User manual WHISTLER PP200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHISTLER PP200. We hope that this WHISTLER PP200 user guide will be useful to you.

Lastmanuals help download the user guide WHISTLER PP200.


Mode d'emploi WHISTLER PP200
Download
Manual abstract: user guide WHISTLER PP200

Detailed instructions for use are in the User's Guide.

[. . . ] 200/400 Watt Series 3/6/02 3:05 PM Page 1 OWNER'S MANUAL 200/400 WATT SERIES THE WHISTLER GROUP CORPORATE HEADQUARTERS 13016 N. Bentonville, AR 72712 TEL (479) 273-6012 FX (479) 273-2927 www. whistlergroup. com PRODUCT DEVELOPMENT CENTER 25 Industrial Ave. Chelmsford, MA 01824 TEL (978) 244-1400 FX (978) 244-1491 CUSTOMER RETURN CENTER 1201 N. Rogers, AR 72756 Consumer Relations Tel (800) 531-0004 Email: info@whistlergroup. com P/N 400WATTMAN ©WHISTLER 2002 HIGH SURGE POWER INVERTERS 200/400 Watt Series 3/6/02 3:05 PM Page 3 INTRODUCTION If you have questions concerning the operation of this Whistler product please call consumer relations: Dear Whistler Owner, For many of us, a vehicle is more than just transportation. [. . . ] Although it is not necessary to disconnect the inverter when turning over the engine, the inverter may momentarily cease operation as the battery voltage decreases. When the inverter is not supplying power, and turned on, it draws very low amperage from the battery (<0. 40 A ). ADDITIONAL FEATURES Automatic Shut Down & Related Safety Features. Each inverter has an unique LED indicator warning light system which operates in conjunction with the automatic shut down feature. These indicator lights operate as follows: GREEN LED: YELLOW LED: System ready. System overload/automatic shut down. Your inverter will shut down automatically when any of the following problems occur: 1. The power input from the battery drops below 9. 5 volts. The power input from the battery exceeds 16 volts. The continuous draw of the appliance or equipment being operated exceeds the design parameters of the inverter. The inverters are also equipped with the following additional safety features: 1. Thermal Cut Off: Automatic shut down when the internal circuit temperature exceeds standard design parameters for safe operation. 12 13 200/400 Watt Series 3/6/02 3:05 PM Page 17 ADDITIONAL FEATURES 2. Low Battery Voltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power source drops below 10. 5 volts, an audible tone will be heard. b) The inverter will automatically shut down when the input voltage drops below 9. 5 volts. This protects the battery from completely draining. In the event of automatic shut down or continuous audible alarm, turn the inverter rocker switch to the OFF (O) position until the source of the related problem has been identified and resolved. Wall Mounting: Whistler inverters have provisions for wall mounting; two slotted holes in the handle area and a notched area at the power cord end allow for easy wall mounting of the unit. Your WHISTLER GO AC inverter will work best when placed on a reasonably flat surface. The floor or seat of your car or truck both are good locations. When driving with the inverter in operation, make certain that neither the inverter nor the power cords will impede safe operation of your vehicle. Keep the unit and all cords clear of the steering wheel, gas, brake and clutch pedals and gear shift. · CARE AND MAINTENANCE To maintain your inverter in proper working condition, note the following important safety precautions: · MOISTURE. Do not operate the inverter if you, the inverter, the device being operated or any other surfaces that may come in contact with any power sources are wet. Water and many other liquids can conduct electricity which may lead to serious injury or death. For peak efficiency, the ambient air temperature should be between 50° and 80° F. [. . . ] Units returned without a dated store receipt will be handled as described in section "Service Out Of Warranty. " When returning a unit for service under warranty, please follow these instructions: 1. Ship the unit in the original carton or in a suitable sturdy equivalent, fully insured, with return receipt requested, and shipping charges prepaid to: Whistler Repair Dept. 72756 WARRANTY IMPORTANT: Whistler will not assume responsibility for loss or damage incurred in shipping. Therefore, please ship your unit insured with return receipt requested. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHISTLER PP200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHISTLER PP200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag