User manual WHIRLPOOL AKS 213/IX INSTRUCTION FOR USE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKS 213/IX. We hope that this WHIRLPOOL AKS 213/IX user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AKS 213/IX.


Mode d'emploi WHIRLPOOL AKS 213/IX
Download
Manual abstract: user guide WHIRLPOOL AKS 213/IXINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] GB IMPORTANT SAFETY INSTRUCTIONS BUILT-IN GAS HOB INSTRUCTIONS In case of prolonged use, additional ventilation may be necessary (by opening a window or increasing the hood extraction speed). After use, make sure the knobs are in off position and close the main gas supply cock or the gas cylinder valve. Overheated oils and fats catch fire easily. Always remain vigilant when cooking foods rich in fat, oil or alcohol (e. g. [. . . ] Light up the burners and turn the knobs from max position position to check flame stability. to minimum (Apply the label from warranty here) 5019 619 01698 Manufacturer: Whirlpool Europe S. r. l. Borghi, 27 21025 Comerio (VA) ITALY ELECTRICAL CONNECTION WARNING WARNING This operation must be performed by a qualified technician. • • • The electrical connections must comply with local regulations. The earthing of this appliance is compulsory by law. L Earth (yellow/green) N REPLACING THE INJECTORS (see the injector table in the Instruction) • • • Remove grids (A). Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to be replaced. • Replace it with the injector suitable for the new type of gas. • If you have a multiple crown burner use side spanner to replace the injector (E). Before installing the hob, remember to affix the gas calibration plate supplied with the injectors in such a way that it covers the existing information relating to gas calibration. IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate. ASSEMBLY After having cleaned the perimeter surface, apply the supplied gasket to the hob as shown in the figure. ADJUSTING MINIMUM GAS SETTING OF TAPS To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows: • tighten screw to reduce the flame height (-); • loosen screw to increase the flame height (+). The adjustment must be performed with the tap in minimum gas setting position (small flame) . • The primary air of the burners does not need to be adjusted. • At this stage, light up the burners and turn the knobs from max position to Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction. NOTE: the power supply cable must be long enough to permit its upward extraction. To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance with the thickness of the worktop (see the following figures). Top 30-50 mm minimum position to check flame stability. Upon completion of adjustment, reseal using sealing wax or an equivalent material. Top 20 mm REFERENCE TO LOCAL REGULATIONS Regulation for room ventilation Note: If the appliance is not equipped with safety devices on the burners (thermocouples), the air vents must be increased by 100%, and must be at least 200 cm2), in compliance with M. D. 21 April 1993. Connection to gas supply Before connecting the appliance, make sure that the gas supply system complies with standards UNI-CIG 7129 and UNI CIG 7131. ADJUSTMENT TO DIFFERENT TYPES OF GAS WARNING This operation must be performed by a qualified technician. Gas connection The connection to the mains gas network or gas cylinder must be made using a rigid copper or steel pipe with fittings complying with standards UNI-CIG 7129, or using a continuous-surface stainless steel hose complying with standards UNI-CIG 9891. The pressure control valves to be used must comply with the UNI EN 12864 standard for gas cylinders and the UNI EN 88 standard for piped methane gas. If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors. Remove the information label and keep it with the instructions booklet. [. . . ] Control knobs The symbols are indicating which cooking field this knob activates. Note: your hob aesthetics can be slightly different from the drawing. PRATICAL ADVICE FOR USING THE BURNERS This hob has burners of different diameters. For better burner performance, please stick to the following rules: - Use pots and pans with bottoms the same width as that of the burners or slightly larger (see table on the right). - Use the correct amount of water for cooking foods and keep the pot covered. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKS 213/IX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AKS 213/IX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag