User manual YAMAHA DME8I-ES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YAMAHA DME8I-ES. We hope that this YAMAHA DME8I-ES user guide will be useful to you.

Lastmanuals help download the user guide YAMAHA DME8I-ES.


Mode d'emploi YAMAHA DME8I-ES
Download
Manual abstract: user guide YAMAHA DME8I-ES

Detailed instructions for use are in the User's Guide.

[. . . ] DIGITAL MIXING ENGINE SATELLITE Owner's Manual EN Explanation of Graphical Symbols CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The above warning is located on the top of the unit. IMPORTANT SAFETY INSTRUCTIONS 1 2 3 4 5 6 7 8 Read these instructions. Install in accordance with the manufacturer's instructions. [. . . ] · Make sure that the USB-MIDI Driver's THRU setting is "OFF. " · Refer to "Network Settings" on page 19 for more information on assigning IP addresses from DME Designer. USB connections can be used in the following three ways: (1) Set up the network (e. g. , assign a unique IP address to each DME Satellite) from DME Designer. (2) Control the DME Satellite from DME Designer. (3) Connect to any individual DME Satellite and control that DME Satellite unit by transmitting MIDI commands from a MIDI sequencer or similar software. N OT E · The computer on which DME Designer is running can be connected to either the group master or a slave DME series unit. In this case, set the DME Satellite as the group master. · The correspondence between the MIDI commands to be received/transmitted and the scene parameters can be set up using DME Designer. · The USB port being used by DME Designer is not available for use by a MIDI sequencer or other application. Device Group USB Cable DME Satellite Ethernet Cable Switching Hub Ethernet Straight Cable Computer (Running DME Designer. ) Ethernet Cable DME64N/24N DME Satellite SCENE HOME UTILITY LEVEL MUTE CANCEL ENTER USB Cable Computer (Running MIDI Sequencer or similar application. ) 18 DME8i-ES/DME8o-ES/DME4io-ES Owner's Manual Connecting to a Computer Network Settings Use DME Designer to specify the IP address, master/slave, and master ID settings as follows. Setting the IP address Network Address Host Address Each group of digits between periods in an IP address is called an "octet. " These groups of digits are called "1st octet, " "2nd octet, " etc. , starting from the left-most digit group. You cannot specify 0, 127, or 223 through 255 for the 1st octet of the network address. You can specify the following range of values for the 4th octet. Master : 2-253 Slave : 3-253 NO T E · Subnet mask is fixed at 255. 255. 255. 0. · The network address of Gateway is the same as that of IP address. The host address of Gateway is automatically set to 254. · Assign each of DME series units a unique IP address so that there are no duplicates. Assigning duplicate IP addresses may cause serious network problems. · You cannot make any network settings while using the DME Designer application on-line. To make network settings, first set DME Designer off-line. Refer to the DME Designer Owner's Manual for details. Master and slave setting Each device group must have one master. All other devices in the group are assigned as slave. The fourth octet of a slave DME Satellite's master ID must be the same value as the fourth octet of the group master DME Satellite's IP address. NO T E DME8i-ES/DME8o-ES/DME4io-ES Owner's Manual 19 References Other Functions When using a DME Satellite together with the DME64N/24N, you must assign the DME Satellite (including the DME8i-C/ DME8o-C/DME4io-C) as the master. If you assign the DM64N/24N as the device group master, you will be unable to synchronize using DME Designer. Connecting to an External Device Audio I/O Connection Connecting to a Computer Controls and Connectors Introduction to the DME Satellite Foreword Foreword Introduction to the DME Satellite Controls and Connectors Connecting to a Computer Audio I/O Connection Connecting to an External Device Other Functions References Connecting to a Computer Ethernet Connection ([NETWORK] Connector) To control the DME Satellite from the computer via Ethernet, use an Ethernet cable to connect the [NETWORK] connector on the rear panel of the DME Satellite to the computer, then install DME-N Network Driver. N OT E · Refer to the "DME Setup Manual" (PDF file) for details on installing DME-N Network Driver. · Appropriate IP addresses must first be assigned to all devices connected to an Ethernet network. Connect your computer to one of the DME Satellite units via USB, then assign the IP addresses from DME Designer (page 18). Two DME Satellite units directly connected via Ethernet DME Satellite Ethernet Cable DME Satellite USB Cable You can connect devices in the same device group directly to each other using Ethernet cables, without connecting them to a switching hub. If they are DME Satellite units, you can use either crossover cables or straight cables. [. . . ] 135 Milner Avenue, Scarborough, Ontario, M1S 3R1, Canada Tel: 416-298-1311 POLAND Yamaha Music Europe GmbH Branch Sp. z o. o. 17 Stycznia 56, PL-02-146 Warszawa, Poland Tel: 022-868-07-57 ASIA THE PEOPLE'S REPUBLIC OF CHINA Yamaha Music & Electronics (China) Co. , Ltd. 2F, Yunhedasha, 1818 Xinzha-lu, Jingan-qu, Shanghai, China Tel: 021-6247-2211 U. S. A. Yamaha Corporation of America 6600 Orangethorpe Ave. , Buena Park, Calif. Tel: 714-522-9011 THE NETHERLANDS/ BELGIUM/LUXEMBOURG Yamaha Music Europe Branch Benelux Clarissenhof 5-b, 4133 AB Vianen, The Netherlands Tel: 0347-358 040 INDIA Yamaha Music India Pvt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA DME8I-ES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA DME8I-ES will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag