User manual WHIRLPOOL WRF540CWBW WARRANTY INFORMATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL WRF540CWBW. We hope that this WHIRLPOOL WRF540CWBW user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL WRF540CWBW.


Mode d'emploi WHIRLPOOL WRF540CWBW
Download

You may also download the following manuals related to this product:

   WHIRLPOOL WRF540CWBW ENERGY GUIDE (118 ko)
   WHIRLPOOL WRF540CWBW DIMENSION GUIDE (156 ko)
   WHIRLPOOL WRF540CWBW USE & CARE GUIDE (1539 ko)

Manual abstract: user guide WHIRLPOOL WRF540CWBWWARRANTY INFORMATION

Detailed instructions for use are in the User's Guide.

[. . . ] 8 Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Component Description . 20 Removal and Replacement Reservoir and Bin Controls . 31 Parts lists and wiring diagrams are in the center of this manual, printed on yellow paper. December, 1988 Page 1 WRF540CWBW FOR THE INSTALLER BACK VIEW: AIR COOLED Note: Allow 6" behind and 6" above either unit for air circulation, utility connections, and service. ELECTRICAL INLET BACK VIEW: WATER COOLED ELECTRICAL INLET WATER INLET 9. 5" 5. 25" 3" 5. 25" 3" 7. 3" 9. 43" WATER INLET 3/8" FLARE DRAIN 3/4" FPT Condenser Inlet 3/8" FPT 2. 1" 5. 7" 2. 9" Condenser Drain 1/2" FPT 3. 4" DRAIN 3/4" FPT 4. 9" 7. 46" The WRF540CWBW is designed to fit the following Scotsman storage bins: B590 and extensions (with bin top KBT18) BH800 using bin top KBT15 (one unit). [. . . ] Disconnect electrical power, and remove the filter. Clean the condenser: the condenser may appear to be clean on the surface, but it can still be clogged internally. Check with a flash light from the front to see if light can be seen though the condenser fins. Step 2: Remove shroud cover. Step 1: Remove top panel. Step 3: Clean the condenser. December, 1988 Page 18 WRF540CWBW MAINTENANCE AND CLEANING: Auger In some areas, the water supply to the ice maker will contain a high concentration of minerals, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected. Note: Water filters can filter out suspended solids, but not dissolved solids. "Soft" water may not be the complete answer. Check with a water treatment specialist regarding water treatment. For more information on removal of these parts, see REMOVAL AND REPLACEMENT. //////////////////////////////WARNING//////////////////////////// Switch off electrical power, and turn off the water supply. If the unit trips out on pressures below 450 psig, replace the control. If the pressures rise above the trip out point, and the unit shuts down: a. Check for adequate water flow on water cooled, if adequate, clean the interior of the condenser. If the pressures are still too high replace the water regulating valve. Check for adequate air flow on air cooled. Clean the condenser and (if used) the filter. If the air flow is poor because of the installation, advise the user that the unit should be moved, or the air around it kept cooler. Check the fan motor for tight bearings and proper rotation. Check that the fan blades are clean, and the fan secure to the fan motor shaft. It opens from excess pressure of ice inside the ice chute: this should only happen when the machine does not shut off when the ice storage bin is full. This switch will reset when the ice melts, but the machine will not resart until the reset switch on the circuit board is pressed. [. . . ] If there is evidence of water in the oil (rusty bearings and gears; the oil having a creamy white appearance; oil level too high) carefully inspect the bearings and gears. If in doubt about the condition of a part, replace it. The oil quantity is 14 fluid ounces, do not overfill. Note: The gears and bearings are available only as pressed together sets. WATER SHED CENTRIFUGAL SWITCH SEAL AUGER DRIVE MOTOR ROTOR BEARING SEAL D) After replacing parts as required, (if any) reassemble the gearcase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRF540CWBW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRF540CWBW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag