte S M H W D Mt Y STX ETX CR LF 0 : St Bit 0 Bit 1 Bit 2 Bit 3 Description seconds minutes hours day-of-week day-of-month month year start transmission end transmission carriage return line feed ASCII zero ASCII colon status - see table ASCII value 30h-39h 30h-39h 30h-39h 31h-37h 30h-39h 30h-39h 30h-39h 02h 03h 0dh 0ah 30h 3ah 30h-3fh 1 1PPS 2 Transmitted Data (TXD) 3 Received Data (RXD) 5 Signal Ground (GND) RS485/422 8 `A' - non-inverting 9 `B' - inverting Note: The 1PPS signal is at RS232 levels and goes high for 100ms on the second edge. Operation The 4850 / 4860 Master Clock is fitted as standard with one RS232 & RS485/RS422 serial data output. The signals are accessed via the female DB9 connector labelled RS232/RS485 S1 mounted on the rear of the unit. Additional serial outputs (4860. S2 & . S4 versions only) The 4860 is optionally available with two or four RS232/RS485 serial data outputs. Where installed, these signals are accessed via the S2, S3 and S4 female DB9 connectors. If your 4860 is fitted with multiple serial ports, extra serial setting modes (S2, S3 & S4) will appear in the main programming menu to allow these ports to be individually configured using the procedure detailed below. (Please note: The RS232 level 1 pulse per second output is not present on pin1 of serial ports S3 & S4). Setting the Message Format The 4850 / 4860 has 71 different preprogrammed serial output messages. The desired message can be selected from the lists on page 7-2 and programmed into the 4850 / 4860 using the procedure on page 7-5. Please also refer to Appendix C for details of products compatible with the 4850 / 4860. Setting the Output Message Time Offset The 4850 / 4860 serial output message may be referenced to the current location setting (see section 4) or UTC/GMT as detailed in the procedure on page 7-5 . Status byte - ASCII value 30h-3fh undefined. 0 = Winter time, 1 = Summer Time 0 = not synchronised, 1 = synchronised 0 = no early warning bit, 1 = early warning bit Application Notes The 4850 / 4860 Information CD contains application notes detailing the use of the 4850 / 4860 with many different types of equipment. If you are unable to access the CD or require further information on the setup and use of the serial output please contact our technical support representatives. The Serial Messages table on page 7. 2 contains references to application notes which contain additional information specific to that serial message. User programmable serial settings Display bAud Setting Baud Rate Range 19 - 19200 baud, 96 - 9600 baud, 48 - 4800 baud, 24 - 2400 baud, 12 - 1200 baud. odd - Odd parity, EvE - Even parity, no - No parity. 1SE - 1 serial message every sec, 1nn - 1 serial message every min, 5nn - 1 serial message every 5 min, 1 Hr - 1 serial message every hour, 24 Hr - 1 serial message every 24 hrs at Midnight, 4An - 1 serial message every 24 hrs at 4 AM, rSE - On demand, next second edge. P15 - 1 serial message at 15 mins past every hour. Notes Data transmission rate. bitS PAr StoP R ep Data bits Parity Stop bits Serial Repetition Number of data bits in each ASCII character. [. . . ] Subnet Mask The subnet mask when combined with the IP address identifes the subnet (part of the bigger network) that the 4860net is connected to. Gateway Address The gateway address is used by the 4860net when it needs to send information to computers and devices which are connected to other networks and subnets. NTP Server IP Address This is the Internet Protocol address of the NTP time server that the 4860netclient uses as a Time Source. 8) Sb Gt nt D-1 Issue 2. 0 4850 / 4860 Master Clock Operating and Installation Instructions Synchronisation Status Display When in normal time display mode the plus and minus buttons can be used to cycle through the date, synchronisation and temperature status displays, as detailed on page 2-5. However, when NTP is selected as the synchronisation source, the synchronisation status display operates as detailed below NTP Synchronisation status - please refer to the table below for further information. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHARTON 4860

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHARTON 4860 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag