User manual ZANUSSI ZGG782CTX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZGG782CTX. We hope that this ZANUSSI ZGG782CTX user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZGG782CTX.


Mode d'emploi ZANUSSI ZGG782CTX
Download

You may also download the following manuals related to this product:

   ZANUSSI ZGG782CTX BROCHURE (67 ko)
   ZANUSSI ZGG782CTX DATASHEET (123 ko)

Manual abstract: user guide ZANUSSI ZGG782CTX

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction booklet Gas hob ZGG 782 CT GB Thank you for selecting our appliance We wish you lots of enjoyment with your new appliance and we hope that you will consider our brand again when purchasing household appliances. Please read this user manual carefully and keep it throughout the product life cycle as a reference document. The user manual should be passed on to any future owner of the appliance. 2 Contents Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description of the Hob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] must DISCONNECT the hob from the electricity supply. The hob is best cleaned whilst it is still warm, as spillage can be removed more easily than if it is left to cool. This appliance cannot be cleaned with steam or with a steam cleaning machine. Top The Hob Top Regularly wipe over the hob top using a soft cloth well wrung out in warm water to which a little wasing up liquid has been added. Avoid the use of the following: - household detergent and bleaches; - impregnated pads unsuitable for non-stick saucepans; - steel wool pads; - bath/sink stain removers. Should the hob top become heavily soiled, the following products are recommended: - For stainless steel hobs use a proprietary stainless steel cleaner. - For other hobs use Hob Brite or Bar Keepers Friend. vinegar, Do not leave acid or alkaline substances (e. g. vinegar, salt, lemon juice, etc. ) on the cooktop. If scratches or cracks are noticed on the glass top, immediately disconnect the appliance from the electrical supply, contact your local Service For ce Centr e and avoid supply, Force Centre using the appliance until it has been repaired. The Pan Supports If necessary remove stubborn stains using a paste cleaner. After cleaning, make sure that the pan supports are correctly positioned. 100/mm G30 G31 Auxiliary burner Semi-rapid burner Triple Crown burner 1, 0 1, 9 3, 8 0, 33 0, 45 1, 20 70 96 146 0, 095 0, 181 0, 362 50 71 98 73 138 276 71 136 271 BURNER Auxiliary Semi-rapid Triple Crown Dia. Tap By-pass 1/100 mm 28 32 56 Aeration adjustment none 14 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Provision Ventilation Pr ovision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 100 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I. S. [. . . ] 2) Fit manometer tube over the injector. 3) Turn on the burner gas supply and ignite another burner supply. The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar. 4) Turn off the burner supplies. 25 Conversion from Natural Gas to LPG IMPORT IMPOR TANT The replacement/conversion from natural gas to LPG should only be undertaken by a competent person. It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZGG782CTX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZGG782CTX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag