User manual ZANKER KRH40GN/1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANKER KRH40GN/1. We hope that this ZANKER KRH40GN/1 user guide will be useful to you.

Lastmanuals help download the user guide ZANKER KRH40GN/1.


Mode d'emploi ZANKER KRH40GN/1
Download
Manual abstract: user guide ZANKER KRH40GN/1

Detailed instructions for use are in the User's Guide.

[. . . ] English Important Safety Information These warnings are provided in the interest of safety. You must read them carefully before installing or using the appliance. Installation It is mandatory that all operations required for the installation are carried out by a qualified or competent person, in accordance with existing rules and regulations. It is dangerous to alter the specification in any way. Should you connect any electrical tool to a plug near this cooking appliance, ensure that electric cables are not in contact with it and keep them far enough from the heated parts of this appliance. [. . . ] Use some soapy water, never a flame. Gas connection It is indispensible that the connection to the gas mains are carried out by means of an AGB tap. Choose fixed connections or use a flexible pipe in AGB (stainless steel). If using flexible metallic pipes, be careful they do not come in contact with mobile parts or they are not squeezed. Use the same attention when the hob is combinated with an oven. This hob can be operated by Slochteren gas (G25) with a nominal pressure of 25 mbar or by natural gas with nominal pressure of 20 mbar. No regulation is required for use by these two types of gas. Before fitting the appliance ensure that the installation has the correct voltage for the appliance. At full capacity, the drop in pressure must not exceed 5%. Such a drop in pressure is caused by the following parameters: - maximum capacity of meter; - diameter and lenght of the tube in front and behind the meter; - section of transit of variuos tubes positioned on the circuit; - diameter of eventual connections. FO 2365 A) Ramp with ending nut B) Seal C) Adjustable connection Fig. 4 33 Electrical Connection The appliance is designed to be connected to 230 V monophase electricity supply. The connection must be carried out in compliance with the laws and regulations in force. Before the appliance is connected: 1) check that the main fuse and the domestic installation can support the load (see the rating label); 2) check that the power supply is properly earthed in compliance with the current rules; 3) check the socket or the double pole switch used for the electrical connection can be easily reached with the appliance built in the forniture unit. The appliance is supplied with a connection cable. This has to be provided with a proper plug, able to support the load marked on the identification plate. The plug has to be fitted in a proper socket. If connecting the appliance directly to the electric system, it is necessary that you install a double pole switch between the appliance and the electricity supply, with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current rules. The connection cable has to be placed in order that, in each part, it cannot reach a temperature higher than 90°C. The brown coloured phase cable (fitted in the terminal block contact marked with "L") must always be connected to the network phase. Replacement of the voltage cable In case the connection cable needs to be replaced, only cable type H05V2V2-F T90 must be used. The cable section must be suitable to the voltage and the working temperature. The yellow/green earth wire must be approximately 2 cm. Phase Neutral wire Ground (yellow - green) FO 0480 Fig. [. . . ] The statutory warranty does not apply when defects are caused by: · a chemical or electrochemical reaction caused by water, · abnormal environmental conditions in general, · unsuitable operating conditions, · contact with harsh substances. The guarantee does not apply to defects due to transport which have occurred outside of our responsibility. Nor will the guarantee cover those caused by inadequate installation or assembly, lack of maintenance or failure to respect the assembly instructions or directions for use. Defects that result from repairs or measures carried out by people who are not qualified or expert or defects that result from the addition of non-original accessories or spare parts are not covered by the guarantee. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANKER KRH40GN/1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANKER KRH40GN/1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag