User manual ZANUSSI ZGF782CN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGF782CN. We hope that this ZANUSSI ZGF782CN user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZGF782CN.


Mode d'emploi ZANUSSI ZGF782CN
Download
Manual abstract: user guide ZANUSSI ZGF782CN

Detailed instructions for use are in the User's Guide.

[. . . ] GAS HOB ZGF782C INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB Important Safety Information You MUST read hese warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 727727 Installation l Service l l l l l This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Remove all packaging before using the hob. [. . . ] Home visits are made between 8. 30am and 5. 30pm Monday to Friday. Visits may be available outside these hours, in which case a premium will be charged. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: * The guarantee starts from the date you first purchased your product. * The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products. * This guarantee relates to you and cannot be transferred to another user. * Your new home is within the European Community (EC) or European Free Trade Area. * The product is installed and used in accordance with our instructions and is only used domestically, i. e. a normal household * The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0)3 44 62 29 99 Germany Nürnberg +49 (0)911 323 2600 Italy Pordenone +39 (0)1678 47053 Sweden Stockholm +46 (0)8 738 79 50 UK Slough +44 (0)1753 219897 Exclusions This guarantee does not cover: * Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or removable parts of glass or plastic. * Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom. 6 Instructions for the Installer Engineers technical data OVERALL DIMENSIONS Width: Depth: 680 mm. Ignition HT Spark Spark Generator Spark Gap Ispra Control's BF 50066 220- 240V 0. 6 VA T 120 Fixed Rear Left Burner (semi rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Left Burner (auxiliary) Heat Input 1. 0 kW (3413 BTU/HR) Rear Right Burner (semi rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Right Burner (rapid) Heat Input 3. 0 kW (10236 BTU/HR) Central Burner (Ultra-rapid Triple-crown) Heat Input 4. 0 kW (13652 BTU/HR) CUT OUT DIMENSIONS Width: Depth: 560 mm. 480 mm. SUPPLY CONNECTIONS Gas: R 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3 TYPE OF GAS BURNER RAPID (large) MAX MIN SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN ULTRA-RAPID (triple-crown) MAX MIN POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm NATURAL GAS 20 mbar 3. 0 0. 286 119 2. 8 202 86 0. 65 0. 062 Adjust. 0. 65 47 40 2. 0 0. 190 96 2. 0 144 71 0. 45 0. 043 Adjust. 0. 45 32 32 1. 0 0. 095 70 1. 0 72 50 0. 33 0. 031 Adjust. must be left between the side edges of the hob and any adjacent cabinets or walls. FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 600 mm 700 mm 400 mm 55 mm 400 mm 100 mm 50 m m 50 m m FO 2231* 8 Installation IMPORTANT: This hob must be installed by qualified personnel to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory. On the end of the shaft, which includes the G 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force. FO 0814 Gas Connection Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to R 1/2" (1/2 BSP male thread). [. . . ] Resistance should be less than 0. 1 W (Ohm), check all earth wires for continuity and all contacts are clean and tight. INSULATION CHECK - Appliance electrically disconnected, all switches ON. Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGF782CN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGF782CN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag