User manual ZANUSSI ZGF982CX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGF982CX. We hope that this ZANUSSI ZGF982CX user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZGF982CX.


Mode d'emploi ZANUSSI ZGF982CX
Download
Manual abstract: user guide ZANUSSI ZGF982CX

Detailed instructions for use are in the User's Guide.

[. . . ] GAS HOBS ZGF982C INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB Important Safety Information You MUST read hese warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 727727 Installation l Service l l l l l This hob must be installed by qualified personnel, according to the manufacturers instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Remove all packaging before using the hob. [. . . ] Estate Coventry Road Narborough Leicestershire LE0 5GF Unit 8 Stonefield Park Clifton Street Lincoln LN5 8AA 18-21 Croft Road Brampton Ind. Estate Newcastle under Lyme Staffordshire ST5 0TW 13 Thornhill Road North Moons Moat Redditch Worcestershire B98 9ND Unit 3 Sterling Park Claymore Tamworth B77 5DO Units 1 & 2 Northbrook Close Gregorys Mill Ind. Estate Worcester WR3 8BP LONDON & EAST ANGLIA BECKENHAM (M79) 11a Gardener Ind. Estate Kent House Lane Beckenham Kent BR3 1QZ Hanbury Road Widford Ind. Estate Chelmsford Essex CM12 3AE Unit 14 Capitol Park Capitol Way Colindale London NW9 0EQ 194 Court Road Mottingham Eltham London SE9 4EW 284 Alma Road Enfield London EN3 7BB Unit B4 Imperial Business Estate Gravesend Kent DA11 0DL Unit 4 Riverside Estate Coldharbour Lane Harpenden AL5 4UN 16-17 Woodside Ind. Estate Works Road Letchworth Herts SG6 1LA 2/4 Royal Lane Yiewsley West Drayton Middlesex UB7 8DL Reform Road Maidenhead Berkshire SL6 8BY 10 Island Farm Avenue West Molesey Surrey KT8 2UZ 9 Pipers Court Berkshire Drive Thatcham Berkshire RG19 4ER Unit 6C Elton Park Business Centre Hadleigh Road Ipswich IP2 0DD 2b Trafalgar Street Norwich NR1 3HN SUNBURY (M63) Unit 1a The Summit Hanworth Road Hanworth Ind. Estate Sunbury on Thames TW16 5D BOURNE (M44) CHELMSFORD (M47) SOUTH EAST ASHFORD (M58) Unit 2 Bridge Road Business Est. Bridge Road Ashford Kent TN2 1BB Unit 1 Redsfield Ind. Estate Church Crookham Fleet Hampshire GU13 0RD 21-25 Bridge Road Haywards Heath Sussex RH16 1UA BRIDGNORTH (M72) COLINDALE (M53) FLEET (M59) GLOUCESTER (M23) HEREFORD (M31) ELTHAM (M78) ENFIELD (M49) HAYWARDS HEATH (M55) SOUTH WEST BARNSTAPLE (M30) Main Road Fremington Barnstaple North Devon EX31 2NT 63-65 Curzon Road Bournemouth Dorset BH1 4PW 6 Hamp Ind. Estate Bridgewater Somerset TA6 3NT 11 Eldon Way Eldonwall Trading Bristol Avon BS4 3QQ 266 Main Road Southbourne Emsworth PO10 8JL Unit 8 Enterprise Court Ryde Business Park Ryde Isle of Wight PO33 1DB Unit 2 Zealley Ind. Estate Wilson Way Redruth Cornwall TR15 3QW HIGHAM FERRERS (M51) GRAVESEND (M57) ILKESTON (M43) LEICESTER (M22) HARPENDEN (M46) BOURNEMOUTH (M26) LETCHWORTH (M50) BRIDGEWATER (M35) BRISTOL (M25) LINCOLN (M40) LONDON (M76) EMSWORTH (M33) NEWCASTLE UNDER LYME (M12) MAIDENHEAD (M60) ISLE OF WIGHT (M34) REDDITCH (M20) MOLESEY (M61) NEWTON ABBOT (M29) TAMWORTH (M19) NEWBURY (M24) REDRUTH (M36) WORCESTER (M73) IPSWICH (M48) NORWICH (M52) 8 Instructions for the Installer Engineers technical data OVERALL DIMENSIONS Width: Depth: 860 mm. Ignition HT Spark Spark Generator Spark Gap Ispra Control's BF 50066 230- 240V 0. 6 YA T 120 Fixed Rear Left Burner (semi rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Left Burner (auxiliary) Heat Input 1. 0 kW (3412 BTU/HR) Rear Right Burner (semi rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Right Burner (rapid) Heat Input 3. 0 kW (10236 BTU/HR) Central Burner (Ultra-rapid Double-crown) Heat Input 3. 5 kW (11942 BTU/HR) CUT OUT DIMENSIONS Width: Depth: 830 mm. 480 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. VALUE = 37. 78 MJ/m3 CHARACTERISTICS Ws - 50. 7 MJ/ m3 TYPE OF GAS BURNER RAPID (large) MAX MIN SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN ULTRA-RAPID (double-crown) MAX MIN POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE g/h NOZZLE REFERENCE 1/100 mm NATURAL GAS 20 mbar 3. 0 0. 286 119 2. 8 202 86 0. 65 0. 062 Adjust. 0. 65 47 40 2. 0 0. 190 96 2. 0 144 71 0. 45 0. 043 Adjust. 0. 45 32 32 1. 0 0. 095 70 1. 0 72 50 0. 33 0. 031 Adjust. 0. 33 24 28 3. 5 0. 333 136 3. 2 231 88 1. 2 0. 114 Adjust. 1. 2 86 56 VALUE = 49. 92 MJ/Kg LPG GAS 28-30/37 mbar Burner Auxiliary Semi-rapid Rapid Ultra-rapid Dia. Tap By-pass 1/100 mm 28 32 40 56 APPLIANCE CLASS : 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar Aeration adjustment none 9 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. [. . . ] Resistance should be less than 0. 1 (Ohm), check all earth wires for continuity and all contacts are clean and tight. INSULATION CHECK - Appliance electrically disconnected, all switches ON. Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGF982CX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGF982CX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag