User manual YAMAHA PLG100-DX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YAMAHA PLG100-DX. We hope that this YAMAHA PLG100-DX user guide will be useful to you.

Lastmanuals help download the user guide YAMAHA PLG100-DX.


Mode d'emploi YAMAHA PLG100-DX
Download
Manual abstract: user guide YAMAHA PLG100-DX

Detailed instructions for use are in the User's Guide.

[. . . ] Precautions q Do not expose the plug-in board to direct sunlight, excessive humidity, high temperatures, excessive dust or strong vibrations. q Before handling the plug-in board, be sure to touch a metal surface to discharge any static electricity which may be in your body. q When holding the plug-in board, do not touch the inside area of the circuit board or apply excessive pressure to the board, and be sure to protect the board from contact with water or other liquids. q Before installing the plug-in board onto a tone generator/sound card, unplug the power connector of your computer. [. . . ] For example, if 1 is set, the change is by semitones, if 2 is set, it is by whole tones. 23 Editing DX Part Parameters PitBndStep (Pitch Bend Step) Setting Values : 0 to 12 Explanation: · Determines the way in which the pitch is changed by the pitch bend wheel. · The 0 value sets a continuous change (the normal setting). Setting 1 to 12 changes the sound according to the scale. For example, if 1 is set, the change is by semitones, if 2 is set, it is by whole tones. (AC4 Controller Assign) Settings: OFF, MOD, BC, FC, EXP, CAT, PB Explanation: · When the AC4 controller parameter is set to EGbias, this parameter sets the controller which operates EGbias. · The settings indicate controllers as follows: MOD . . . . . Modulation wheel Breath controller Foot controller Expression pedal Channel aftertouch Pitch bend wheel · When the amplitude modulation sensitivity of the selected voice has been set to carrier, operating the controller that has been set in this parameter will change the volume in realtime. When the amplitude modulation sensitivity has been set to modulator, the timbre will change. AC4CtrPrm1 (AC4 Controller Parameter 1) Settings: Off, EGbias Explanation: This specifies whether the EGbias will be controlled by the controller that has been set in the AC4 Control Change Number parameter. AC4CtrDpt1 (AC4 Controller Parameter Depth) Setting: -64 to +63 Explanation: Specifies the depth of operation when EGbias is controlled by the controller that has been set in the AC4 Control Change Number parameter. · When AC4CtrPrm1 has been set to EGbias, the sound may change when AC4CtrDept1 is set positive, even if the output from the controller set in AC4CCNo. is zero. 24 Editing DX Part Parameters RcvDxSysEx (Receive DX System Exclusive) Setting: OFF, ON Explanation: Specifies whether DX system exclusive messages will be received or not. · The follow conditions must be met for DX system exclusive messages to be received: With VCED, ACED (Parameter change, Bulk Dump) Bulk select: Custom Bank RcvDxSysEx: ON With VMEM, AMEM: (bulk dump, 32 voice bulk dump) RcvDxSysEx: ON 25 PLG100-DX System Parameters The parameters that apply to the entire system of the PLG100-DX are added to the utilities of the main XG tone generator. 1. Press the [UTIL] button. The menu screen for the Utility Mode will be displayed. 2. Pressing the [SELECT ] button and move the cursor to "PLUGIN, " then press the [ENTER] button. The plug-in board select screen will be displayed. 3. Press the [SELECT / ] buttons and move the cursor to the plug-in board to be edited, then press the [ENTER] button (select PLG100-DX here). The parameter screen for the selected plug-in board will be displayed. 4. Pressing the [SELECT / ] buttons, move the cursor to the parameter which is to be set. Change the value for the parameter using the [VALUE / ] buttons. 5. Press the [EXIT] button several times to return to the initial screen. 26 PLG100-DX System Parameters s System Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PartAssign Setting: 1 to 16, OFF Explanation: · Sets the part assigned to PLG100-DX. · When set to OFF, the parts will not be assigned. Settings 1 to 16 specify part numbers 1 to 16. BulkBlock Setting: 01-32, 33-64 Explanation: · Specifies which custom voice memory, 1 to 32 or 33 to 64, will be used for writing 32 voice bulk data sent to the PLG100-DX from an external MIDI device or computer. [. . . ] However, see Tables <2n> for the Address, Byte Count, and block. <1-1> Parameter Base Address MODEL ID = 4C Parameter XG SYSTEM (H) 00 00 00 08 Address (M) 00 00 00 00 0F 00 0F 02 (L) 00 7E 7F 00 00 00 00 00 Description System XG System On All Parameter Reset Multi Part 1 : Multi Part 16 Multi Part 1 : : Multi Part 16 PLG100-DX Part Assign MULTI PART 08 MULTI PART 0A (additional) PART ASSIGN 0A 70 42 Appendix <1-2> MIDI Parameter Change table ( XG SYSTEM ) Address Size Data Parameter (H) (H) (H) 000 4 00 - 0F MASTER TUNE 1 00 - 0F 2 00 - 0F 3 00 - 0F 4 5 6 7D 7E 7F TOTAL SIZE 1 1 1 1 1 1 7 ** Processed on the XG platform side (MU128, etc. ) <1-3> MIDI Parameter Address (H) 8 nn 0 nn 1 nn 2 nn 3 nn 4 nn 5 nn 6 00 - 7F 00 - 7F 28 - 58 0 0 MASTER VOLUME** MASTER ATTENUATOR** TRANSPOSE NOT USED XG SYSTEM ON ALL PARAMETER RESET Description -102. 4. . . 0. . . +102. 3[cent] 1st bit3-0bit15-12 2nd bit3-0bit11-8 3rd bit3-0bit7-4 4th bit3-0bit3-0 0. . . 127 0. . . 127 -24. . . 0. . . +24[semitones] 00=XG system ON (receive only) 00=ON (receive only) Default Value (H) 00 04 00 00 7F 0 40 -- -- Change table ( MULTI PART ) Size Data Parameter (H) (H) 1 NOT USED 1 00 - 7F BANK SELECT MSB 1 00 - 7F BANK SELECT LSB 1 00 - 7F PROGRAM NUMBER 1 00-1F, 7F Rcv CHANNEL 1 00 - 01 MONO/POLY MODE 1 00 - 02 SAME NOTE NUMBER Description Default Value (H) 0 0 0 Part No. 1 1 KEY ON ASSIGN 0 40 08 0. . . 127 0. . . 127 1. . . 128 A1. . . A16, OFF MONO, POLY SINGLE, MULTI, . . . nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn TOTAL nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn 7 8 9 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 SIZE 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 1 1 2 00 28 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 28 00 00 00 00 28 00 00 00 - 05 58 0F 0F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 58 7F 7F 7F 7F 58 7F 7F 7F PART MODE NOTE SHIFT DETUNE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 29 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 00 - 7F VOLUME** VELOCITY SENSE DEPTH VELOCITY SENSE OFFSET PAN** NOTE LIMIT LOW NOTE LIMIT HIGH DRY LEVEL** CHORUS SEND** REVERB SEND** VARIATION SEND** VIBRATO RATE VIBRATO DEPTH VIBRATO DELAY LOW PASS FILTER CUTOFF FREQUENCY LOW PASS FILTER RESONANCE EG ATTACK TIME EG DECAY TIME EG RELEASE TIME MW PITCH CONTROL MW LOW PASS FILTER CONTROL MW AMPLITUDE CONTROL** MW LFO PMOD DEPTH NOT USED MW LFO AMOD DEPTH BEND PITCH CONTROL BEND LOW PASS FILTER CONTROL BEND AMPLITUDE CONTROL** BEND LFO PMOD DEPTH NOT USED BEND LFO AMOD DEPTH NORMAL, . . . -24. . . 0. . . +24[semitones] -12. 8. . . 0. . . +12. 7[Hz] 1st bit3-0bit7-4 2nd bit3-0bit3-0 0. . . 127 0. . . 127 0. . . 127 C, L63. . . C. . . R63 C-2. . . G8 C-2. . . G8 0. . . 127 0. . . 127 0. . . 127 0. . . 127 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -24. . . 0. . . +24[semitones] -9600. . . 0. . . +9450[cent] -100. . . 0. . . +100[%] 0. . . 127 0. . . 127 -24. . . 0. . . +24[semitones] -9600. . . 0. . . +9450[cent] -100. . . 0. . . +100[%] 0. . . 127 0. . . 127 00 64 40 40 40 0 7F 7F 0 28 0 40 40 40 40 40 40 40 40 40 40 40 0A -- 0 42 40 40 0 -- 0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 - 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 00 - 01 Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv Rcv NOT Rcv PITCH BEND CH AFTER TOUCH(CAT) PROGRAM CHANGE CONTROL CHANGE POLY AFTER TOUCH(PAT) NOTE MESSAGE RPN NRPN MODULATION VOLUME PAN EXPRESSION HOLD1 PORTAMENTO SOSTENUTO USED BANK SELECT OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, OFF, ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON OFF, ON 1 1 1 1 1 1 1 XGmode=01, GMmode=00 1 1 1 1 1 1 1 -- XGmode=01, GMmode=00 43 Appendix nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn TOTAL nn nn nn nn TOTAL nn nn nn nn nn nn nn nn nn nn nn nn TOTAL 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E SIZE 70 71 72 73 SIZE 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F SIZE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3F 1 1 1 1 4 1 1 1 1 1 1 1 1 1 1 1 1 0C 1 1 2 00 00 00 00 00 00 00 00 00 00 00 00 28 00 00 00 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 7F 58 7F 7F 7F SCALE TUNING C SCALE TUNING C# SCALE TUNING D SCALE TUNING D# SCALE TUNING E SCALE TUNING F SCALE TUNING F# SCALE TUNING G SCALE TUNING G# SCALE TUNING A SCALE TUNING A# SCALE TUNING B CAT PITCH CONTROL CAT LOW PASS FILTER CONTROL CAT AMPLITUDE CONTROL** CAT LFO PMOD DEPTH NOT USED CAT LFO AMOD DEPTH PAT PITCH CONTROL NOT USED PAT AMPLITUDE CONTROL** PAT LFO PMOD DEPTH NOT USED PAT LFO AMOD DEPTH AC1 CONTROLLER NUMBER AC1 PITCH CONTROL AC1 LOW PASS FILTER CONTROL AC1 AMPLITUDE CONTROL** AC1 LFO PMOD DEPTH NOT USED AC1 LFO AMOD DEPTH AC2 CONTROLLER NUMBER AC2 PITCH CONTROL AC2 LOW PASS FILTER CONTROL AC2 AMPLITUDE CONTROL** AC2 LFO PMOD DEPTH NOT USED AC2 LFO AMOD DEPTH PORTAMENTO SWITCH PORTAMENTO TIME PITCH EG INITIAL LEVEL PITCH EG ATTACK TIME PITCH EG RELEASE LEVEL PITCH EG RELEASE TIME VELOCITY LIMIT LOW VELOCITY LIMIT HIGH -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -64. . . 0. . . +63[cent] -24. . . 0. . . +24[semitones] -9600. . . 0. . . +9450[cent] -100. . . 0. . . +100[%] 0. . . 127 0. . . 127 -24. . . 0. . . +24[semitones] -100. . . 0. . . +100[%] 0. . . 127 0. . . 127 0. . . 95 -24. . . 0. . . +24[semitones] -9600. . . 0. . . +9450[cent] -100. . . 0. . . +100[%] 0. . . 127 0. . . 127 0. . . 95 -24. . . 0. . . +24[semitones] -9600. . . 0. . . +9450[cent] -100. . . 0. . . +100[%] 0. . . 127 0. . . 127 OFF, ON 0. . . 127 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 1. . . 127 1. . . 127 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 0 -- 0 40 -- 40 0 -- 0 10 40 40 40 0 -- 0 11 40 40 40 0 -- 0 0 0 40 40 40 40 1 7F 00 - 7F 28 - 58 00 - 7F 00 - 7F 00 00 28 00 00 00 00 00 28 00 00 00 00 00 00 00 00 00 00 01 01 7F 5F 58 7F 7F 7F 7F 5F 58 7F 7F 7F 7F 01 7F 7F 7F 7F 7F 7F 7F 00 - 7F 00 - 7F NOT USED NOT USED EQ BASS GAIN EQ TREBLE GAIN -12 - +12[dB] -12 - +12[dB] -- -- 40 40 04 - 28 1C - 3A NOT USED NOT USED EQ BASS FREQUENCY EQ TREBLE FREQUENCY NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED 32. . . 2. 0k[Hz] 500. . . 16. 0k[Hz] -- -- 0C 36 -- -- -- -- -- -- -- -- 0A nn 20 nn 21 TOTAL SIZE 00 - 7F HIGH PASS FILTER CUTOFF FREQUENCY NOT USED -64. . . 0. . . +63 40 -- nn = PART NUMBER ** Processed on the XG platform side (MU128, etc. ) <1-4> MIDI Parameter Address (H) 70 2 nn TOTAL SIZE Change table ( PART ASSIGN ) Size Data Parameter (H) (H) 1 00 - 0F, 7F Part Assign 1 Description A1. . . A16, OFF Default Value (H) 0 nn = PLG100-DX Serial Number 44 Appendix <2-1> Parameter Base Address MODEL ID = 62 Parameter PLG100-DX SYSTEM PLG100-DX MULTI PART (H) 00 60 Address (M) 00 00 (L) 00 00 Description System Multi Part 1 : : Multi Part 16 60 <2-2> MIDI Parameter Address (H) 007 8 9 0A 0B 0C 0D 0E 0F TOTAL SIZE <2-3> MIDI Parameter Address (H) 60 nn 0 nn 1 nn 2 nn 3 nn 4 nn 5 nn 6 nn 7 nn 8 nn 9 nn 0A nn 0B nn 0C nn 0D nn 0E nn 0F nn 10 nn 11 nn 12 nn 13 nn 14 nn 15 nn 16 nn 17 nn 18 nn 19 nn 1A nn 1B TOTAL SIZE 60 nn 1C nn nn nn TOTAL 1D 1E 1F SIZE 0F 00 Change table ( PLG100-DX Native SYSTEM ) Size Data Parameter (H) (H) 1 NOT USED 1 00 - 06 VELOCITY CURVE 1 NOT USED 1 NOT USED 1 NOT USED 1 NOT USED 1 NOT USED 1 00 - 01 32 BULK RECEIVE BLOCK 1 NOT USED 9 Description DX, normal, Soft1, Soft2, Easy, Wide, Hard 1-32, 33-64 Default Value (H) -- 1 -- -- -- -- -- 0 -- Change table ( PLG100-DX Native MULTI PART ) Size Data Parameter (H) (H) 1 00 - 06 AC4 Controller 1 00 - 01 AC4 Parameter Select 1 NOT USED 1 NOT USED 1 NOT USED 1 00 - 7F AC4 Parameter Depth 1 NOT USED 1 NOT USED 1 NOT USED 1 NOT USED 1 NOT USED 1 00 - 7F Carrier Level1 1 00 - 7F Carrier Level2 1 00 - 7F Carrier Level3 1 00 - 7F Carrier Level4 1 00 - 7F Carrier Level5 1 00 - 7F Carrier Level6 1 NOT USED 1 NOT USED 1 00 - 7F Modulator Level1 1 00 - 7F Modulator Level2 1 00 - 7F Modulator Level3 1 00 - 7F Modulator Level4 1 00 - 7F Modulator Level5 1 00 - 7F Modulator Level6 1 NOT USED 1 NOT USED 1 39 - 47 FeedBack Level 1C 1 1 1 1 4 00 - 01 00 - 0C 00 - 0C Portamento Mode Portamento Step PitchBend Step NOT USED Description Off, MOD, BC, FC, EXP, CAT, PB Noassign, EGbias -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -64. . . 0. . . +63 -7. . . 0. . . +7 Default Value (H) 0 0 0 0 0 40 40 40 40 0 0 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 0:retain(poly), fingered(mono), 1:follow(mono), fulltime(poly) 0. . . 12 0. . . 12 1 0 0 0 nn 20 1 00 - 01 nn = PART NUMBER RcvDxSysEx 0:OFF 1:ON 1 <3-1> Parameter Group Number Parameter Group No. g h 00 00 00 01 06 00 Description VCED(Voice Edit Buffer) VCED(Voice Edit Buffer) ACED(Additional Edit Buffer) parameter# 0. . . 127 0. . . 28 0. . . 73 45 Appendix <3-2> MIDI Parameter Change table ( DX Voice Parameter - VCED format ) Parameter Group# Parameter# Size Data g h OP6 OP5 OP4 OP3 OP2 OP1 (H) (H) (H) (H) (H) (H) (H) (H) (H) (H) 00 00 00 15 2A 3F 54 69 1 00 - 63 00 01 16 2B 40 55 6A 1 00 - 63 00 02 17 2C 41 56 6B 1 00 - 63 00 03 18 2D 42 57 6C 1 00 - 63 00 04 19 2E 43 58 6D 1 00 - 63 00 05 1A 2F 44 59 6E 1 00 - 63 00 06 1B 30 45 5A 6F 1 00 - 63 00 07 1C 31 46 5B 70 1 00 - 63 00 08 1D 32 47 5C 71 1 00 - 63 00 09 1E 33 48 5D 72 1 00 - 63 00 0A 1F 34 49 5E 73 1 00 - 63 00 0B 20 35 4A 5F 74 1 00 - 03 00 0C 21 36 4B 60 75 1 00 - 03 00 0D 22 37 4C 61 76 1 00 - 07 00 0E 23 38 4D 62 77 1 00 - 03 00 0F 24 39 4E 63 78 1 00 - 07 00 10 25 3A 4F 64 79 1 00 - 63 00 11 26 3B 50 65 7A 1 00 - 01 00 12 27 3C 51 66 7B 1 00 - 1F 00 13 28 3D 52 67 7C 1 00 - 63 00 14 29 3E 53 68 7D 1 00 - 0E 00 00 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 7E 7F 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 63 63 63 63 63 63 63 63 !F 07 01 63 63 63 63 01 05 Parameter Description Default Value (H) 63 63 63 63 63 63 63 00 27 00 00 00 00 00 00 00 OP1=99, otherOP=0 00 01 00 07 63 63 63 63 32 32 32 32 00 00 01 23 00 00 00 01 00 EG RATE1 EG RATE2 EG RATE3 EG RATE4 EG LEVEL1 EG LEVEL2 EG LEVEL3 EG LEVEL4 BREAK POINT LEFT DEPTH RIGHT DEPTH LEFT CURVE RIGHT CURVE RATE SCALING AMPLITUDE MODULATION SENSITIVITY TOUCH SENSITIVITY TOTAL LEVEL FREQUENCY MODE FREQUENCY COURSE FREQUENCY FINE DETUNE PEG RATE1 PEG RATE2 PEG RATE3 PEG RATE4 PEG LEVEL1 PEG LEVEL2 PEG LEVEL3 PEG LEVEL4 ALGORITHM SELECTOR FEEDBACK LEVEL OSC PHASE INIT LFO SPEED LFO DELAY TIME PITCH MODULATION DEPTH AMPLITUDE MODULATION DEPTH LFO KEY SYNC LFO WAVE 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 A-1. . . C8 0. . . 99 0. . . 99 -lin, -exp, +exp, +lin -lin, -exp, +exp, +lin 0. . . 7 0. . . 3 0. . . 7 0. . . 99 ratio, fixed 0. . . 31 0. . . 99 -7. . . 0. . . +7 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 0. . . 99 1. . . 32 0. . . 7 off, on 0. . . 99 0. . . 99 0. . . 99 0. . . 99 off, on triangle, sawdown, sawup, square, sine, s/hold 0. . . 7 C1. . . C5 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 32. . . 127 (ASCII CHARACTER) 01 01 01 01 01 01 01 01 01 01 01 01 TOTAL SIZE 01 9B 0F 10 11 12 13 14 15 16 17 18 19 1A 1 1 1 1 1 1 1 1 1 1 1 1 00 00 25 25 25 25 25 25 25 25 25 25 - 07 2F 58 58 58 58 58 58 58 58 58 58 LFO PITCH MODULATION SENSITIVITY TRANSPOSE VOICE NAME VOICE NAME VOICE NAME VOICE NAME VOICE NAME VOICE NAME VOICE NAME VOICE NAME VOICE NAME VOICE NAME 03 18 `I' `N' `I' `T' `V' `O' `I' `C' `E' 1B 1 00 - 3F OPERATOR ENABLE Bit5:OP1, Bit4:OP2, Bit3:OP3, 3F Bit2:OP4, Bit1:OP5, Bit0:OP6 off, on <3-3> MIDI Parameter Change table ( DX Voice Additional Parameter - ACED format ) Parameter Group# Parameter# Size Data Parameter g h (H) (H) (H) (H) (H) 06 00 00 1 NOT USED 01 1 NOT USED 02 1 NOT USED 03 1 NOT USED 04 1 NOT USED 05 1 NOT USED 06 1 00 - 07 OP6 AMPLITUDE 07 1 00 - 07 OP5 AMPLITUDE 08 1 00 - 07 OP4 AMPLITUDE 09 1 00 - 07 OP3 AMPLITUDE 0A 1 00 - 07 OP2 AMPLITUDE 0B 1 00 - 07 OP1 AMPLITUDE Description Default Value (H) -- -- -- -- -- -- 00 00 00 00 00 00 MODULATION MODULATION MODULATION MODULATION MODULATION MODULATION SENSITIVITY SENSITIVITY SENSITIVITY SENSITIVITY SENSITIVITY SENSITIVITY 0. . . 7 0. . . 7 0. . . 7 0. . . 7 0. . . 7 0. . . 7 46 Appendix 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 40 41 42 43 44 45 46 47 48 49 TOTAL SIZE 31 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 00 00 00 00 00 00 00 00 00 00 - 03 01 01 03 0C 0C 07 01 0C 63 00 - 07 PITCH EG RANGE LFO KEY TRIGGER PITCH EG BY VELOCITY SWITCH POLY/MONO, UNISON SWITCH PITCH BEND RANGE PITCH BEND STEP NOT USED RANDOM PITCH FLUCTUATION PORTAMENTO MODE PORTAMENTO STEP PORTAMENTO TIME NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED PITCH EG RATE SCALING DEPTH NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED UNISON DETUNE DEPTH NOT USED 8va, 2va, 1va, 1/2va single, multi off, on bit0:poly/mono, bit1:unison off/on 0. . . 12 0. . . 12 0. . . 7 rtn/flw, fingrd/flltm 0. . . 12 0. . . 99 0. . . 7 00 00 00 00 02 00 -- 00 00 00 00 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 00 -- 00 - 07 0. . . 7 <4-1> Parameter Group Number Format No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA PLG100-DX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA PLG100-DX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag