User manual ZANUSSI ZHC929X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ZANUSSI ZHC929X. We hope that this ZANUSSI ZHC929X user guide will be useful to you.

Lastmanuals help download the user guide ZANUSSI ZHC929X.


Mode d'emploi ZANUSSI ZHC929X
Download
Manual abstract: user guide ZANUSSI ZHC929X

Detailed instructions for use are in the User's Guide.

[. . . ] 1 11 Installation instructions · · · · · For easy installation, proceed as follows: Fix the wall brackets Fix the canopy Electrical connection and working test Ducting or Recirculation fitting Fix the telescopic chimney Fitting the wall brackets Please refer to (fig. 2): · Draw a vertical line on the wall, from the centre of the cooking appliance up to the ceiling, using a marking pen. This is to ensure the correct vertical alignment of the various parts. · Fixing the wall brackets item 2: a) Place one of the brackets 2 against the wall approximately 1 or 2 mm from the ceiling or from the top limit, aligning its centre (slot) with the vertical line. b) Mark the centres of two keyholes in the bracket on the wall. [. . . ] 3 S1 S1 Electrical connection and working test · Before connecting to the mains supply ensure that the mains voltage corresponds with the voltage on the rating plate inside the hood. · Connect the cooker hood to the mains via a double pole switch which has 3 mm clearance between the contacts. · Once the electrical connection has been completed, check that worktop illumination, motor and speed work properly. Fig. 4 1 1 Ducting or Recirculation fitting · Ducting fitting · The hood can be ducted to the outside using either rigid or flexible ducting Ø 120 or 150 mm, the choice of which is left to the installer. When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet (fig. 5). · Cut the additional spigot P in correspondence with outlets 1 and 2 , which must be formed directly on the piece. Connect the additional spigot P to the round fan outlet, pushing it downwards, and fit spigot R to additional spigot P in a similar manner (make sure that the two additional side recirculation spigots P1 are fitted to spigot R). Make sure that the height of the assembly R + P corresponds to the height of the chimney outlet (fig. · If the hood is supplied with the activated charcoal filters fitted, the filters should be removed (see paragraph on Maintenance). 1 Fig. 5 A GB 13 · Recirculation fitting · The filtered air is returned to the room through the two plastic side grills G on the lower chimney element I . · Connect the additional spigot P to the round fan outlet, pushing it downwards, and fit spigot R to additional spigot P in a similar manner (make sure that the two additional side recirculation spigots P1 are fitted to spigot R). Cut the additional spigot P in correspondence with outlets 1 and 2 , which must be formed directly on the piece. Make sure that the height of the assembly R + P corresponds to the height of the chimney outlet. (fig. 6). · Fit the activated charcoal filters inside the canopy (see paragraph on Maintenance ). Do not fit the venting grilles until after the chimney has been installed. P1 P1 Fig. 6 R P G 2 S 2 Fitting the telescopic chimney · To fit the upper section S first expand the two side pieces slightly, hook them behind the brackets 2 and close them together again until they touch. Fix the upper section S to the brackets 2 using four of the screws provided in the bag of accessories (fig. · Fit the lower section I as above, between the upper section S and the canopy C using two of the screws provided in the bag of accessories. · Chimney with venting grilles: Snap the venting grilles into position in the apertures located on the chimney section, so that the symbol is turned upwards and the symbol faces forwards. Also, when the hood is used in recirculation mode, ensure that the grilles are properly secured to the inside of the recirculation spigot R (fig. 8). [. . . ] · Resetting the alarm signal To turn the alarm signal off, proceed as follows: · Turn off the Lights T1 and the Suction Motor T2; · Press the Speed T4 for at least 3 seconds, until the Leds flash in confirmation. In any case the saturated filters alarm will only come into operation when the suction motor is turned on. 73/23 relativa alla sicurezza elettrica e alle norme europee: C. E. E. 89/336 relativa alla compatibilità elettromagnetica e C. E. E. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI ZHC929X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI ZHC929X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag