User manual ZANUSSI ZHC914XG

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZHC914XG. We hope that this ZANUSSI ZHC914XG user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZHC914XG.


Mode d'emploi ZANUSSI ZHC914XG
Download
Manual abstract: user guide ZANUSSI ZHC914XG

Detailed instructions for use are in the User's Guide.

[. . . ] 5 Installazione del Traliccio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connessione aspirante o filtrante . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allacciamento elettrico alla rete di alimentazione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Montaggio del camino telescopico . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 28 Komponenten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Montageanweisung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Montage des Teleskop-Gerüstes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Abluft- oder Umluftbetrieb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Anschluss an das Stromnetz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Montage des Teleskop-Kamins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Montage des Haubenkörpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Elektroanschluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 BEDIENUNG WARTUNG Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Bedienungsanweisung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Metallfettfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The hood can be used in either extraction mode (ducted to the outside) or in recirculation mode (internal recycling). Safety warnings · Due to the difficulties which could be experienced when installing this hood, because of the specific weight of the product, installation should only be carried out by a qualified or competent technician, in compliance with all the rules concerning the evacuation of contaminated air. The manufacturer declines all responsibility for any damage or injury caused as a result of incorrect installation, poor workmanship or failure to comply with the instructions provided in this manual. · Do not connect the hood ducting to central heating flues, chimneys, etc. . · The minimum safety distance between the cooker top and the hood is 65 cm. · Never do flambé cooking under the hood. · Never leave frying pans unattended during use: overheated fats and oils may ignite. · If the room in which the hood is to be used contains other non-electric appliances (such as gas appliances), ensure that there is an adequate supply of air into the room. When the hood is used in conjunction with other non-electric appliances the negative pressure in the room must not exceed 0. 04 mbar, to prevent fumes from being drawn back into the room by the hood itself. Components · The hood is made up of the following components (fig. 1): n. 1 hood canopy C, complete with controls, worktop illumination and fan unit n. 1 telescopic frame, comprising: n. 1 upper frame section TS n. 1 lower frame section TI n. 1 telescopic chimney stack, comprising: n. 1 upper chimney stack S n. 1 lower chimney stack I n. 1 deflector D n. 2 venting grilles G n. 1 reduction flange Ø 150-120 A n. 1 additional recirculation spigot P n. 2 recirculation clamps F n. 1 valve V (optional) n. 1 recirculation spigot R n. 2 additional recirculation spigots P1 P1 S R D P G V A C I F TI TS T · · · · · · · · · · 12 Fig. · Cavity ceiling with inner space, having a wall thickness of about 20 mm; use, in this case only, the 4 dowels and screws supplied in bag (1). Once fixed, make sure that the base is absolutely stable, even when the metal frame is subjected to lateral stress. [. . . ] For recirculation versions, also check that the venting grilles are properly inserted into clamp R (fig. 4). TS S TS S I G TI 15 Fig. 4 GB Fitting the hood canopy · Fix the hood canopy C to the telescopic frame (fig. 5) using 4 screws M6x10 provided in bag (2). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZHC914XG

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZHC914XG will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag