If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL 8206327-D-WH. We hope that this WHIRLPOOL 8206327-D-WH user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL 8206327-D-WH.


Mode d'emploi WHIRLPOOL 8206327-D-WH
Download
Manual abstract: user guide WHIRLPOOL 8206327-D-WH

Detailed instructions for use are in the User's Guide.

[. . . ] ® Microwave Hood Combination OVERALL DIMENSIONS PRODUCT MODEL NUMBERS MH3184XP MH3185XP Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp electrical supply located in the upper cabinet as close as possible to the microwave oven hood. A time-delay fuse or circuit breaker and separate circuit is recommended. 17-1/8" (43. 5 cm) 15-7/8" (40. 3 cm) 15-3/8" (39. 1 cm) 29-7/8" (75. 9 cm) CABINET OPENING DIMENSIONS Space between cabinets must be 30" (76. 2 cm) minimum and be free of obstructions. [. . . ] To calculate the length of system you need, add the equivalent feet for each vent piece used in the system. 3-1/4" x 10" (9. 5 cm x 25. 4 cm) vent system 3-1/4" x 10" 90° elbow 6 ft. (1. 8 m) wall cap Recommended standard fittings 3-1/4" x 10" to 6" = 5 ft. 3-1/4" x 10" roof cap = 24 ft. 3-1/4" x 10" 90° elbow = 25 ft. 90° elbow 6" = 10 ft. 3-1/4" x 10" wall cap = 40 ft. 45° elbow 6" = 5 ft. 3-1/4" x 10" flat elbow = 10 ft. For wall or roof venting methods: If the wall exhaust method is chosen, be sure that there is proper clearance within the wall for the damper to fully open. Wall and roof caps must have back-draft damper. that length of vent and number of elbows should be kept to a minimum to provide efficient performance. using duct tape to seal all joints in the vent system. using caulking compound to seal exterior wall or roof opening around cap. two elbows should not be installed together. We do NOT recommend: flexible metal vent. NOTE: If flexible metal vent must be used, calculate each foot of flexible metal vent as two feet of rigid metal vent. Flexible metal elbows count twice as much as standard elbows. 2 ft. (0. 6 m) 1 - 3-1/4" x 10" 90° elbow 1 - wall cap 8 feet straight Length of 3-1/4" x 10" system = 25 ft. [. . . ] For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL 8206327-D-WH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL 8206327-D-WH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag