User manual WHIRLPOOL AGB 374/WP INSTRUCTION FOR USE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AGB 374/WP. We hope that this WHIRLPOOL AGB 374/WP user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AGB 374/WP.


Mode d'emploi WHIRLPOOL AGB 374/WP
Download
Manual abstract: user guide WHIRLPOOL AGB 374/WPINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] 032_03 02/2006 Instructions for installation, use and maintenance GAS KETTLES AGB AGB AGB AGB AGB AGB AGB AGB AGB AGB AGB AGB 373/WP · AGB 378/WP 387/WP · AGB 393/WP 388/WP 379/WP 391/WP 371/WP · AGB 374/WP 383/WP · AGB 389/WP 376/WP · AGB 385/WP 395/WP 398/WP 397/WP 402/WP · AGB 403/WP INDEX Models and dimensions Size of appliance and position of connections Measuring the inlet pressure Gas cock Pilot burner Main burner Primary air regulation Controls Relief valve (only pressure kettles) General reminders and notes General reminders Technical data Construction Special features for pressure kettles Special features for indirect kettles Laws, technical prescriptions and directives 10 Special requirements for the installation site10 Positioning, installation and maintenance Positioning Installation 11 11 Warning 16 5 5 5 5 5 6 6 6 7 7 Use and cleaning 8-9 10 10 10 Warnings and hints for user Instructions for use Filling the jacket (Models indirect) Use of pressure kettle lid Switch on, start of cooking and switch off Cleaning and care of the appliance Daily cleaning Special procedures in case of long inactivity Special procedures in case of failures How to proceed, if … 15 15 15 14 14 14 14 14 15 15 pag. 3 Connection to waterworks Gas connection procedures Control of the gas inlet pressure Control of primary air flow Commissioning and testing Conversion to other types of gas Replacement of injectors for pilot burner Minimum output adjustment Maintenance of the appliance Possible failures and their elimination 11 11 12 12 12 12 12 12 13 13 Checking the operation of the gas system 11 Replacement of injectors for main burners 12 032- 03 - Gas kettles 2 Dimensions AGB 373/WP - AGB 378/WP AGB 371/WP - AGB 374/WP AGB 379/WP - AGB 376/WP AGB 387/WP - AGB 393/WP AGB 388/WP - AGB 391/WP AGB 383/WP - AGB 389/WP AGB 385/WP ABGST- Hot water connection 10 mm Cold water connection 10 mm Gas connection R 1/2” in conformity with ISO 7-1 Overflow Technical data plate ABGT- Hot water connection 10 mm Cold water connection 10 mm Gas connection R 1/2” in conformity with ISO 7-1 Technical data plate 032- 03 - Gas kettles 3 Dimensions AGB 395/WP AGB 398/WP AGB 397/WP AGB 402/WP - AGB 403/WP A TAGB- Technical data plate Hot water connection 10 mm Gas connection R 1/2” in conformity with ISO 7-1 Cold water connection 10 mm 032- 03 - Gas kettles 4 Measuring the inlet pressure Gas cock A B Inlet pressure intake Outlet pressure intake A B C D E F G H Thermocouple nut Gas output Outlet pressure intake Inlet pressure intake Rated output adjustment screw Gas inlet Gas connection for pilot burner Minimum output adjustment screw Pilot burner Main burner B A C B C A D A B C D E Thermocouple Pilot burner Ignition plug Injector Tightness screw E A B C Burner Injector Injector pipe 032- 03 - Gas kettles 5 Primary air regulation Controls Relief valve (only pressure kettles) Manual vapour vent F C E A D A C D E F Knob OFF position Minimum position Maximum position Pilot flame position 032- 03 - Gas kettles 6 GENERAL REMINDERS AND NOTES - Read the warnings contained in this manual carefully as they provide important information concerning safety during the installation, use and maintenance of the appliance. - Only personnel trained for its specific use should use the equipment. - Keep the appliance under control during use. - The appliance should be used only for the purpose for which it has been specifically designed; other uses are improper and hence dangerous. [. . . ] - Re-install the primary air regulation bracket at the distance “H” as shown in table page 9, see also “Primary air regulation”. CONTROL OF PRIMARY AIR FLOW - Primary air can be considered correctly adjusted if no flame lift is ensured when the burner is cold and the injector lights when the burner is hot. - The distance “H” (see figure “Primary air regulation”) recommended for primary air adjustment is stated in table page 9 in the “Technical data”. REPLACEMENT OF INJECTORS FOR PILOT BURNER - The injector of the pilot burner can be reached by removing the lower front panel. - The pilot burner is in the front of the combustion chamber. - Unloose the screw and replace the injector with an appropriate one. COMMISSIONING AND TESTING - Once all the connections have been made, the appliance and the overall installation must be checked following the directions given in this manual. - Check in particular: - that the protective film has been removed from the external surfaces; - that connections have been made in accordance with the requirements and directions indicated in this manual; - that all safety requirements in current standards, statutory regulations and directives have been met; - that the water and gas connections are leak-free; - that the electrical connection has been performed according to standards. - Now the appliance can be ignited following the instructions for use and controlling the following points: - progressive ignition of the burner; - even flames; - flame security: check these points at both minimum and maximum output. - Check that the flue gas exhaust is not clogged and that they are expelled without any hindrance. - The test report must be completed in full and submitted to the customer who should then sign in acceptance. With effect from this moment, the appliance is covered by the manufacturer’s warranty. MINIMUM OUTPUT ADJUSTMENT - Once the appliance has been switched on, set the cock knob on the minimum position. - Remove the cock knob that will reveal a small hole on the panel of the appliance. - Turn the minimum adjustment screw on the cock with a screwdriver through the hole on the panel. Warning!: Measure the minimum output pressure directly at the output pressure connection on the injector tube (see figure “Measuring gas pressure”) - Set the output pressure of the gas cock according to the figures stated in table page 9 - Minimum output setting). - After setting, seal the adjustment screw!Warning!: After each conversion, it is necessary to check tightness and operation! 032- 03 - Gas kettles 12 MAINTENANCE OF THE APPLIANCE Warning!: All maintenance operations shall only be performed by a technically qualified service centre!- To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year only. Maintenance includes also to control the components and tear of pipes, feeding pipes etc. . It is advisable to replace worn components during maintenance operations to avoid the need for other maintenance calls and unexpected failures. - It is also advisable to apply for a maintenance contract with the customer. POSSIBLE FAILURES AND THEIR ELIMINATION Warning!: Only technically qualified service centres can perform the operations described below!Warning!: Before resetting the safety thermostat, it is always necessary to eliminate the problem causing its activation (only for models with indirect heating)! Problem and possible cause Access to components and operation The content of the vat does not heat up: - the safety thermostat has been activated. The pilot burner is on but the main burners do not light up: - loss of pressure in gas supply; - clogged injectors on main burners. The pilot burner does not light up: - clogged injectors on pilot burner; - faulty ignition plug; - check the cable of the ignition plug. The pilot burner does not remain lighted: - faulty thermocouple; - partially clogged injector on pilot burner; faulty cock magnet. [. . . ] For the same reason avoid contact with materials containing iron. - Do not use sandpaper or abrasive paper for cleaning; in special cases use a powder pumice stone. - In case of particularly resistant dirt, it is advisable to use abrasive sponges (e. g. - It is advisable to clean the appliance only once it has cooled down. SPECIAL PROCEDURES IN CASE OF FAILURES - If the appliance should not work properly during use, turn it off immediately and close or cut off all supplies (gas and water). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AGB 374/WP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AGB 374/WP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag