User manual YAESU FT-950

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YAESU FT-950. We hope that this YAESU FT-950 user guide will be useful to you.

Lastmanuals help download the user guide YAESU FT-950.


Mode d'emploi YAESU FT-950
Download

You may also download the following manuals related to this product:

   YAESU FT-950 BROCHURE (5762 ko)
   YAESU FT-950 MENU MODE (400 ko)
   YAESU FT-950 MENU MODE LIST (399 ko)
   YAESU FT-950 OPERATING MANUAL (6432 ko)
   YAESU FT-950 UPDATE V0112 AND V11.53 (144 ko)
   YAESU FT-950 UPDATE V0112 AND V11.54 (142 ko)
   YAESU FT-950 UPDATE V0115 AND V11.54 (137 ko)
   YAESU FT-950 INSTALLATION INSTRUCTIONS (7059 ko)
   YAESU FT-950 CAT OPERATION REFERENCE BOOK (729 ko)
   YAESU FT-950 CAT OPERATION REFERENCE BOOK (729 ko)
   YAESU FT-950 UPDATE V0113 AND V11.54 INFORMATION (136 ko)
   YAESU FT-950 UPDATE V0114 AND V11.54 INFORMATION (137 ko)

Manual abstract: user guide YAESU FT-950

Detailed instructions for use are in the User's Guide.

[. . . ] HF/50 MHZ TRANSCEIVER FT-950 OPERATING MANUAL VERTEX STANDARD CO. , LTD. VERTEX STANDARD 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan US Headquarters 10900 Walker Street, Cypress, CA 90630, U. S. A. YAESU EUROPE B. V. Box 75525, 1118 ZN Schiphol, The Netherlands Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U. K. VERTEX STANDARD HK LTD. Unit 5, 20/F. , Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong VERTEX STANDARD (AUSTRALIA) PTY. , LTD. Normanby Business Park, Unit 14/45 Normanby Road Notting Hill 3168, Victoria, Australia ABOUT THIS MANUAL . . The FT-950 is a leading-edge transceiver with a number of new and exciting features, some of which may be unfamiliar to you. [. . . ] Press the [ PROC ] button repeatedly until the " " and " " icons appear in the display, confirming that the Speech Processor is engaged. ADVICE: Blinking " " and " " icons indicate the Parametric Microphone Equalizer menu settings have all been set to "OFF ("100 TAUD PE1 FRQ "103 OFF" FRQ", 103 OFF 100 FRQ", 106 FRQ"). Press the PTT switch on the microphone, and speak into the microphone in a normal voice level. Observe the level indicated on the COMP meter scale. Adjust the compression level of the Speech Processor via the Menu Item "109 TGEN PROCLVL so that the PROCLVL" 109 meter needle does not indicate more than "10 dB" on the COMP meter scale. See Box at the right for details of the setting. [PROC] Button [MIC GAIN] Knob [METER] Button 6. To switch the Speech Processor off, press the [PROC] button once more. The " " and " " icons will turn off, confirming that the Speech processor is turned off. ADVICE: Excessive advancement of the compression gain will result in a degradation of the transmitted signal's signal-to-noise ratio, thereby reducing intelligibility at the other end of the circuit. The Transmit Monitor is a very helpful way to verify proper adjustment of the compression level. Pressing the [MONI] button and then adjusting the [MONI] knob for a comfortable listening level while you are transmitting, you will be able to hear the difference in sound quality as you make adjustments. You may set the RF power output via the Menu item "111 TGEN TX PWR whether or not the Speech ProPWR", 111 cessor is engaged. You may adjust the Parametric Microphone Equalizer when the speech processor is engaged, using Menu Items "100 through "108 See page 117 for de100" 108". When the optional DMU-2000 Data Management Unit is connected, you may observe the effect of your compression level adjustments by viewing the waveform on the "Oscilloscope" page. Adjusting the compression level of the Speech Processor 1. Press the [METER] button repeatedly to select "COMP" (Compression) meter. Press the [MENU] button to engage the Menu. Rotate the [SELECT] knob to select Menu item "109 TGEN PROCLVL PROCLVL". 109 ADVICE: Press the [SELECT] knob to toggle the Menu item display between "109 TGEN and "PROCLVL PROCLVL". Press the PTT switch on the microphone, and speak into the microphone in a normal voice level. Rotate the [CLAR/VFO-B] knob so that the meter deflects to not more than "10 dB" on the COMP meter scale. Press and hold in the [MENU] button for one second to save the new setting and exit to normal operation. [SELECT] Knob [METER] Button [MENU] Button [CLAR/VFO-B] Knob Page 62 FT-950 OPERATING MANUAL ENHANCING TRANSMIT SIGNAL QUALITY ADJUSTING THE SSB TRANSMITTED BANDWIDTH (SSB MODE) For transmission on SSB, a default bandwidth of 2. 4 kHz is provided. This bandwidth provides reasonable fidelity along with good talk power, and is typical of the bandwidth used for decades for SSB transmission. The bandwidth may be varied by the operator, to provide different levels of fidelity or talk power, according to your preferences. [. . . ] Similarly, locate the Coaxial plug (labeled ) installed in jack (J1029) on the MAIN Unit. Unplug the Coaxial plug ( ) from the MAIN Unit and plug it into the J7003 on the SCOPE Unit. Referring to Figure 4, lay out the Coaxial cables into the slits of the chassis. Replace the bottom case and its 18 screws. FIGURE 1 14-pin plug SCOPE Unit Mounting Location FIGURE 2 Move the Coaxial plug Plug the 14-pin plug Lay out the Coaxial cables into the slit Move the Coaxial plug FIGURE 3 FIGURE 4 Page 124 FT-950 OPERATING MANUAL INSTALLATION OF OPTIONAL ACCESSORIES DATA MANAGEMENT UNIT (DMU-2000) Interconnections to FT-950 Connect the DMU-2000 and FT-950 transceiver, your after market Display, and your after market Keyboard (if used) as shown in Figure 5. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAESU FT-950

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAESU FT-950 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag