User manual ZANUSSI ZGG6420CN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGG6420CN. We hope that this ZANUSSI ZGG6420CN user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZGG6420CN.


Mode d'emploi ZANUSSI ZGG6420CN
Download
Manual abstract: user guide ZANUSSI ZGG6420CN

Detailed instructions for use are in the User's Guide.

[. . . ] GAS HOBS ZGG 642 ZGG 6420 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB Important Safety Information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 727727 Installation · This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations Current Editions and the IEE Wiring Regulations. For appliances installed in the Republic of Ireland please refer to NSAI-Domestic Gas Installations I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Remove all packaging before using the hob. [. . . ] * Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside European Community (EC) or European Free Trade Area. * * Appliances found to be in use within a commercial or similar environment, plus those which are the subject to rental agreements. Products of Zanussi manufacture which are not marketed by Zanussi. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: * The guarantee starts from the date you first purchased your product. * The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products. * This guarantee relates to you and cannot be transferred to another user. * Your new home is within the European Community (EC) or European Free Trade Area. * The product is installed and used in accordance with our instructions and is only used domestically, i. e. a normal household * The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0) 3 44 62 29 29 Germany Nürnberg +49 (0) 800 234 7378 Italy Pordenone +39 (0) 0434 39 4700 Sweden Stockholm +46 (0) 8 672 53 90 UK Slough +44 (0) 1753 219897 6 Instructions for the Installer Engineers technical data OVERALL DIMENSIONS Width: Depth: 580 mm. 510 mm. Semi-rapid Burner Heat Input 1. 9 kW (6483 BTU/HR) CUT OUT DIMENSIONS Width: Depth: 550 mm. 470 mm. Rapid Burner Heat Input 2. 9 kW Natural Gas (9895 BTU/HR) 2. 7 kW L. P. G. For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S 813 Current Edition Section 7- Permitted Locations of Appliance. Provision for Ventilation The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 600 mm 700 mm 650 mm 400 mm 400 mm 50 m 55 m mm 400 mm 100 mm 50 m 55 m mm 400 mm 100 mm 50 m m 50 m m FO 0812 FO 0813 8 Installation IMPORTANT This hob must be installed by a competent and qualified person only. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. Gas Connection Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. [. . . ] INSULATION CHECK - Appliance electrically disconnected, all switches ON. Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit. If meter reads less than (infinity) there is a fault. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGG6420CN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGG6420CN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag