User manual YORKVILLE CR5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual YORKVILLE CR5. We hope that this YORKVILLE CR5 user guide will be useful to you.

Lastmanuals help download the user guide YORKVILLE CR5.


Mode d'emploi YORKVILLE CR5
Download

You may also download the following manuals related to this product:

   YORKVILLE CR5 SERVICE MANUAL (1183 ko)

Manual abstract: user guide YORKVILLE CR5

Detailed instructions for use are in the User's Guide.

[. . . ] Lors de l'utilisation de produits électrique, assurezvous d'adhérer à des précautions de bases incluant celle qui suivent: Power Sources Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the unit. Do not use with an extension cord or receptacle unless the plug can be fully inserted. Precautions should be taken so that the grounding scheme on the unit is not defeated. Alimentation Hazards Do not place this product on an unstable cart, stand, tripod, bracket or table. [. . . ] The product may fall, causing serious personal injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the manufacturer or sold with the product. Follow the manufacturer's instructions when installing the product and use mounting accessories recommended by the manufacturer. The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be placed on the apparatus. Terminals marked with the "lightning bolt" are hazardous live; the external wiring connected to these terminals require installation by an instructed person or the use of ready made leads or cords. Ensure that proper ventilation is provided around the appliance. No naked flame sources, such as lighted candles, should be placed on the apparatus. L'appareil ne doit être branché qu'à une source d'alimentation correspondant au voltage spécifié dans le manuel ou tel qu'indiqué sur l'appareil. Cet appareil est équipé d'une prise d'alimentation polarisée. 6405 6408 6419 6425 6825 6438 6827 6733 6488 6461 6824 6465 6463 6466 5101 5102 5103 5104 5108 5109 5110 5119 6808 6809 6873 6874 6988 6991 6840 6882 6745 5190 6444 6478 5817 5203 5199 5415 5211 5816 5206 5273 5428 5209 6451 5204 6435 5224 5228 5314 5231 5257 5259 5281 5961 5883 5630 5896 4497 4520 2417 3819 3410 3415 3498 3417 3405 3416 3501 3745 3806 3801 8661 3481 3834 3521 3538 5989 8793 8800 8854 8797 3846 3866 3870 8581 4597 Description RED 3MM LED 1V7 5MA BRT GRN 3MM LED 1V9 5MA FROSTED BRIDGE 35A 400V WIRE LEAD GI3504 BAV21 200V 0A25 DIODE T&R 1N4148 75V 0A45 DIODE T&R 1N4004 400V 1A0 DIODE T&R 1N5402 200V 3A0 DIODE BAT85 30V 0A2 DIODE SCHTKYT&R 1N5236BRL 7V5 0W5 ZENER 5% T&R 1N5240BRL 10V0 0W5 ZENER 5% T&R 1N5246B 16V0 0W5 ZENER 5% T&R 1N5250B 20V0 0W5 ZENER 5% T&R 1N5251BRL 22V0 0W5 ZENER 5% T&R 1N5256B 30V0 0W5 ZENER 5% T&R BC550C TO92 NPN TRAN T&R TB BC560C TO92 PNP TRAN T&R TB MPSA06 TO92 NPN TRAN T&R TA MPSA56 TO92 PNP TRAN T&R TA 2N5401 TO92 PNP TRAN T&R TA MPSA43 TO92 NPN TRAN TA MPSA93 TO92 PNP TRAN TA 2N5638 TO92 NCH JFET T&R TC MJE15032 TO220 NPN TRAN TE MJE15033 TO220 PNP TRAN TE MJE340 TO126 NPN TRAN TG MJE350 TO126 PNP TRAN TG MJL21194 TO3P NPN TRAN TK MJL21193 TO3P PNP TRAN TK MC33078P IC DUAL OP AMP TL072CP IC FET DUAL OP AMP LM13600N IC XCONDUCTANCE AMP MBS4992 TO92 8V5 DIAC MAC224-4 TO220 40A TRIAC 200V AS35FN-TO92 TEMPERATURE SENSOR _15P 100V 2%CAP T&R RAD CER. 2"NPO _47P 100V 2%CAP T&R RAD CER. 2"NPO 100P 100V 2%CAP T&R RAD CER. 2"NPO 180P 100V 2%CAP T&R RAD . 2" 330P 100V 5%CAP T&R RAD CER. 2"NPO 680P 100V 5%CAP T&R RAD CER. 2"NPO __1N 400V 5%CAP T&R RAD . 2"FLM __1N5 200V 5%CAP T&R RAD CER. 2"NPO __3N3 50V 10%CAP T&R BEAD Y5R __4N7 250V 5%CAP T&R RAD . 2"FLM __4N7 250V 20%CAP BLK 'Y' 10MM AC _10N 100V 10%CAP T&R RAD . 2"FLM _22N 275V 20%CAP BLK 'X2' 15MM AC _47N 100V 10%CAP T&R RAD . 2"FLM 100N 100V 5%CAP T&R RAD . 2"FLM 100N 50V 10%CAP T&R BEAD X7R 220N 63V 10%CAP T&R RAD . 2"FLM __2U2 63V 20%CAP T&R RAD . 2"EL __4U7 63V 20%CAP T&R RAD . 2"EL _10U 16V 20%CAP T&R RAD . 2"NP _33U 16V 20%CAP T&R RAD . 2"NP 220U 100V 20%CAP BLK 12X21MM EL 330U 25V 20%CAP BLK 10X13MM EL 4700U 80V 20%CAP BLK 25X50MM ELS _10K B LIN 9MM HORIZONTAL P29 _10K TRIM POT 6. 00 AMP CIRCUIT BREAKER . 250 TAB ___5UH COIL 18AWG R000 AIR CORE RED ON LEFT DUAL BINDING POST TPP5 RED ON RIGHT DUAL BINDING POST TPP5 1/4" JCK PCB MT HORZ 6-32 SCREW TERMINAL PC MOUNT TERMINAL STRIP 5P #6 SCREW 1/4"&XLR PCB MT VERT COMBO B52200F006 COMP WASH #4 SMALL DUAL XSISTOR PBL SPRING PLATE ZN RECTANGULAR WASHER FOR TRANS SUPPRT 5/8" BUMPER BUTTON BLACK BUTTON KNOB FLAT GREY 8' 3/18 SJT AC LINE CORD 250 CLIPS HEYCO #1214 STRAIN RELIEF SIDE ENTRY PCB CONN . 156 8POS 24 PIN BREAKAWAY LOCK . 156 4 CIR CABLE HOLDER . 098 4-40 HEX NUT ZINC 6-32 KEPS NUT ZINC 6-32 X 1/4 HEX NUT ZINC 5/16-18 KEPS NUT JS500 TO220 THERMO PAD LARGE HOLE 56359B ELASTOMER PAD TSIL 3 1. 2X6. 0 TO220 MICA PAD LARGE HOLE PRE-GREA CUSTOM PBL TRANSISTOR SPACER 22AWG STRAN TC WIR JMP Qty. 2 1 1 4 34 6 4 4 4 1 6 1 2 2 3 7 6 6 2 2 2 5 2 2 1 1 4 4 2 4 1 2 2 2 4 2 2 2 8 4 2 2 2 4 1 5 1 2 5 1 5 4 8 4 4 4 4 4 2 2 1 2 1 1 2 1 1 2 6 4 4 4 1 1 1 2 0. 67 2 6 10 1 1 2 2 4 4 70 YS No. 4599 5299 4715 4877 4748 4686 4875 4816 4607 4608 4852 4645 4770 6204 4872 5029 4743 4873 4758 4823 4981 4919 4693 4764 4826 5022 5028 4774 4982 4639 4685 4887 4787 5004 5027 4800 4829 4983 4773 4630 4830 4831 4885 6123 4777 4840 5009 4908 4834 6119 4760 5007 4838 6120 5026 4841 6126 4880 4820 4845 4846 3565 3619 8741 8827 8832 8801 8829 8806 8828 8874 8911 8821 8740 3744 3741 3743 8657 8667 8818 3436 3587 3705 1195 Description 22AWG SOLID SC WIR T&R JMP 24AWG SOLID SC WIR RAD JMP 5. 0W 0R20 5% BLK RES 1/4W 1R 5%FLAME PROOF T&R RES 2. 0W 3R9 5% T&R 1. 0W 10R 5%FLAME PROOF T&R RES 1/4W 10R 5% T&R RES 1/4W 33R 5% T&R RES 1/8W 39R 2%FLAME PROOF T&R RES 1/8W 75R 2%FLAME PROOF T&R RES 1/4W 100R 5% T&R RES 1/8W 220R0 1%FLAME PROOF T&R RES 1/4W 249R 1% T&R RES 1/4W 332R0 1%FLAME PROOF T&R RES 1/4W 390R 5% T&R RES 1/4W 499R 1% T&R RES 1/4W 681R0 0. 1% *** T&R RES 1/4W 680R 5% T&R RES 1/4W 953R 1% T&R RES 1/4W 1K 5% T&R RES 1/4W 1K 5%MINI T&R RES 1/4W 2K05 1%-NO SUBS- T&R RES 5. 0W 2K2 5% BLK RES 1/4W 2K740 0. 1% *** T&R RES 1/4W 3K3 5% T&R RES 1/4W 3K57 1% T&R RES 1/4W 3K74 1% T&R RES 1/4W 4K12 1% T&R RES 1/4W 4K7 5%MINI T&R RES 1/4W 4K99 1% T&R RES 1. 0W 5K6 5% T&R RES 1/4W 7K5 5% T&R RES 1/4W 7K960 0. 1% *** T&R RES 1/4W 8K06 1% T&R RES 1/4W 9K09 1% T&R RES 1/4W 10K0 1% T&R RES 1/4W 10K 5% T&R RES 1/4W 10K 5%MINI T&R RES 1/4W 12K1 1% T&R RES 1/2W 15K 5% T&R RES 1/4W 15K 5% T&R RES 1/4W 18K 5% T&R RES 1/4W 20K 5% T&R RES 1/4W 20K0 1%MINI MF T&R RES 1/4W 21K5 1% T&R RES 1/4W 33K 5% T&R RES 1/4W 40K2 1% T&R RES 1/4W 45K3 1% T&R RES 1/4W 47K 5% T&R RES 1/4W 47K 5%MINI T&R RES 1/4W 75K 5% T&R RES 1/4W 78K7 1% T&R RES 1/4W 100K 5% T&R RES 1/4W 100K 5%MINI T&R RES 1/4W 143K 1% T&R RES 1/4W 220K 5% T&R RES 1/4W 220K 5%MINI T&R RES 1/4W 680K 5% T&R RES 1/4W 1M5 5% T&R RES 1/4W 2M2 5% T&R RES 1/4W 3M3 5% T&R RES 10" 4C-28AWG RIBBON CABLE 0. 1" 4. 75 8C-22AWG RIB 3/4" NOTCH 156 4-40 X 1/2 PAN PH MS JS500 4-40 X 1/2 FLAT PH TAPTITE JS500 6-32 X 1/4 PAN PH TAPTITE JS500 6-32 X 3/8 PAN PH TAPTITE JS500 6-32 X 3/8 FLAT PH TAPTITE BO#4 HEA 6-32 X 1/2 PAN PH TAPTITE JS500 6-32 X 3/4 PAN PH TAPTITE JS500 8-32 X 1" PAN PHIL TAPTITE JS500 10-16 X 1/2 TYPE B HEX W/SLOT BL 10-16 X 1 3/32 TYPE B HEX W/SLOT BL 5/16-18 X 3 GRD 5 HEX BOLT JS500 SNAP IN . 375 SPACER RICHCO . 5 SPACER ID-. 171 OD-. 25 #912-500 SNAP ON 0. 5" SPACER RICHCO 6-32 X 3/8" HEX SPACER ALUMINUM SHOULDER WASHER SWS-229 LENGTH 1/8 3/4 OD X 5/16 ID X . 08 THICK WASHER DPDT PUSH SW PCMT H BREAK B4 MAKE DPDT ROKR SW QUIK 250"AC/PWR ON-OFF 4P3T SLID SW PCMT H CR5 120VAC 60HZ XFMR Qty. 90 8 8 12 2 2 6 4 2 4 2 2 4 2 2 2 2 1 4 1 7 6 4 4 2 7 8 2 2 8 2 2 2 6 2 4 8 4 4 7 2 2 2 1 4 2 7 2 13 2 4 1 5 4 4 2 2 1 2 1 2 1 2 6 4 1 14 29 2 6 8 16 4 1 6 2 8 1 4 1 1 1 1 1 CW SG_B R22 953R SW1 330P R23 3K74 C12 330P TLO72 9 C11 1/2 TLO72 R27 45K3 10K P2 B_GAIN TAP 33U C16 R28 L 143K R11 D22 U2 1/2 LVGND (6=V-, 11=V+) LM13600 12 1/2 U5 IABC 4148 COM 40K2 13 D 1W 10 M 11 R 12 13 L COM SW1 0. 5W 15 SG_B C31 80V 4700U 1 C34 80V 4700U C33 80V 4700U 15K R74 15K PSGND R110 C32 80V 4700U 15K R73 0. 5W +65V M R68 14 R 16 TAB1 BLACK 6AMPS WHITE PS1 TAB2 NEUTRAL WHITE TAB3 GREEN GROUND GREEN LIVE BLACK 0. 5W 0. 5W CSA C25 TAB5 22N PRIM BLACK CSA C26 4N7 1N4004 1N4004 D7 4 8A 2 +. 67V TAB4 PRIM BLACK #1195 0. 5W TAB8 SEC RED C28 25V 4U7 20K R50 1M5 R35 1K Q3 R36 1K Q4 2N5638 SG_B INPUT_B C40 4N7 Q13 BC560 5W D8 5W 5W 20K TO AMP A D11 R71 3M3 25V D10 4U7 C35 4U7 25V C36 +15V 100K -65V SG_A R54A C4A 180P D35A D36A 5uH R215A 1W 15K R67 1/2W PSGND R84 680K LVGND 4148 D19 (4=V-, 8V+) D38A D37A 10K0 R93A 2K05 R95A R94A 3K57 7V5 1N5236 D41A 0R2 R112A 0R2 R113A 16V 500mW D44A C15A 25V 330u C16A 63V 47N R110A 3R9 2W 10R 5W PSGND 1N5250 20V/1/2W R75 C42 47K 25V 2U2 R76 100K C43 R85 25V 47K 2U2 4148 D20 R79 47K R82 100K 4148 D17 4148 D26 R80 3M3 10V 1/2W D21 R72 680R 7 TLO72 1/2 U6 4148 D18 +65V TEMPB CLIPA TO AMP B 8 7 6 5 4 3 2 1 +16V_BAT INPUT_B SG_B SPKR-B SPKR+B CLIPB -65V D29A Q33A MPSA56 750R 680P R82A C13A (4=-16V_BAT, 8=+16V_BAT) 33078 1/2 TP2 75R0 FP 5W L1A REPLACE WITH SAME TYPE BUSSMAN GDC FUSE YS PT#2475 T3, 15A 4148 D13 CSA . ADJUST R60A/R60B FOR 4mV BIAS ACROSS R106 AND R112 COLD. Q30A&B ARE THERMALLY COUPLED TO HEAT SINK 3. B CE BC550C BC560C MPSA56 2N5401 BCE MPSA93 MPSA43 PSGND M1140. SCH_DATABASE_HISTORY MODEL(S):# DATE 1 2 3 4 5 6 7 8 9 10 OCT/08/99 NOV/04/99 NOV/11/99 . DEC/20/00 FEB/05/02 APR/25/06 D CR5 VER# DESCRIPTION OF CHANGE 1. 10 1. 20 1. 30 . [. . . ] DEC/20/00 FEB/05/02 APR/25/06 D CR5 VER# DESCRIPTION OF CHANGE 1. 10 1. 20 1. 30 . 1. 50 1. 60 1. 70 V ADD_HEATSINK_SYMBOL PC#6129_ADD_C44, C45 PC#6121_R90_21K5->8K06_R83_10K0-> 3K57 R99A, R100A, R101A, R103A, R104A, R105A 1/4WFP_TO_1/4W PC#6314_CE_FUSE_T3A->T3, 15A PC#6403_C17A-C22A_220u->330u PC#7007 MAC-224-4 TO STM-BTB-600BRG N TP TEST POINT 4. Reference with a "A" suffix for amplifier "A" and "B" suffix for amplifier "B" AMPLIFIER A SAME AS AMPLIFIER B. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YORKVILLE CR5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual YORKVILLE CR5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag