User manual ZANUSSI ZHC611W1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZHC611W1. We hope that this ZANUSSI ZHC611W1 user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZHC611W1.


Mode d'emploi ZANUSSI ZHC611W1
Download
Manual abstract: user guide ZANUSSI ZHC611W1

Detailed instructions for use are in the User's Guide.

[. . . ] MAINTENANCE · Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. · Clean and/or replace the Filters after the specified time period. · Clean the hood using a damp cloth and a neutral liquid detergent. 13 GB CHARACTERISTICS Technical Characteristics Tender Hood Supply Voltage Supply Frequency Weight 220-240 V 50 Hz ~ 12 kg Motore 6/40K-A 6/50K-A 8BS/28K-A-P PRO Q. ty Insulation Class 1 IIa 1 IIa 1 IIa 1 Ia Power 150 W 190 W 205 W 330 W Dimensions min. 745 132 81 90 240 20 L 210 100 150 650 min. P 360 r. [. . . ] 1 2 2. 1 2. 2 8a 8b 9 15 11 7. 1 12d 12a Ref. 7. 1 7. 2. 1 11 12a 12d 12e Q. ty Product Components 1 Hood Body, complete with: Controls, Light, Blower, Filters 1 Telescopic Chimney comprising: 1 Upper Section 1 Lower Section 1 Right Air Outlet Grill 1 Left Air Outlet Grill 1 Reducer Flange ø 150-120 mm 1 Air Outlet Connection Q. ty 2 2 8 8 2 6 Installation Components Hood Body Fixing Brackets Upper Chimney Section Fixing Brackets Wall Plugs Screws 4. 2 x 44, 4 Screws M4 x 25 Screws 2. 9 x 9. 5 2. 1 2 2. 2 8b 8a 12e 9 1 12e Q. ty Documentation 1 Instruction Manual 15 GB INSTALLATION Wall drilling and bracket fixing 1÷2 650 min. Wall marking: · Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. · Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (height of the visible part of the panel) for installation with the back panel. · Place bracket 7. 2. 1 on the wall as shown about 1-2 mm from the ceiling or upper limit, aligning the centre (notch) with the vertical reference line. · Mark the wall at the centres of the holes in the bracket. · Place bracket 7. 2. 1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. · Mark the wall at the centres of the holes in the bracket. · Place bracket 7. 1 as shown 110 mm from the vertical reference line and 180 mm above the horizontal reference line. · Mark the centres of the holes in the bracket. Switches the extractor motor on and off. Sets the operating speed of the extractor: 1. Low speed, used for a continuous and silent air change in the presence of light cooking vapour. Medium speed, suitable for most operating conditions given the optimum treated air flow/ noise level ratio. Maximum speed, used for eliminating the highest cooking vapour emission, including long periods L S Light Led Switches the lighting system on and off. Switches the extractor motor on and off at low speed. Used to provide a contin-uos and silent air change in the presence of light cooking vapours. Medium speed, suitable for most operating conditions given the optimum treated air flow/noise level ratio. Maximum speed, used for eliminating the highest cooking vapour emission, including long periods. M Motor V Speed V1 Motor V2 Speed V3 Speed 19 GB MAINTENANCE Grease filters CLEANING METAL SELF-SUPPORTING GREASE FILTERS The filters must be cleaned every 2 months of operation, or more frequently with heavy usage, and can be washed in a dishwasher. . · Remove the filters by releasing the fixing hooks. [. . . ] · Wash the filters, taking care not to bend them. · When refitting the filters, make sure that the handle is visible on the outside. Odour filters (Recirculation version) REPLACING THE ACTIVATED CARBON FILTERS These filters are not washable and cannot be regenerated, and must be replaced every 4 months of operation, or more frequently with heavy usage. · Remove the saturated activated charcoal filters as shown (A). · Replace the grease filters. B A GB 20 Lighting LIGHT REPLACEMENT 40 W incandescent light · Remove the metal grease filters. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZHC611W1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZHC611W1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag