User manual ZANUSSI ZHC927X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZHC927X. We hope that this ZANUSSI ZHC927X user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZHC927X.


Mode d'emploi ZANUSSI ZHC927X
Download
Manual abstract: user guide ZANUSSI ZHC927X

Detailed instructions for use are in the User's Guide.

[. . . ] · Never use the hood for purposes other than for which it has ben designed. · Never leave high naked flames under the hood when it is in operation. · Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. · Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. [. . . ] · Hook the hood body onto the screws 12a. · Fully tighten support screws 12a. · Adjust screws Vr to level the hood body. Vr 12a GB 16 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. · To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. · Fix the pipe in position using sufficient pipe clamps (not supplied). · Remove any activated charcoal filters. ø 150 9 ø 120 RECIRCULATION VERSION AIR OUTLET · Assemble the two halves of the hood body extension piece 14. · Push fit the assembled hood body extension piece 14 onto the air outlet. · Push fit connection 15 onto the hood body extension piece 14. · Insert the connection extension pieces laterally 14. 1 in connection 15. 15 8b 8a 14 14. 1 · Make sure that the outlet of the extension pieces 14. 1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14. 1 or by cutting the hood body extension 14 along one of the thinner section channels denoting the pre-fixed lengths, then reassemble as described previously. · The air outlet directional grills 8a - 8b must be fitted after the lower outlet duct 2. 2 has been installed. · Ensure that the activated charcoal filters have been inserted. ELECTRICAL CONNECTION · Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. 17 GB Flue assembly Upper exhaust flue · Slightly widen the two sides of the upper flue and hook them behind the brackets 7. 2. 1, making sure that they are well seated. · Secure the sides to the brackets using the 4 screws 12c (2, 9 x 6, 5) supplied. 2. 1 7. 2. 1 12c Lower exhaust flue · Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. · Fix the lower part laterally to the hood body using the 2 screws 12c (2, 9 x 6, 5) supplied. · On the recirculation version, fit the directional grids 8a - 8b in their housings making sure that the directional symbols are towards the top and front of the hood. Also make sure that they are correctly inserted in the connection extension pieces 14. 1. 2 8b 2. 2 8a 12c GB 18 USE Control panel S1 0-1 S2 S3 T1 T2 T3 15 30 0-1 S4 S5 R reset reset L V1 delay 60 V2 V3 V4 V5 T L Light Switches the lighting system on and off. Activated charcoal filter exhausted alarm led. To disable this indicator (Ducted hoods) simultaneously press buttons R (using a sharp object, for example a pencil) and V2. To enable it again, press buttons R and V3. [. . . ] · Extract the Lamp from the Support. · Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. · Replace the Support, fixing it in place with the two Screws removed as above. 21 GB Quest'apparecchio é conforme alla norma europea sulla bassa tensione C. E. E. 73/23 relativa alla sicurezza elettrica e alle norme europee: C. E. E. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZHC927X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZHC927X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag