User manual ZANUSSI PI44GK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI PI44GK. We hope that this ZANUSSI PI44GK user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI PI44GK.


Mode d'emploi ZANUSSI PI44GK
Download
Manual abstract: user guide ZANUSSI PI44GK

Detailed instructions for use are in the User's Guide.

[. . . ] Where this appliance is installed in marine craft or in caravans, it shall not be used as a space heater. The work of installation must be carried out by competent and qualified installers according to the regulations in force. The appliance must be installed at a minimum distance of 50 cm. from curtains or other combustible material. [. . . ] 240 mm 220 mm 160 mm The following instructions relating to installation and regulation must be carried out by qualified personnel. The appliance must be installed correctly in conformity with the rules and regulations in force. All interventions must be carried out with the appliance electrically disconnected. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR ANY DAMAGES DERIVING FROM AN INSTALLATION WHICH DOES NOT CONFORM WITH THE REGULATIONS IN FORCE. SITE OF INSTALLATION FO 0252 For a good operation of the gas appliance it is indispensable that the air necessary for gas combustion can circulate in the room in a natural manner. (The installer must follow the regulations in force. ) q The appliance must be installed at a minimum distance of 50 cm. from curtains or other combustible material. 6 7 CONNECTION TO THE GAS SUPPLY Gas connection must be carried out in conformity with the regulations in force. The appliance leaves the factory tested and regulated for the type of gas indicated on the plate which is situated in the lower position near the gas connection tube. Ascertain that the type of gas with which the appliance will be supplied is the same as that indicated on the plate. If different carry out all the operations according to the indications cited in the paragraph "adaption to different types of gas". For a maximum output and minimum consumption ascertain that the pressure of the gas used has the values indicated in the table of "burner characteristics". The joint is mounted on the intake area of the pipe, fitted with a filleted nut GJ 1/2, between the sealing components as shown in Fig. Screw the parts without forcing, turn the joint in the direction required and then tighten everything. A) Intake pipe with nut B) Adjustable joint C) Rigid metallic gas supply pipe Natual gas appliances must be fitted with a pressure regulator and be installed at the inlet connection. The gas pressure must then be set as a part of the commissioning procedures. For LPG the pressure adjustment is made via the regulator fitted at the domestic cylinder. Carry out the connection to the gas plant only by means of a rigid metallic pipe conforming to the regulations in force. The joint for the entry of gas into the appliance is threaded GJ 1/2". Carry out the connection avoiding any type of stress on the appliance. The adjustable joint permits the location of the supply tube in the appropriate site situated on the side of the protection box of the hob itself (Fig. This system permits the total encumbrance of the hob plus the gas supply tube to be contained to a depth of 30 mm. CONNECTION ELECTRICAL CONNECTION YES RIGID METALLIC TUBE OR FLEXIBLE STAINLESS STEEL TUBE The appliance is predisposed to function with a 240V monophase voltage tension. Connection must be carried out in conformity with the regulations and dispositions of the laws in force. Before connecting ensure that: - The limiter valve and the electrical mains can support the voltage of the appliance (see registration plate). [. . . ] The electrical connection of the hob and that of the oven must be carried out separately, both for electrical reasons and to facilitate the frontal extraction of the oven. TECHNICAL ASSISTANCE AND SPARE PARTS 120 cm 2 50 cm 2 Before leaving the factory this appliance was tested and controlled by expert and specialized personnel in order to give the best working results. All repairs or controls which may be necessary should be undertaken with maximum care and attention. For this reason we recommend you always contact the Retailer who sold it or our nearest Assistance Centre, specifying the type of problem and the model of the appliance in your possession. Important!Nonetheless, to obtain the best results it is important that this brochure be read carefully and all the instructions followed before using for the first time. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI PI44GK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI PI44GK will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag