User manual XTANT X603

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual XTANT X603. We hope that this XTANT X603 user guide will be useful to you.

Lastmanuals help download the user guide XTANT X603.


Mode d'emploi XTANT X603
Download

You may also download the following manuals related to this product:

   XTANT X603 INSTALLATION (165 ko)

Manual abstract: user guide XTANT X603

Detailed instructions for use are in the User's Guide.

[. . . ] T h e L o w p a s s f u n c t i o n o f t h e c r o s s o v e r i s d e d icated to the amplifier (1001dx) and the Hipass function of the crossover is available at the on-board RCA line outputs. The jumper labeled Lowpass Slope Select allows either 12 or 24 dB per octaves slopes to be selected for the Lowpass function of the 1001dx. The Line Out Mode Select jumper controls the function of the on-board RCA line outputs and offers two (2) modes of operation: Bypass and HiPass. [. . . ] The Hipass Slope Select jumper provides independent 12 or 24 dB per octave slope selection for the Hipass function available at the RCA Line Outputs. The High and Low Pass frequenies are determined by the Frequency Modules (SIPs) installed in the three (3) SIP sockets pictured on the reverse side of this document. One SIP determines the Lowpass frequency, while two (2) SIPs determine the Hipass frequency. Each frequency setting is independent and may be changed to suit your needs. The following is a chart of Xtant's available frequency modules. The frequency module (SIP) "ID Code" printed on the SIP and the associated frequency value is detailed below. SIP Number 2 1 1 1 6 5 2 1 1 7 2 1 1 2 3 1 0 8 6 7 5 0 5 4 8 5 4 4 4 4 3 3 3 3 3 2 2 2 2 Frequency 5 7 8 9 2 5 0 0 0 1 3 4 5 0 0 0 0 0 0 0 0 0 k k k k H H H H H H H H H H H H H z z z z z z z z z z z z z INPUT SENSITIVITY ADJUSTMENT INSTALLER DA T E INSTALLED: N A M E: ' S REFERENCE LOG xtant technologies installer's reference OWNERS PHONE: TH I S A D D R E S S: CITY/ ST A T E: V E H I C L E: XT A N T A M P L I F I E R: M O D E L CROSSOVER MODES OF OPERATION ZI P: YE A R: S E R I A L# DOCUMENT H A S B E E N C R A F T E D T O M A K E I N S T A L L AT I O N, SYSTEM D E S I G N A N D TROUBLE- SHOOTING, A Q U I C K A N D E A S Y PROCESS. TH E C H A R T S P R O V I D E D, O F F E R A S I MP L E METHOD O F D O C U M E N T A T I O N. CROSSOVER SETTINGS: LOWPASS FREQ: VALUE CODE: JUMPER SETTINGS: SLOPE: IT IS IMPORTANT THAT YOU RETAIN THIS LOG FOR YOUR RECORDS. xtant technologies · · · · · · · · · · SERIAL · · · · · · · · Remove protective covering from amplifier and clean per the maintanence section on page 9 of the O w n e r ' s M a n u a l . Attach cover to base. · · · · · · · · · 7 6 7 6 SOUTH 4 6T H STREET. PHOENIX, ARIZONA 8 5 0 4 0 U S A · · · · · · · · 602. 431. 8686 INSTALLER'S . REFERENCE. . . . . . . . . . . . . INPUT SENSITIVITY: TO ADJUST INPUT GAIN, MOVE JUMPER (IF NEEDED) ­ AND INSTALL IT IN THE LOCATION WHICH MATCHES YOUR INPUT SIGNAL LEVEL. REFER TO THE ILLUSTRATION BELOW FOR PROPER JUMPER LOCATION / LEVEL SETTING. NOTE: ­20 dB = 10V ­ 17V IS ONLY TO BE USED WITH BALANCED INPUT FROM A BALANCED SOURCE. FAN ­20 dB = 10V­17V ­10 dB = 3V ­ 8V 0 dB = 1V ­ 3V +10 dB = 300mV­1V +20dB=100­300mV AMPLIFIER GAIN CONTROL: TURN CLOCKWISE TO INCREASE GAIN LOW PASS FREQ SIP YOU TO INVERT THE PHASE BY 180º AT THE OUTPUT OF THE 1001dX. THIS JUMPER DOES NOT AFFECT THE PHASE OF THE RCA LINE OUTPUTS. AMP PHASE SELECT: THE AMP PHASE SELECT JUMPER ALLOWS EQ MODULE PORT: REMOVE JUMPERS PRIOR TO INSTALLING EITHER THE OPTIONAL PQM-1 OR LFQ 45 MODULE. JUMPERS MUST BE IN PLACE IF AN EQ MODULE IS NOT INSTALLED. AMP PHASE SELECT INVERT NORMAL LINE OUT MODE SELECT BYPASS LP SLOPE SELECT 12 dB/OCT. [. . . ] JUMPERS MUST BE IN PLACE IF AN EQ MODULE IS NOT INSTALLED. AMP PHASE SELECT INVERT NORMAL LINE OUT MODE SELECT BYPASS LP SLOPE SELECT 12 dB/OCT. 24 dB/OCT. HP SLOPE SELECT RED LED POWER ON BLUE LED LOW VOLTAGE YELLOW LED LOW IMPEDANCE 12 dB/OCT. 24 dB/OCT. HIGH PASS FREQ SIP BALANCEDLINEPORT: HIPASS ­20 0 +10 +20 RIGHT CHANNEL ­10 HIGH PASS FREQ SIP LEFT CHANNEL JUMPERS MUST BE IN PLACE WHEN OPTIONAL BLM-1 MODULE IS NOT INSTALLED. SERVICE JUMPER: REMOVING JUMPER WILL TURN-OFF AMPLIFIER WHEN REMOTE TURN-ON, GROUND AND +12 VOLT CABLES ARE CONNECTED TO AMPLIFIER. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE XTANT X603

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual XTANT X603 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag