User manual XTA REMOTE INTERFACES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual XTA REMOTE INTERFACES. We hope that this XTA REMOTE INTERFACES user guide will be useful to you.

Lastmanuals help download the user guide XTA REMOTE INTERFACES.


Mode d'emploi XTA REMOTE INTERFACES
Download
Manual abstract: user guide XTA REMOTE INTERFACES

Detailed instructions for use are in the User's Guide.

[. . . ] A null modem cable will NOT work, as the "transmit" and "receive" connections are swapped. · Units may be cascaded from this first one, using the RS485 ports on the rear of the unit and standard XLR mic leads. This type of cable is generally available in most computer hardware stores, but do be sure to get a one to one cable as explained above. Alternatively, it can be purchased from your local XTA supplier or directly from XTA by credit card. [. . . ] XTA Part Number: USB-232 For technical support on this product please email tech@xta. co. uk. Interface Options Page 5 USB-485 ­ USB to RS485 Conversion Kit What is it?A combination of a USB to serial interface and RS232 to RS485 converter to provide direct balanced 2 wire + shield connection. 1 x Aten "UC232a" USB- Serial adapter with driver disk & manual; 1 x KK Systems "K2-ADE" RS232-RS485 converter; 1 x 9 pin D-type male to 3 pin XLR male adapter cable. When the (first) unit to be controlled is more than 25 feet from the PC/laptop AND the computer doesn't have a standard 9-pin COM port (but does have a spare USB port!). · The KK systems "K2-ADE" RS232-RS485 interface supplied in this kit is NOT the same as the one in the standard 232-485 kit ­ note the "ADE" suffix which stands for Automatic Device Enable. The non-ADE version will not work reliably!· The "K2-ADE" converter has a set of DIP switches to adapt the system for various uses. These are set correctly by XTA when leaving the factory and should not be adjusted. If for any reason they are different, the correct settings are shown in the diagram to the left. · The wiring for the 9 pin D-type to 3 pin XLR is as follows: D-type XLR 1 1 3 2 8 3 Maximum cable length from the output of the converter is 1000 metres. · Where do I get one?There is a multitude of very similar looking USB to serial devices available in most computer stores but in our experience, they can prove unreliable due to timing of data through the converter, and inconsistencies between manufacturers. It is highly recommended that the XTA converter be used!Similarly, many RS232 to RS485 converters are available through specialist suppliers, but the KK systems converter has been proven by XTA to work reliably in all cases and we recommend you use this device. The kit can be purchased from your local XTA supplier or directly from XTA by credit card. See the end of this document for details. XTA Part Number: USB-485 For technical support on this product please email tech@xta. co. uk. Interface Options Page 6 INT-WLAN ­ Walkabout Kit : WiFi Conversion Kit What is it?A combination of a WLAN to serial interface and a high power wireless PCMCIA card to provide a remote connection using standard WiFi/WLAN 802. 11b technology. 1 x OTC Wiser 2400 WLAN / WiFi to serial converter; Serial cables to connect Wiser to unit or PC for programming; Power supply for Wiser; Netgear WG511T WLAN Card; All required setup software and manuals supplied on custom CD. If it is impossible to get a wired connection to the unit(s) for remote control or there is a requirement to be able to move around a venue whilst controlling the unit(s). This provides a cost-effective solution. Only one kit is required per system, as the Wiser WiFi to serial converter connects to the standard RS232 port on the first unit in the system. All other units are cascaded via the RS485 as with a normal wired connection. [. . . ] · If a unit is at FOH or close to the computer, if can be used to perform the RS232 to RS485 conversion for you. The RS485 port from this local unit can then be used to connect to the other units that are not nearby. · If a Wiser wireless link is being used and it sometimes makes more sense for the receiver to be placed at FOH or somewhere other than the remote units location due to signal strength / line of sight problems. Purchasing any of these interfaces. . . All of the interfaces can be ordered through your local distributor. If you're not sure who that is, go to http://www. xta. uk. com/distributors. htm to find the one nearest you. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE XTA REMOTE INTERFACES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual XTA REMOTE INTERFACES will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag